Corrosion behavior of coupled active and passive reinforcing steels in simulated concrete pore solution

被引:28
作者
Dong, Zheng [1 ,2 ]
Poursaee, Amir [2 ,3 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Struct Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Clemson Univ, Glenn Dept Civil Engn, Clemson, SC 29634 USA
[3] Clemson Univ, Dept Civil Engn, Dept Mat Sci & Engn, Clemson, SC 29634 USA
关键词
Corrosion; Reinforcing steel; Concrete; Pore solution; Galvanic corrosion; Coupling; INDUCED MACROCELL CORROSION; CHLORIDE-INDUCED CORROSION; RATE-LIMITING STEP; PATCH REPAIRS; MICROCELL; MORTAR; CURRENTS; REINFORCEMENTS; PERFORMANCE; PORTLAND;
D O I
10.1016/j.conbuildmat.2019.117955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study aimed to investigate the corrosion behavior of coupled active and passive steels in concrete simulated environment. Three different active-to-passive area (A/P) ratios (i.e. A/P = 1/1, 1/3, 1/20) were studied by changing the exposed area of the active steel while keeping the passive steel constant. For each group of A/P ratio, three cells were prepared: individual cell with active steel specimens, individual cell with passive steel specimens, and a coupled cell which connected active and passive steels. All specimens were immersed in a simulated concrete pore solution for 14 days. Afterwards, 3 wt% NaCl was added to the cells. Different electrochemical measurement techniques were used to assess the influence of galvanic coupling and A/P ratio on the corrosion behavior of the steel specimens. Results indicated that coupling changed the corrosion behavior of the active steel. In the case of A/P = 1/1, the corrosion was mostly observed in the form of localized corrosion, whereas in the case of A/P = 1/20, a more general and severe corrosion was observed. In addition, coupling increased the anodic and cathodic Tafel slopes which are closely related to the iron oxidation rate (i.e. corrosion rate). (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Corrosion Assessment of Coupled Steel Reinforcement with Ni-Ti-Based Shape Memory Alloy in Simulated-Concrete Pore Solution
    Alarab, L. Abo
    Ross, B. E.
    Poursaee, A.
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2016, 28 (08)
  • [2] Galvanic currents and corrosion rates of reinforcements measured in cells simulating different pitting areas caused by chloride attack in sodium hydroxide
    Andrade, C.
    Garces, P.
    Martinez, I.
    [J]. CORROSION SCIENCE, 2008, 50 (10) : 2959 - 2964
  • [3] THE EFFECT OF MACROCELLS BETWEEN ACTIVE AND PASSIVE AREAS OF STEEL REINFORCEMENTS
    ANDRADE, C
    MARIBONA, IR
    FELIU, S
    GONZALEZ, JA
    FELIU, S
    [J]. CORROSION SCIENCE, 1992, 33 (02) : 237 - 249
  • [4] Chloride induced reinforcement corrosion: Rate limiting step of early pitting corrosion
    Angst, Ueli
    Elsener, Bernhard
    Larsen, Claus K.
    Vennesland, Oystein
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (17) : 5877 - 5889
  • [5] INFLUENCE OF CATHODE-TO-ANODE AREA RATIO AND SEPARATION DISTANCE ON GALVANIC CORROSION CURRENTS OF STEEL IN CONCRETE CONTAINING CHLORIDES
    ARYA, C
    VASSIE, PRW
    [J]. CEMENT AND CONCRETE RESEARCH, 1995, 25 (05) : 989 - 998
  • [6] 3D simulation of localized steel corrosion in chloride contaminated reinforced concrete
    Cao, Chong
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 72 : 434 - 443
  • [7] Modelling of interaction between corrosion-induced concrete cover crack and steel corrosion rate
    Cao, Chong
    Cheung, Moe M. S.
    Chan, Ben Y. B.
    [J]. CORROSION SCIENCE, 2013, 69 : 97 - 109
  • [8] Microcell versus galvanic corrosion currents in carbonated concrete
    Castel, Arnaud
    Nasser, Abdelkader
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2014, 66 (14) : 697 - 707
  • [9] The beneficial galvanic effect of the constituent phases in 2205 duplex stainless steel on the passive films formed in a 3.5% NaCl solution
    Cheng, Xuequn
    Wang, Yi
    Dong, Chaofang
    Li, Xiaogang
    [J]. CORROSION SCIENCE, 2018, 134 : 122 - 130
  • [10] Dong Z., 2018, Sixth International Conference on the Durability of Concrete Structures, V502, P2