Tear Interferometric Patterns Reflect Clinical Tear Dynamics in Dry Eye Patients

被引:64
作者
Arita, Reiko [1 ,2 ]
Morishige, Naoyuki [2 ,3 ]
Fujii, Tatsuya [2 ,4 ]
Fukuoka, Shima [2 ,5 ]
Chung, Jae Lim [6 ]
Seo, Kyoung Yul [7 ]
Itoh, Kouzo [1 ]
机构
[1] Itoh Clin, Saitama, Japan
[2] Lid & Meibomian Gland Working Grp, Saitama, Japan
[3] Yamaguchi Univ, Grad Sch Med, Dept Ophthalmol, Ube, Yamaguchi, Japan
[4] Kowa Pharmaceut Co Ltd, Nagoya, Aichi, Japan
[5] Omiya Hamada Eye Clin, Saitama, Japan
[6] Konyang Univ Coll Med, Kims Eye Hosp, Seoul, South Korea
[7] Yonsei Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
基金
日本学术振兴会;
关键词
tear interferometry; dry eye; meibomiangland; FILM LIPID-LAYER; MEIBOMIAN GLAND DYSFUNCTION; INTERFERENCE IMAGES; KINETIC-ANALYSIS; THICKNESS; EVAPORATION; BREAKUP; SURFACE;
D O I
10.1167/iovs.16-19788
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We investigated whether the tear interferometric pattern was able to identify differences in tear film kinetics among clinical subtypes of dry eye. METHODS. A total of 138 eyes of 76 subjects (38 men and 38 women; mean age +/- SD, 61.6 +/- 16.2 years) with or without dry eye who visited Itoh Clinic from May to August 2015 were enrolled in a cross-sectional study. Clinical diagnosis of dry eye subtype was based on tear film parameters. The pattern of tear film kinetics determined by interferometry was classified as 0 (monotonous gray or multicolor interferometric fringe with a noninvasive breakup time [NIBUT] of >= 5 seconds), 1 (multicolor interferometric fringe with a NIBUT of <5 seconds), or 2 (grayish amorphous interferometric fringe with a NIBUT of <5 seconds), and reliability of classification was evaluated. Lipid layer thickness (LLT) for the tear film was also determined by interferometry. RESULTS. Interrater kappa values for evaluation of interferometric patterns ranged from 0.57 to 0.94 for both physicians and nonphysicians with reference to a dry eye expert, the latter of whom showed an intrarater reliability of 0.90. The distribution of eyes among interferometric patterns 0, 1, and 2 coincided well with the clinical subgroups of normal tear condition, non-Sjogren syndrome aqueous-deficient dry eye, and meibomian gland dysfunction, respectively. A multicolor interferometric fringe was essentially observed only at an LLT of >70 nm. CONCLUSIONS. Tear interferometry was able to reliably distinguish clinical subtypes of dry eye by reflecting the balance between the lipid and aqueous layers of the tear film.
引用
收藏
页码:3928 / 3934
页数:7
相关论文
共 40 条
[1]  
Amano S, 2010, J EYE ATARASHII GANK, V27, P627
[2]  
[Anonymous], EYE CONTACT LENS
[3]   Noncontact infrared meibography to document age-related changes of the meibomian glands in a normal population [J].
Arita, Reiko ;
Itoh, Kouzo ;
Inoue, Kenji ;
Amano, Shiro .
OPHTHALMOLOGY, 2008, 115 (05) :911-915
[4]   Increased Tear Fluid Production as a Compensatory Response to Meibomian Gland Loss A Multicenter Cross-sectional Study [J].
Arita, Reiko ;
Morishige, Naoyuki ;
Koh, Shizuka ;
Shirakawa, Rika ;
Kawashima, Motoko ;
Sakimoto, Tohru ;
Suzuki, Takashi ;
Tsubota, Kazuo .
OPHTHALMOLOGY, 2015, 122 (05) :925-933
[5]   Proposed Diagnostic Criteria for Obstructive Meibomian Gland Dysfunction [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Syuji ;
Maeda, Koshi ;
Furuta, Ayumu ;
Fukuoka, Shima ;
Tomidokoro, Atsuo ;
Amano, Shiro .
OPHTHALMOLOGY, 2009, 116 (11) :2058-2063
[6]  
Danjo Y, 1995, ACTA OPHTHALMOL SCAN, V73, P501
[7]   AN INSTRUMENT FOR INVIVO TEAR FILM INTERFEROMETRY [J].
DOANE, MG .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (06) :383-388
[8]   More to Stable Tears Than Thickness of the Tear Film Lipid Layer [J].
Fenner, Beau J. ;
Tong, Louis .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) :1601-1601
[9]   Evaluation of Lipid Layer Thickness Measurement of the Tear Film as a Diagnostic Tool for Meibomian Gland Dysfunction [J].
Finis, David ;
Pischel, Nadja ;
Schrader, Stefan ;
Geerling, Gerd .
CORNEA, 2013, 32 (12) :1549-1553
[10]   Computer-synthesis of an interference color chart of human tear lipid layer, by a colorimetric approach [J].
Goto, E ;
Dogru, M ;
Kojima, T ;
Tsubota, K .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) :4693-4697