Longitudinal evaluation of morphometric X-ray absorptiometry for the identification of vertebral deformities

被引:8
作者
Ferrar, L [1 ]
Jiang, G [1 ]
Eastell, R [1 ]
机构
[1] Univ Sheffield, Div Clin Sci, Bone Metab Grp, Metab Sect, Sheffield S10 2TN, S Yorkshire, England
关键词
absorptiometry; deformity; osteoporosis; precision; radiography; vertebrae;
D O I
10.1007/s001980170066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Morphometric X-ray absorptiometry (MXA) has not been evaluated for the identification of incident vertebral deformities. The reliability of longitudinal measurements in quantitative vertebral morphometry is influenced by the precision of the technique. Long-term precision in vitro (weekly MXA phantom scans) assessed by retrospective cumulative sum (Cusum) analysis, detected one event during a 6-month period when the measurement process was 'out of control'. Inspection of service records revealed that repair work was performed around this timepoint. The coefficient of variation (CV) for long-term precision (vertebral heights) in a population-based sample of postmenopausal women ages 56 to 83, mean 65 +/- 6 years (n = 48), was 4.0% for morphometric radiography (MRX), 2.9% for MXA using the compare facility for analysis of serial scans, and 3.2% when 'compare' was not used. In women with osteoporosis ages 49 to 87, mean 67 +/- 9 years (n = 50), the CV was 5.0% for MRX, 4.1% for MXA using 'compare' and 8.5% without 'compare'. Precision errors for height ratios (MRX and MXA) were greater than for vertebral heights. Incident deformities were identified by MRX and MXA in the women with osteoporosis, using point prevalence, 20% minimum reduction in vertebral height, and percent least significant change (LSC) in vertebral heights and height ratios. Semiquantitative analysis of radiographs by a radiologist (Genant method) was used as the gold standard. The results were similar for MRX and MXA, and all morphometric criteria identified a similar proportion of true incident deformities, although the false positive rate was generally greater for the height ratio approaches. MXA has good long-term precision and is comparable to MRX for the identification of incident deformities when scans are analyzed with the compare facility.
引用
收藏
页码:661 / 671
页数:11
相关论文
共 20 条
[1]   Defining incident vertebral deformity: A prospective comparison of several approaches [J].
Black, DM ;
Palermo, L ;
Nevitt, MC ;
Genant, HK ;
Christensen, L ;
Cummings, SR .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (01) :90-101
[2]  
Chappard C, 1998, BRIT J RHEUMATOL, V37, P496
[3]  
EASTELL R, 1996, OSTEOPOROSIS INT S, V2, pS3
[4]   Identification of vertebral deformities in women: Comparison of radiological assessment and quantitative morphometry using morphometric radiography and morphometric X-ray absorptiometry [J].
Ferrar, L ;
Jiang, G ;
Barrington, NA ;
Eastell, R .
JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (03) :575-585
[5]  
FERRAR L, 1998, BONE, V23, pS605
[6]   DXA longitudinal quality control: A comparison of inbuilt quality assurance, visual inspection, multi-rule Shewhart charts and Cusum analysis [J].
Garland, SW ;
Lees, B ;
Stevenson, JC .
OSTEOPOROSIS INTERNATIONAL, 1997, 7 (03) :231-237
[7]   VERTEBRAL FRACTURE ASSESSMENT USING A SEMIQUANTITATIVE TECHNIQUE [J].
GENANT, HK ;
WU, CY ;
VANKUIJK, C ;
NEVITT, MC .
JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 (09) :1137-1148
[8]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[9]  
Lu Y, 1996, J BONE MINER RES, V11, P626
[10]   THE ASSESSMENT OF VERTEBRAL DEFORMITY - A METHOD FOR USE IN POPULATION STUDIES AND CLINICAL-TRIALS [J].
MCCLOSKEY, EV ;
SPECTOR, TD ;
EYRES, KS ;
FERN, ED ;
OROURKE, N ;
VASIKARAN, S ;
KANIS, JA .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (03) :138-147