Microgel reinforced zwitterionic hydrogel coating for blood-contacting biomedical devices

被引:142
|
作者
Yao, Mengmeng [1 ,2 ,3 ]
Wei, Zhijian [4 ,5 ,6 ]
Li, Junjin [4 ,5 ,6 ]
Guo, Zhicheng [1 ]
Yan, Zhuojun [1 ]
Sun, Xia [1 ]
Yu, Qingyu [1 ]
Wu, Xiaojun [1 ]
Yu, Chaojie [1 ]
Yao, Fanglian [1 ,2 ,3 ,7 ]
Feng, Shiqing [4 ,5 ,6 ]
Zhang, Hong [1 ,2 ,3 ]
Li, Junjie [1 ,2 ,3 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Frontiers Sci Ctr Synthet Biol, Tianjin 300350, Peoples R China
[3] Tianjin Univ, Key Lab Syst Bioengn, Minist Educ, Tianjin 300350, Peoples R China
[4] Tianjin Med Univ, Dept Orthoped Surg, Int Sci & Technol Cooperat Base Spinal Cord Injur, Gen Hosp, Tianjin, Peoples R China
[5] Shandong Univ, Qilu Hosp, Cheeloo Coll Med, Dept Orthopaed, Jinan 250012, Shandong, Peoples R China
[6] Shandong Univ, Ctr Orthopaed, Cheeloo Coll Med, Jinan 250012, Shandong, Peoples R China
[7] East China Jiaotong Univ, Sch Mat Sci & Engn, Nanchang 330013, Jiangxi, Peoples R China
关键词
THROMBOSIS; POLYMERS; TOUGH;
D O I
10.1038/s41467-022-33081-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Zwitterionic hydrogels are nonfouling and hemocompatibility but several key challenges such as weak mechanical strength and low adhesion hamper their application as coating materials for devices. Here, the authors report a microgel reinforced zwitterionic hydrogel with excellent mechanical robustness and anti-swelling properties. Zwitterionic hydrogels exhibit eminent nonfouling and hemocompatibility. Several key challenges hinder their application as coating materials for blood-contacting biomedical devices, including weak mechanical strength and low adhesion to the substrate. Here, we report a poly(carboxybetaine) microgel reinforced poly(sulfobetaine) (pCBM/pSB) pure zwitterionic hydrogel with excellent mechanical robustness and anti-swelling properties. The pCBM/pSB hydrogel coating was bonded to the PVC substrate via the entanglement network between the pSB and PVC chain. Moreover, the pCBM/pSB hydrogel coating can maintain favorable stability even after 21 d PBS shearing, 0.5 h strong water flushing, 1000 underwater bends, and 100 sandpaper abrasions. Notably, the pCBM/pSB hydrogel coated PVC tubing can not only mitigate the foreign body response but also prevent thrombus formation ex vivo in rats and rabbits blood circulation without anticoagulants. This work provides new insights to guide the design of pure zwitterionic hydrogel coatings for biomedical devices.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design of nonthrombogenic polymer surfaces for blood-contacting medical devices
    Kim, SW
    Jacobs, H
    BLOOD PURIFICATION, 1996, 14 (05) : 357 - 372
  • [22] A biostable, anti-fouling zwitterionic polyurethane-urea based on PDMS for use in blood-contacting medical devices
    Kim, Seungil
    Ye, Sang-ho
    Adamo, Arianna
    Orizondo, Ryan A.
    Jo, Jaehyuk
    Cho, Sung Kwon
    Wagner, William R.
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (36) : 8305 - 8314
  • [23] Progress on Self-Adaptive Surface of Blood-Contacting Biomedical Polymer
    Shi Q.
    Guan X.
    Ma Z.
    Hou J.
    Xiang Z.
    Yin J.
    Yin, Jinghua (yinjh@ciac.ac.cn), 1600, Sichuan University (37): : 230 - 237
  • [24] Dressing Blood-Contacting Materials by a Stable Hydrogel Coating with Embedded Antimicrobial Peptides for Robust Antibacterial and Antithrombus Properties
    Liu, Kunpeng
    Zhang, Fanjun
    Wei, Yuan
    Hu, Qinsheng
    Luo, Qingfeng
    Chen, Chong
    Wang, Jingyu
    Yang, Li
    Luo, Rifang
    Wang, Yunbing
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (33) : 38947 - 38958
  • [25] Performance of a Hydrogel Coated Nitinol with Oligonucleotide-Modified Nanoparticles Within Turbulent Conditions of Blood-Contacting Devices
    Watson, Connor
    Abune, Lidya
    Saaid, Hicham
    Wen, Connie
    Wang, Yong
    Manning, Keefe B.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (02) : 239 - 251
  • [26] Performance of a Hydrogel Coated Nitinol with Oligonucleotide-Modified Nanoparticles Within Turbulent Conditions of Blood-Contacting Devices
    Connor Watson
    Lidya Abune
    Hicham Saaid
    Connie Wen
    Yong Wang
    Keefe B. Manning
    Cardiovascular Engineering and Technology, 2023, 14 : 239 - 251
  • [27] Polysaccharide-based bioactive adsorbents for blood-contacting implant devices
    Ana Lorena de Brito Soares
    Marcella Torres Maia
    Sandy Danielle Lucindo Gomes
    Thamyres Freire da Silva
    Rodrigo Silveira Vieira
    Brazilian Journal of Chemical Engineering, 2022, 39 : 1033 - 1046
  • [28] Phosphorylcholine- and cation-bearing copolymer coating with superior antibiofilm and antithrombotic properties for blood-contacting devices
    Zhang, Fanjun
    Yang, Li
    Hu, Cheng
    Li, Linhua
    Wang, Jingyu
    Luo, Rifang
    Wang, Yunbing
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (36) : 8433 - 8443
  • [29] A honokiol-mediated robust coating for blood-contacting devices with anti-inflammatory, antibacterial and antithrombotic properties
    Li, Linhua
    Chen, Chong
    Zhang, Chunle
    Luo, Rifang
    Lan, Xiaorong
    Guo, Fan
    Ma, Liang
    Fu, Ping
    Wang, Yunbing
    JOURNAL OF MATERIALS CHEMISTRY B, 2021, 9 (47) : 9770 - 9783
  • [30] Polysaccharide-based bioactive adsorbents for blood-contacting implant devices
    de Brito Soares, Ana Lorena
    Maia, Marcella Torres
    Lucindo Gomes, Sandy Danielle
    da Silva, Thamyres Freire
    Vieira, Rodrigo Silveira
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2022, 39 (04) : 1033 - 1046