Comparative Evaluation of Real-Time PCR Methods for Human Noroviruses in Wastewater and Human Stool

被引:10
作者
Masago, Yoshifumi [1 ,3 ]
Konta, Yoshimitsu [1 ]
Kazama, Shinobu [1 ]
Inaba, Manami [1 ]
Imagawa, Toshifumi [2 ,4 ]
Tohma, Kentaro [2 ]
Saito, Mayuko [2 ]
Suzuki, Akira [2 ,5 ]
Oshitani, Hitoshi [2 ]
Omura, Tatsuo [1 ]
机构
[1] Tohoku Univ, New Ind Creat Hatchery Ctr, Sendai, Miyagi, Japan
[2] Tohoku Univ, Grad Sch Med, Sendai, Miyagi, Japan
[3] United Nations Univ, Inst Adv Study Sustainabil, Shibuya Ku, Tokyo, Japan
[4] Natl Inst Infect Dis, Dept Virol 2, Tokyo, Japan
[5] Tohoku Univ, Dept Pediat, Grad Sch Med, Sendai, Miyagi, Japan
来源
PLOS ONE | 2016年 / 11卷 / 08期
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
REVERSE-TRANSCRIPTION-PCR; ENVIRONMENTAL SURVEILLANCE; UNITED-STATES; GENOGROUP-I; RT-PCR; VIRUSES; ASSAYS;
D O I
10.1371/journal.pone.0160825
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Selecting the best quantitative PCR assay is essential to detect human norovirus genome effectively from clinical and environmental samples because no cell lines have been developed to propagate this virus. The real-time PCR methods for noroviruses GI (4 assays) and GII (3 assays) were evaluated using wastewater (n = 70) and norovirus-positive stool (n = 77) samples collected in Japan between 2012 and 2013. Standard quantitative PCR assays recommended by the U.S. Environmental Protection Agency, International Organization for Standardization, and Ministry of Health, Labour and Welfare, Japan, together with recently reported assays were included. Significant differences in positive rates and quantification cycles were observed by non-parametric analysis. The present study identifies the best assay for norovirus GI and GII to amplify norovirus genomes efficiently.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Guidelines for validation of qualitative real-time PCR methods
    Broeders, S.
    Huber, I.
    Grohmann, L.
    Berben, G.
    Taverniers, I.
    Mazzara, M.
    Roosens, N.
    Morisset, D.
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2014, 37 (02) : 115 - 126
  • [22] Utility of Real-Time Taqman PCR for Antemortem and Postmortem Diagnosis of Human Rabies
    Mani, Reeta Subramaniam
    Madhusudana, Shampur Narayan
    Mahadevan, Anita
    Reddy, Vijayalakshmi
    Belludi, Ashwin Yajaman
    Shankar, Susarla Krishna
    JOURNAL OF MEDICAL VIROLOGY, 2014, 86 (10) : 1804 - 1812
  • [23] Quantification of human astroviruses in sewage using real-time RT-PCR
    Le Cann, P
    Ranarijaona, S
    Monpoeho, S
    Le Guyader, F
    Ferré, V
    RESEARCH IN MICROBIOLOGY, 2004, 155 (01) : 11 - 15
  • [24] Real-Time PCR
    Jia, Yibing
    LABORATORY METHODS IN CELL BIOLOGY: BIOCHEMISTRY AND CELL CULTURE, 2012, 112 : 55 - 68
  • [25] Doubling Throughput of a Real-Time PCR
    Ahrberg, Christian D.
    Neuzil, Pavel
    SCIENTIFIC REPORTS, 2015, 5
  • [26] Environmental Detection of Genogroup I, II, and IV Noroviruses by Using a Generic Real-Time Reverse Transcription-PCR Assay
    Miura, Takayuki
    Parnaudeau, Sylvain
    Grodzki, Marco
    Okabe, Satoshi
    Atmar, Robert L.
    Le Guyader, Francoise S.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2013, 79 (21) : 6585 - 6592
  • [27] Data Acceptance Criteria for Standardized Human-Associated Fecal Source Identification Quantitative Real-Time PCR Methods
    Shanks, Orin C.
    Kelty, Catherine A.
    Oshiro, Robin
    Haugland, Richard A.
    Madi, Tania
    Brooks, Lauren
    Field, Katharine G.
    Sivaganesan, Mano
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2016, 82 (09) : 2773 - 2782
  • [28] Quantification of Chlamydia pneumoniae in cultured human macrophages and HL cells: comparison of real-time PCR, immunofluorescence and ELISA methods
    Poikonen, Kari
    Lajunen, Taina
    Silvennoinen-Kassinen, Sylvi
    Leinonen, Maija
    Saikku, Pekka
    APMIS, 2010, 118 (01) : 45 - 48
  • [29] Detection of human bocavirus and human metapneumovirus by real-time PCR from patients with respiratory symptoms in Southern Brazil
    Pilger, Diogo Andre
    Cantarelli, Vlademir Vicente
    Amantea, Sergio Luis
    Leistner-Segal, Sandra
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2011, 106 (01): : 56 - 60
  • [30] Comparative analytical evaluation of the respiratory TaqMan Array Card with real-time PCR and commercial multi-pathogen assays
    Harvey, John J.
    Chester, Stephanie
    Burke, Stephen A.
    Ansbro, Marisela
    Aden, Tricia
    Gose, Remedios
    Sciulli, Rebecca
    Bai, Jing
    DesJardin, Lucy
    Benfer, Jeffrey L.
    Hall, Joshua
    Smole, Sandra
    Doan, Kimberly
    Popowich, Michael D.
    St George, Kirsten
    Quinlan, Tammy
    Halse, Tanya A.
    Li, Zhen
    Perez-Osorio, Ailyn C.
    Glover, William A.
    Russell, Denny
    Reisdorf, Erik
    Whyte, Thomas, Jr.
    Whitaker, Brett
    Hatcher, Cynthia
    Srinivasan, Velusamy
    Tatti, Kathleen
    Tondella, Maria Lucia
    Wang, Xin
    Winchell, Jonas M.
    Mayer, Leonard W.
    Jernigan, Daniel
    Mawle, Alison C.
    JOURNAL OF VIROLOGICAL METHODS, 2016, 228 : 151 - 157