Mandibular canal visibility using a plain volumetric interpolated breath-hold examination sequence in MRI

被引:7
|
作者
Deepho, Chutamas [1 ,2 ]
Watanabe, Hiroshi [1 ]
Sakamoto, Junichiro [1 ]
Kurabayashi, Tohru [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Oral & Maxillofacial Radiol, Tokyo, Japan
[2] Naresuan Univ, Dept Oral Diag, Fac Dent, Phitsanulok, Thailand
基金
日本学术振兴会;
关键词
magnetic resonance imaging; mandible; neurovascular bundle; VIBE; contrast medium; ECHO SEQUENCE; GRADIENT; NERVE; TUMORS; HEAD; NECK;
D O I
10.1259/dmfr.20170245
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the validity of plain volumetric interpolated breath-hold examinations (VIBEs) for detecting the course of the mandibular canal, and to compare the results with contrast-enhanced (CE) VIBE images. Methods: From our imaging archives, we collected 28 cases taken with a VIBE sequence both before and after intravenous administration of gadolinium hydrate, and then two observers evaluated neurovascular bundle (NVB) visibility in the VIBE images. For the invisible NVB cases, we identified the invisible areas and analysed the causes of invisibility. For cases that also had corresponding CT thin slice images, we obtained a fusion image between MRI and CT, and investigated the relationship between the NVB in VIBE and the mandibular canal in CT images. Results: The visibility of the NVBs in plain VIBE was 89%, the same as on CE VIBE. There were three invisible cases in each plain and CE VIBE images. The invisible areas were premolar in three cases, and molar in one case, and the causes of the invisibility were a metallic artefact in one case and motion artefacts in the other two cases. Conclusions: A plain VIBE can depict the NVB at the same rate as CE VIBE, and is suitable for detecting NVBs.
引用
收藏
页数:5
相关论文
共 34 条
  • [31] Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
    Miura, Hideharu
    Ozawa, Shuichi
    Doi, Yoshiko
    Nakao, Minoru
    Kubo, Katsumaro
    Kenjo, Masahiko
    Nagata, Yasushi
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (04) : 575 - 585
  • [32] Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique
    Ogawa, Masaki
    Kawai, Tatsuya
    Kan, Hirohito
    Kobayashi, Susumu
    Akagawa, Yoshihiro
    Suzuki, Kazushi
    Nojiri, Shunsuke
    Ozawa, Yoshiyuki
    Shibamoto, Yuta
    ABDOMINAL IMAGING, 2015, 40 (08): : 3091 - 3098
  • [33] Clinical feasibility of an abdominal thin-slice breath-hold single-shot fast spin echo sequence processed using a deep learning-based noise-reduction approach
    Tajima, Taku
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Akahane, Masaaki
    Yoshioka, Naoki
    Abe, Osamu
    Ohtomo, Kuni
    Kiryu, Shigeru
    MAGNETIC RESONANCE IMAGING, 2022, 90 : 76 - 83
  • [34] Breath-hold High-resolution T1-weighted Gradient Echo Liver MR Imaging with Compressed Sensing Obtained during the Gadoxetic Acid-enhanced Hepatobiliary Phase: Image Quality and Lesion Visibility Compared with a Standard T1-weighted Sequence
    Ihara, Kenichiro
    Onoda, Hideko
    Tanabe, Masahiro
    Iida, Etsushi
    Ueda, Takaaki
    Kobayashi, Taiga
    Higashi, Mayumi
    Nickel, Marcel Dominik
    Imai, Hiroshi
    Ito, Katsuyoshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (02) : 146 - 152