A kinematic model for calculating cup alignment error during total hip arthroplasty

被引:24
|
作者
Wolf, A [1 ]
DiGioia, AM [1 ]
Mor, AB [1 ]
Jaramaz, B [1 ]
机构
[1] Western Penn Hosp, ICAOS, Inst Comp Assisted Orthoped Surg, Pittsburgh, PA 15217 USA
关键词
hip arthroplasty; cup alignment error Kinematic model; anterior pelvic plane axes; pelvic biomechanics;
D O I
10.1016/j.jbiomech.2004.09.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Reduced range of motion, prosthetic impingement, and joint dislocation can all result from misalignment of the acetabular component (i.e. cup alignment) in patients undergoing total hip arthroplasty. Most methods for acetabular component alignment are designed to provide 45-50 degrees abduction and 15-25 degrees of operative anteversion (also known as flexion) with respect to the anterior pelvic plane coordinate system. Yet in most cases, this coordinate system is not assigned properly, due to differences in patient anatomy and improper positioning in the operating room. This misalignment can result in an error in the cup alignment, which can cause the above-mentioned consequences. This work presents a complete mathematical formulation for the analysis of the inaccuracies related to the anterior pelvic plane axes (APPA) definition and their effect on final cup orientation. We do this by introducing a method taken from Kinematics of Mechanisms, and by representing the errors in the APPA as three concurrent axes of rotation, followed by the version and abduction rotations which are defined relative to the previous rotations. We also present a sensitivity analysis of the results by introducing differential changes between sequential coordinate frames, which simulates the errors in the APPA and their effect on cup orientation. Finally, we demonstrate a computational method which provides corrected version and abduction angles to achieve the desired cup orientation, given that the actual measurement errors are known. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2257 / 2265
页数:9
相关论文
共 50 条
  • [1] Cup positioning in total hip arthroplasty
    Scheerlinck, Thierry
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 336 - 347
  • [2] Kinematic alignment technique for total hip and knee arthroplasty: the personalized implant positioning surgery
    Riviere, Charles
    Lazic, Stefan
    Villet, Loic
    Wiart, Yann
    Allwood, Sarah Muirhead
    Cobb, Justin
    EFORT OPEN REVIEWS, 2018, 3 (03): : 98 - 105
  • [3] A device to make the pelvic sagittal plane horizontal and reduce error in cup inclination during total hip arthroplasty: a validation study
    McMahon, Samuel E.
    Magill, Paul
    Bopf, Daniel P.
    Beverland, David E.
    HIP INTERNATIONAL, 2018, 28 (05) : 473 - 477
  • [4] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Popescu, Dragos
    Gallart, X.
    Garcia, S.
    Bori, G.
    Tomas, X.
    Riba, J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 783 - 785
  • [5] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Dragos Popescu
    X. Gallart
    S. Garcia
    G. Bori
    X. Tomas
    J. Riba
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 783 - 785
  • [6] Change in Spinal Alignment after Total Hip Arthroplasty
    Radcliff, Kristen E.
    Orozco, Fabio
    Molby, Nicholas
    Delasotta, Lawrence
    Chen, Eric
    Post, Zachary
    Ong, Alvin
    ORTHOPAEDIC SURGERY, 2013, 5 (04) : 261 - 265
  • [7] Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    Marx, Axel
    von Knoch, Marius
    Pfoertner, Joerg
    Wiese, Matthias
    Saxler, Guido
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (07) : 487 - 492
  • [8] Effects of acetabular abduction on cup wear rates in total hip arthroplasty
    Del Schutte, H
    Lipman, AJ
    Bannar, SM
    Livermore, JT
    Ilstrup, D
    Morrey, BF
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 621 - 626
  • [9] Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    Axel Marx
    Marius von Knoch
    Jörg Pförtner
    Matthias Wiese
    Guido Saxler
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 487 - 492
  • [10] Total Hip Arthroplasty Patients With Fixed Spinopelvic Alignment Are at Higher Risk of Hip Dislocation
    Esposito, Christina I.
    Carroll, Kaitlin M.
    Sculco, Peter K.
    Padgett, Douglas E.
    Jerabek, Seth A.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05): : 1449 - 1454