Determination of tranexamic acid concentration by solid phase microextraction and liquid chromatography-tandem mass spectrometry: First step to in vivo analysis

被引:37
|
作者
Bojko, Barbara [1 ]
Vuckovic, Dajana [1 ]
Cudjoe, Erasmus [1 ]
Hoque, Md Ehsanul [1 ]
Mirnaghi, Fatemeh [1 ]
Wasowicz, Marcin [2 ]
Jerath, Angela [2 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Toronto Gen Hosp, Dept Anesthesia, Toronto, ON M5G 2C4, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 32期
基金
加拿大自然科学与工程研究理事会;
关键词
Solid phase microextraction; Liquid chromatography; Tandem mass spectrometry; Tranexamic acid; Cardiopulmonary bypass; Plasma; CARDIOPULMONARY BYPASS; BIOLOGICAL-FLUIDS; PROTEIN-BINDING; SERUM SAMPLES; BETA-BLOCKERS; HUMAN PLASMA; BLOOD; URINE; BIOANALYSIS; RECEPTOR;
D O I
10.1016/j.jchromb.2011.08.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid phase microextraction (SPME) method followed by LC-MS/MS analysis was developed to determine the concentration of tranexamic acid (TA) in plasma. The use of a new biocompatible C18 coating allowed the direct extraction from complex biological samples without prior sample preparation; no matrix effect was observed. The results revealed that SPME was suitable for the analysis of polar drugs such as TA; such an application was previously inaccessible because of the limited availability of SPME coatings that can extract polar molecules. The proposed method was validated according to the bioanalytical method validation guidelines. LOD and LLOQ were 0.5 and 1.5 mu g/ml, respectively. The recovery for the method was 0.19%, and the accuracy and precision of the method were <9 and <11%, respectively, with the exception of LLOQ, where the values were <16 and <13%, respectively. The performance of the proposed method was also compared against that of the standard techniques of protein precipitation and ultrafiltration. A statistical analysis indicated a clinically significant agreement among all assays. Another advantage of SPME over conventional techniques was the easy automation and feasibility of in vivo analysis; this advantage makes it possible to use the proposed method for an on-site analysis in clinical practice. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3781 / 3787
页数:7
相关论文
共 50 条
  • [31] Therapeutic Monitoring of Tranexamic Acid Concentration: High-Throughput Analysis With Solid-Phase Microextraction
    Bojko, Barbara
    Vuckovic, Dajana
    Mirnaghi, Fatemeh
    Cudjoe, Erasmus
    Wasowicz, Marcin
    Jerath, Angela
    Pawliszyn, Janusz
    THERAPEUTIC DRUG MONITORING, 2012, 34 (01) : 31 - 37
  • [32] In vivo solid-phase microextraction liquid chromatography-tandem mass spectrometry for monitoring blood eicosanoids time profile after lipopolysaccharide-induced inflammation in Sprague-Dawley rats
    Bessonneau, Vincent
    Zhan, Yanwei
    De Lannoy, Ines A. M.
    Saldivia, Victor
    Pawliszyn, Janusz
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 134 - 138
  • [33] Determination of bronchoalveolar lavage bile acids by solid phase microextraction liquid chromatography-tandem mass spectrometry in combination with metabolite profiling: Comparison with enzymatic assay
    Bessonneau, Vincent
    Bojko, Barbara
    Azad, Azar
    Keshavjee, Shalf
    Azad, Sassan
    Pawliszyn, Janusz
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1367 : 33 - 38
  • [34] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Wang, Dongli
    Stapleton, Heather M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1831 - 1839
  • [35] Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Du Ping
    Li Peng-Fei
    Liu Hong-Chuan
    Yu Wei-Yue
    Liu Li-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) : 876 - 881
  • [36] Hollow fiber liquid phase microextraction combined with liquid chromatography-tandem mass spectrometry for the analysis of emerging contaminants in water samples
    Salvatierra-stamp, Vilma
    Muniz-Valencia, Roberto
    Jurado, Jose M.
    Ceballos-Magana, Silvia G.
    MICROCHEMICAL JOURNAL, 2018, 140 : 87 - 95
  • [37] Analysis of cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry
    Fabritius, Marie
    Staub, Christian
    Mangin, Patrice
    Giroud, Christian
    FORENSIC TOXICOLOGY, 2013, 31 (01) : 151 - 163
  • [38] Determination of 115 Pesticide Residues in Textiles by Liquid Chromatography-Tandem Mass Spectrometry
    Li, Ying
    Ye, Xiwen
    Luo, Xin
    Zhu, Wenxuan
    Tang, Zhixu
    Niu, Zengyuan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2025, 39 (09)
  • [39] An on-line solid phase extraction procedure for the routine quantification of urinary methylmalonic acid by liquid chromatography-tandem mass spectrometry
    Kirchhoff, Fabian
    Lorenzl, Stephan
    Vogeser, Michael
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (11) : 1647 - 1650
  • [40] Determination of methocarbamol concentration in human plasma by high performance liquid chromatography-tandem mass spectrometry
    Zha, Wuyi
    Zhu, Zhimeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (9-10): : 831 - 835