摘要
This paper presents observations on the identified modal properties of two tall buildings using ambient vibration data collected during strong wind events. A recently developed fast Bayesian frequency domain method is used for modal identification based on the measured ambient data. The approach views modal identification as an inference problem where probability is used as a measure for the relative plausibility of outcomes given a model of the structure and measured data. Focusing on the first three modes, the modal properties of the buildings are identified on non-overlapping time windows during the strong wind events, spanning periods of normal to high wind speeds. Investigation of the identified natural frequencies and damping ratios versus the modal root-mean-square value indicates a significant trend that is statistically repeatable across events. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 28 条
[21]   In-construction vibration monitoring of a super-tall structure using a long-range wireless sensing system [J].
Ni, Y. Q. ;
Li, B. ;
Lam, K. H. ;
Zhu, D. P. ;
Wang, Y. ;
Lynch, J. P. ;
Law, K. H. .
SMART STRUCTURES AND SYSTEMS, 2011, 7 (02) :83-102
[22]   Health Checks through Landmark Bridges to Sky-high Structures [J].
Ni, Y. Q. ;
Wong, K. Y. ;
Xia, Y. .
ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (01) :103-119
[23]   Stochastic system identification for operational modal analysis: A review [J].
Peeters, B ;
De Roeck, G .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2001, 123 (04) :659-667
[24]   Damping evaluation using full-scale data of buildings in Japan [J].
Satake, N ;
Suda, K ;
Arakawa, T ;
Sasaki, A ;
Tamura, Y .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (04) :470-477
[25]   Evaluation of amplitude-dependent damping and natural frequency of buildings during strong winds [J].
Tamura, Y ;
Suganuma, SY .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 59 (2-3) :115-130
[26]   WIND RESPONSE OF A TOWER (TYPHOON OBSERVATION AT THE NAGASAKI HUIS TEN BOSCH DOMTOREN) [J].
TAMURA, Y ;
SHIMADA, K ;
HIBI, K .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1993, 50 (1-3) :309-318
[27]  
Tamura Y., 1994, ASCE STRUCT C IASS I, V2, P1012
[28]  
Yuen KV., 2003, ADV STRUCTURAL ENG, V6, P81, DOI [DOI 10.1260/136943303769013183, 10.1260/136943303769013183]