A kinematic model for calculating cup alignment error during total hip arthroplasty

被引:24
|
作者
Wolf, A [1 ]
DiGioia, AM [1 ]
Mor, AB [1 ]
Jaramaz, B [1 ]
机构
[1] Western Penn Hosp, ICAOS, Inst Comp Assisted Orthoped Surg, Pittsburgh, PA 15217 USA
关键词
hip arthroplasty; cup alignment error Kinematic model; anterior pelvic plane axes; pelvic biomechanics;
D O I
10.1016/j.jbiomech.2004.09.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Reduced range of motion, prosthetic impingement, and joint dislocation can all result from misalignment of the acetabular component (i.e. cup alignment) in patients undergoing total hip arthroplasty. Most methods for acetabular component alignment are designed to provide 45-50 degrees abduction and 15-25 degrees of operative anteversion (also known as flexion) with respect to the anterior pelvic plane coordinate system. Yet in most cases, this coordinate system is not assigned properly, due to differences in patient anatomy and improper positioning in the operating room. This misalignment can result in an error in the cup alignment, which can cause the above-mentioned consequences. This work presents a complete mathematical formulation for the analysis of the inaccuracies related to the anterior pelvic plane axes (APPA) definition and their effect on final cup orientation. We do this by introducing a method taken from Kinematics of Mechanisms, and by representing the errors in the APPA as three concurrent axes of rotation, followed by the version and abduction rotations which are defined relative to the previous rotations. We also present a sensitivity analysis of the results by introducing differential changes between sequential coordinate frames, which simulates the errors in the APPA and their effect on cup orientation. Finally, we demonstrate a computational method which provides corrected version and abduction angles to achieve the desired cup orientation, given that the actual measurement errors are known. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2257 / 2265
页数:9
相关论文
共 50 条
  • [41] Is the Acetabular Cup Orientation Different in Robot-Assisted and Conventional Total Hip Arthroplasty With Right-Handed Surgeons Using an Anterolateral Approach?
    Kara, Gokhan Kursat
    Turan, Kayhan
    Eroglu, Osman Nuri
    Ozturk, Cagatay
    Ertuerer, Erden
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [42] Gait analysis following release of the short external rotators during an anterior approach for total hip arthroplasty
    Petis, Stephen M.
    Vasarhelyi, Edward M.
    Howard, James L.
    Lanting, Brent A.
    HIP INTERNATIONAL, 2018, 28 (06) : 584 - 590
  • [43] The changes in health-related quality of life and related factors during the process of total hip arthroplasty
    Montin, Liisa
    Suominen, Tarja
    Haaranen, Ella
    Katajisto, Jouko
    Lepisto, Jyri
    Leino-Kilpi, Helena
    INTERNATIONAL JOURNAL OF NURSING PRACTICE, 2011, 17 (01) : 19 - 26
  • [44] Measuring leg Length and offset with an imageless navigation system during total hip arthroplasty: is it really accurate?
    Renkawitz, Tobias
    Schuster, Tibor
    Herold, Thomas
    Goessmann, Holger
    Sendtner, Ernst
    Grifka, Joachim
    Kalteis, Thomas
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 192 - 197
  • [45] Spectral analysis of the sound produced during femoral broaching and implant insertion in uncemented total hip arthroplasty
    Whitwell, George
    Brockett, Claire L.
    Young, Steve
    Stone, Martin
    Stewart, Todd D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H2) : 175 - 180
  • [46] Incorporating Functional Strength Integration Techniques During Total Hip Arthroplasty Rehabilitation: A Randomized Controlled Trial
    Judd, Dana L.
    Cheuy, Victor
    Peters, Amy
    Graber, Jeremy
    Hinrichs-Kinney, Lauren
    Forster, Jeri E.
    Christiansen, Cory L.
    Stevens-Lapsley, Jennifer E.
    PHYSICAL THERAPY, 2024, 104 (03):
  • [47] Incarcerated Cannulated Cancellous Screw Removal during Total Hip Arthroplasty with a Novel Trick: A Case Report
    Tomar, L.
    Govil, G.
    Dhawan, P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (01) : 128 - 131
  • [48] Biomechanical evaluation of retrograde docking nailing to a total hip arthroplasty stem in a periprosthetic femur fracture model
    Lenz, Mark
    Hofmann-Fliri, Ladina
    Kasper, Lena Anna
    Varga, Peter
    Zderic, Ivan
    Gehweiler, Dominic
    Klos, Kajetan
    Hofmann, Gunther O.
    Stoffel, Karl
    Gueorguiev, Boyko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (01): : 53 - 59
  • [49] Does body mass index affect restoration of femoral offset, leg length and cup positioning after total hip arthroplasty? A prospective cohort study
    Al-Amiry, Bariq
    Pantelakis, Georgios
    Mahmood, Sarwar
    Kadum, Bakir
    Brismar, Torkel B.
    Sayed-Noor, Arkan S.
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [50] Does body mass index affect restoration of femoral offset, leg length and cup positioning after total hip arthroplasty? A prospective cohort study
    Bariq Al-Amiry
    Georgios Pantelakis
    Sarwar Mahmood
    Bakir Kadum
    Torkel B. Brismar
    Arkan S. Sayed-Noor
    BMC Musculoskeletal Disorders, 20