Magnetic properties of pseudotachylytes from western Jamtland, central Swedish Caledonides

被引:4
作者
Almqvist, Bjarne S. G. [1 ]
Bender, Hagen [2 ]
Bergman, Amanda [2 ,3 ]
Ring, Uwe [2 ]
机构
[1] Dept Earth Sci, Geophys, Villavagen 16, S-75236 Uppsala, Sweden
[2] Stockholm Univ, Dept Geol Sci, S-10691 Stockholm, Sweden
[3] Ramboll Sverige AB, Box 17009,Krukmakargatan 21, S-10462 Stockholm, Sweden
关键词
FREQUENCY-DEPENDENT SUSCEPTIBILITY; OROGENIC WEDGE; FAULT; ANISOTROPY; MECHANISM; EXTENSION; SLIP;
D O I
10.5194/se-11-807-2020
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Fault kinematics can provide information on the relationship and assembly of tectonic units in an orogen. Magnetic fabric studies of faults where pseudotachylytes form have recently been used to determine direction and sense of seismic slip in prehistoric earthquakes. Here we apply this methodology to study magnetic fabrics of pseudotachylytes in field structures of the Koli Nappe Complex (central Swedish Caledonides), with the aim to determine fault kinematics and decipher the role of seismic faulting in the assembly of the Caledonian nappe pile. Because the pseudotachylyte veins are thin, we focused on small (ca. 0.2 to 0.03 cm(3)) samples for measuring the anisotropy of magnetic susceptibility. The small sample size challenges conventional use of magnetic anisotropy and results acquired from such small specimens demand cautious interpretation. Importantly, we find that magnetic fabric results show inverse proportionality among specimen size, degree of magnetic anisotropy and mean magnetic susceptibility, which is most likely an analytical artifact related to instrument sensitivity and small sample dimensions. In general, however, it is shown that the principal axes of magnetic susceptibility correspond to the orientation of foliation and lineation, where the maximum susceptibility (k(1)) is parallel to the mineral lineation, and the minimum susceptibility (k(3)) is dominantly oriented normal to schistosity. Furthermore, the studied pseudotachylytes develop distinct magnetic properties. Pristine pseudotachylytes preserve a signal of ferrimagnetic magnetite that likely formed during faulting. In contrast, portions of the pseudotachylytes have altered, with a tendency of magnetite to break down to form chlorite. Despite magnetite breakdown, the altered pseudotachylyte mean magnetic susceptibility is nearly twice that of altered pseudotachylyte, likely originating from the Fe-rich chlorite, as implied by temperature-dependent susceptibility measurements and thin-section observations. Analysis of structural and magnetic fabric data indicates that seismic faulting occurred during exhumation into the upper crust, but these data yield no kinematic information on the direction and sense of seismic slip. Additionally, the combined structural field and magnetic fabric data suggest that seismic faulting was postdated by brittle E-W extensional deformation along steep normal faults. Although the objective of finding kinematic indicators for the faulting was not fully achieved, we believe that the results from this study may help guide future studies of magnetic anisotropy with small specimens (< 1 cm(3)), as well as in the interpretation of magnetic properties of pseudotachylytes.
引用
收藏
页码:807 / 828
页数:22
相关论文
共 44 条
[1]  
[Anonymous], STRUCTURAL METAMORPH
[2]  
[Anonymous], 2017, INSIGHTS QUANTIFICAT
[3]   MYLONITES AND PSEUDOTACHYLITES ASSOCIATED WITH THRUSTING OF THE KOLI NAPPES, TANNFORSFALTET, CENTRAL SWEDISH CALEDONIDES [J].
BECKHOLMEN, M .
GEOLOGISKA FORENINGENS I STOCKHOLM FORHANDLINGAR, 1982, 104 :23-32
[4]   THE DEFORMATION SEQUENCE IN THE HAGGSJO-MUSVALTJARNEN RENSJONASET AREA IN WESTERN JAMTLAND, SWEDISH CALEDONIDES [J].
BECKHOLMEN, M .
GEOLOGISKA FORENINGENS I STOCKHOLM FORHANDLINGAR, 1983, 105 :119-130
[5]   Metamorphic Zonation by Out-of-Sequence Thrusting at Back-Stepping Subduction Zones: Sequential Accretion of the Caledonian Internides, Central Sweden [J].
Bender, H. ;
Ring, U. ;
Almqvist, B. S. G. ;
Grasemann, B. ;
Stephens, M. B. .
TECTONICS, 2018, 37 (10) :3545-3576
[6]   Absolute timing of Caledonian orogenic wedge assembly, Central Sweden, constrained by Rb-Sr multi-mineral isochron data [J].
Bender, Hagen ;
Glodny, Johannes ;
Ring, Uwe .
LITHOS, 2019, 344 :339-359
[7]   Accretion and lateral extension in an orogenic wedge: evidence from a segment of the Seve-Koli terrane boundary, central Scandinavian Caledonides [J].
Bergman, S ;
Sjostrom, H .
JOURNAL OF STRUCTURAL GEOLOGY, 1997, 19 (08) :1073-1091
[8]   ANISOTROPY OF MAGNETIC-SUSCEPTIBILITY - ROCK COMPOSITION VERSUS STRAIN [J].
BORRADAILE, G .
TECTONOPHYSICS, 1987, 138 (2-4) :327-329
[9]   Tectonic applications of magnetic susceptibility and its anisotropy [J].
Borradaile, GJ ;
Henry, B .
EARTH-SCIENCE REVIEWS, 1997, 42 (1-2) :49-93
[10]   Structural geology, petrofabrics and magnetic fabrics (AMS, AARM, AIRM) [J].
Borradaile, Graham J. ;
Jackson, Mike .
JOURNAL OF STRUCTURAL GEOLOGY, 2010, 32 (10) :1519-1551