Internal fixation of scaphoid non-union: a comparative study of three methods

被引:59
作者
Christodoulou, LS [1 ]
Kitsis, CK [1 ]
Chamberlain, ST [1 ]
机构
[1] Derbyshire Royal Infirm, Pulvertaft Hand Ctr, Derby DE1 2QY, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2001年 / 32卷 / 08期
关键词
D O I
10.1016/S0020-1383(01)00018-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In this study we compared the results of three methods of fixation for scaphoid non-union. The implants used were the AO 2 mm mini-fragment screw, the Herbert screw and the Kirschner (K) wires. Between 1990 and 1999, 132 patients underwent surgery for scaphoid fractures. We used the modified Filan and Herbert classification. Patients with acute fractures and patients requiring vascularised bone grafts were excluded. Twenty-six non-unions were fixed with an AO mini-fragment screw, 58 with a Herbert screw, and nine with K-wires. Radiological union was achieved in 85% of cases using the AO screw, 77% using the Herbert screw and 55% using the K-wire fixation. Statistically there was no significant difference between the AO and Herbert screw groups in terms of rate and speed of radiological union. The mechanical strength of the implant and the compression achieved did not seem to influence the union rate and speed. The type of bone graft (iliac crest or distal radius) did not significantly affect the union rates. Finally, K-wire fixation, either as a primary method or as a salvage procedure, produced inferior results and required prolonged immobilisation in plaster. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:625 / 630
页数:6
相关论文
共 16 条
[1]   20TH QUESTIONS ABOUT SCAPHOID FRACTURES [J].
BARTON, NJ .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (03) :289-310
[2]   Internal fixation of scaphoid fractures with an AO mini-fragment lag screw, using temporary interoperative AO mini external fixation [J].
Christodoulou, L ;
Chamberlain, ST .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1999, 24B (06) :676-678
[3]   RADIOGRAPHIC SIGNS OF UNION OF SCAPHOID FRACTURES - AN ANALYSIS OF INTER-OBSERVER AGREEMENT AND REPRODUCIBILITY [J].
DIAS, JJ ;
TAYLOR, M ;
THOMPSON, J ;
BRENKEL, IJ ;
GREGG, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02) :299-301
[4]   ANTERIOR BONE-GRAFTING AND CONVENTIONAL LAG SCREW FIXATION TO TREAT SCAPHOID NONUNIONS [J].
FERNANDEZ, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :140-147
[5]   A TECHNIQUE FOR ANTERIOR WEDGE-SHAPED GRAFTS FOR SCAPHOID NONUNIONS WITH CARPAL INSTABILITY [J].
FERNANDEZ, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1984, 9A (05) :733-737
[6]   Herbert screw fixation of scaphoid fractures [J].
Filan, SL ;
Herbert, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :519-529
[7]   MANAGEMENT OF THE FRACTURED SCAPHOID USING A NEW BONE SCREW [J].
HERBERT, TJ ;
FISHER, WE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (01) :114-123
[8]   THE HERBERT BONE SCREW - A 10 YEAR PERSPECTIVE [J].
HERBERT, TJ ;
FISHER, WE ;
LEICESTER, AW .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (04) :415-419
[9]  
Herbert TJ., 1990, FRACTURED SCAPHOID