Determination of tranexamic acid concentration by solid phase microextraction and liquid chromatography-tandem mass spectrometry: First step to in vivo analysis

被引:37
|
作者
Bojko, Barbara [1 ]
Vuckovic, Dajana [1 ]
Cudjoe, Erasmus [1 ]
Hoque, Md Ehsanul [1 ]
Mirnaghi, Fatemeh [1 ]
Wasowicz, Marcin [2 ]
Jerath, Angela [2 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Toronto Gen Hosp, Dept Anesthesia, Toronto, ON M5G 2C4, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 32期
基金
加拿大自然科学与工程研究理事会;
关键词
Solid phase microextraction; Liquid chromatography; Tandem mass spectrometry; Tranexamic acid; Cardiopulmonary bypass; Plasma; CARDIOPULMONARY BYPASS; BIOLOGICAL-FLUIDS; PROTEIN-BINDING; SERUM SAMPLES; BETA-BLOCKERS; HUMAN PLASMA; BLOOD; URINE; BIOANALYSIS; RECEPTOR;
D O I
10.1016/j.jchromb.2011.08.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid phase microextraction (SPME) method followed by LC-MS/MS analysis was developed to determine the concentration of tranexamic acid (TA) in plasma. The use of a new biocompatible C18 coating allowed the direct extraction from complex biological samples without prior sample preparation; no matrix effect was observed. The results revealed that SPME was suitable for the analysis of polar drugs such as TA; such an application was previously inaccessible because of the limited availability of SPME coatings that can extract polar molecules. The proposed method was validated according to the bioanalytical method validation guidelines. LOD and LLOQ were 0.5 and 1.5 mu g/ml, respectively. The recovery for the method was 0.19%, and the accuracy and precision of the method were <9 and <11%, respectively, with the exception of LLOQ, where the values were <16 and <13%, respectively. The performance of the proposed method was also compared against that of the standard techniques of protein precipitation and ultrafiltration. A statistical analysis indicated a clinically significant agreement among all assays. Another advantage of SPME over conventional techniques was the easy automation and feasibility of in vivo analysis; this advantage makes it possible to use the proposed method for an on-site analysis in clinical practice. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3781 / 3787
页数:7
相关论文
共 50 条
  • [21] Solid Phase Microextraction/Gas Chromatography-Tandem Mass Spectrometry for Determination of Polycyclic Aromatic Hydrocarbons in Fine Aerosol in Beijing
    Liu Fei
    Duan Feng-Kui
    Li Hai-Rong
    Ma Yong-Liang
    He Ke-Bin
    Zhang Qian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (04) : 540 - 546
  • [22] Determination of penicillic acid in cereals by solid-phase extraction and gas chromatography-tandem mass spectrometry
    Yu, Zuolong
    Hu, Beizhen
    Chen, Yao
    Huang, Chaoqun
    Han, Chao
    Shen, Yan
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 130
  • [23] A multi-fiber handling device for in vivo solid phase microextraction-liquid chromatography-mass spectrometry applications
    Cudjoe, Erasmus
    Pawliszyn, Janusz
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1232 : 77 - 83
  • [24] Determination of multi-class pesticides in wines by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Economou, Anastasios
    Botitsi, Helen
    Antoniou, Spyros
    Tsipi, Despina
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (31) : 5856 - 5867
  • [25] Aptamer-functionalized solid phase microextraction-liquid chromatography/tandem mass spectrometry for selective enrichment and determination of thrombin
    Du, Fuyou
    Alam, Md Nazmul
    Pawliszyn, Janusz
    ANALYTICA CHIMICA ACTA, 2014, 845 : 45 - 52
  • [26] Determination of opiates in whole blood using microextraction by packed sorbent and gas chromatography-tandem mass spectrometry
    Prata, Margarida
    Ribeiro, Andreia
    Figueirinha, David
    Rosado, Tiago
    Oppolzer, David
    Restolho, Jose
    Araujo, Andre R. T. S.
    Costa, Suzel
    Barroso, Mario
    Gallardo, Eugenia
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 1 - 10
  • [27] Liquid chromatography-tandem mass spectrometry method for determination of total and free teriflunomide concentration in serum of patients with multiple sclerosis
    Pesakova, Veronika
    Brozmanova, Hana
    Sistik, Pavel
    Kusnirikova, Zuzana
    Kacirova, Ivana
    Grundmann, Milan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 224
  • [28] Liquid chromatography coupled to tandem mass spectrometry for the analysis of inositol hexaphosphate after solid-phase extraction
    Rougemont, Blandine
    Fonbonne, Catherine
    Lemoine, Jerome
    Bourgeaux, Vanessa
    Salvador, Arnaud
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2016, 39 (08) : 408 - 414
  • [29] Determination of synthetic hallucinogens in oral fluids by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry
    Lesne, Evan
    Munoz-Bartual, Miguel
    Esteve-Turrillas, Francesc A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (17) : 3607 - 3617
  • [30] In Vivo Detection of Tetrodotoxin in Takifugu obscurus Based on Solid-Phase Microextraction Coupled with Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Meng, Hengli
    Jiang, Shui
    Zhang, Yin
    Hu, Yun
    Liu, Yuan
    MOLECULES, 2022, 27 (18):