A comparison of two techniques for inserting the Airtraq™ laryngoscope in morbidly obese patients

被引:38
作者
Dhonneur, G. [1 ]
Ndoko, S. K. [1 ]
Amathieu, R. [1 ]
Attias, A. [1 ]
Housseini, L. E. L. [1 ]
Polliand, C. [1 ]
Tual, L. [1 ]
机构
[1] Jean Verdier Publ Univ Hosp Paris, Dept Anesthesia & Intens Care, APHP, Bondy Paris Sch Med 13, F-93000 Bobigny, France
关键词
D O I
10.1111/j.1365-2044.2007.05128.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We postulated that video-controlled tracheal intubation with the Airtraq((TM)) laryngoscope using the reverse manoeuvre instead of the standard technique of insertion could facilitate the airway management of morbidly obese patients. For the reverse manoeuvre the laryngoscope is inserted 180 degrees opposite to that recommended, and once in place rotated into the conventional pharyngeal position. Eighty (40 lean and 40 morbidly obese) ASA I-III adult patients were randomly allocated to four equal groups to compare the standard technique to the reverse manoeuvre for inserting the Airtraq laryngoscope. Video-controlled and clinical tracheal intubation characteristics were recorded. The reverse manoeuvre did not influence tracheal intubation characteristics in the group of lean patients. In the group of morbidly obese patients, the standard technique of insertion was not satisfactory in 20% of cases and the reverse manoeuvre facilitated, speeded and secured tracheal intubation.
引用
收藏
页码:774 / 777
页数:4
相关论文
共 6 条
[1]  
Brodsky JB, 2003, ANESTH ANALG, V96, P1841, DOI 10.1213/01.ANE.0000063165.15467.1B
[2]   Tracheal intubation using the Airtraq® in morbid obese patients undergoing emergency cesarean delivery [J].
Dhonneur, Gilles ;
Ndoko, Serge ;
Amathieu, Roland ;
el Housseini, Lodfi ;
Poncelet, Christophe ;
Tual, Loic .
ANESTHESIOLOGY, 2007, 106 (03) :629-630
[3]  
Iked N, 2001, Rev Stomatol Chir Maxillofac, V102, P305
[4]   Cephalometric comparison of pharyngeal changes in subjects with upper airway resistance syndrome or obstructive sleep apnoea in upright and supine positions [J].
Ingman, T ;
Nieminen, T ;
Hurmerinta, K .
EUROPEAN JOURNAL OF ORTHODONTICS, 2004, 26 (03) :321-326
[5]   A comparison of tracheal intubation using the Airtraq® or the Macintosh laryngoscope in routine airway management:: a randomised, controlled clinical trial [J].
Maharaj, C. H. ;
O'Croinin, D. ;
Curley, G. ;
Harte, B. H. ;
Laffey, J. G. .
ANAESTHESIA, 2006, 61 (11) :1093-1099
[6]   Evaluation of intubation using the Airtraq® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy -: a manikin study [J].
Maharaj, CH ;
Higgins, BD ;
Harte, BH ;
Laffey, JG .
ANAESTHESIA, 2006, 61 (05) :469-477