A New Method for Offline Compensation of Phase Discrepancy in Measuring the Core Loss With Rectangular Voltage

被引:7
作者
Rasekh, Navid [1 ]
Wang, Jun [1 ]
Yuan, Xibo [1 ]
机构
[1] Univ Bristol, Dept Elect & Elect Engn, Bristol BS8 1UB, Avon, England
来源
IEEE OPEN JOURNAL OF THE INDUSTRIAL ELECTRONICS SOCIETY | 2021年 / 2卷
关键词
Loss measurement; Core loss; Current measurement; Windings; Voltage measurement; Phase measurement; Magnetic cores; B-H loop measurement; core loss; phase discrepancy error; magnetic losses; two-winding method; WAVE-FORMS; TRANSFORMER;
D O I
10.1109/OJIES.2021.3076137
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays accurate characterization of the magnetic component losses becomes increasingly important in the design stage of power converters. As the main challenge in characterizing a magnetic component, the core loss is commonly measured through the two winding B-H loop measurement method that is susceptible to the phase discrepancy error, especially for low-permeability, low-loss cores. This paper, therefore, proposes a new offline method to compensate the phase discrepancy error in high-frequency core loss measurement under rectangular voltage excitation. In the post-processing of measured waveforms, the phase discrepancy is compensated by shifting the measured current horizontally to align with a reference phase angle, which is found from an offline impedance sweep on the component-under-test and FFT analysis. As a result, the testing voltage and current waveforms can be measured without considering deskew at the time of measuring. Additionally, this method is more accurate than calibration methods considering a fixed frequency response (e.g., a deskew fixture), because it considers the frequency response across the whole spectrum. The proposed approach can be well applied for typical PWM converters with switching frequencies up to hundreds of kilohertz, for which the effective voltage harmonics extend to a few megahertz range that can be well evaluated with an impedance analyzer. The presented method is experimentally verified against the existing partial cancellation method which is immune to phase discrepancy error.
引用
收藏
页码:302 / 314
页数:13
相关论文
共 36 条
[1]   The effect of DC bias conditions on Ferrite core losses [J].
Baguley, C. A. ;
Carsten, B. ;
Madawala, U. K. .
IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (02) :246-252
[2]  
Chioye L., 2013, CHOOSE RIGHT FFT WIN
[3]  
Foo BX, 2017, APPL POWER ELECT CO, P861, DOI 10.1109/APEC.2017.7930797
[4]   Evaluation of Magnetic Materials for Very High Frequency Power Applications [J].
Han, Yehui ;
Cheung, Grace ;
Li, An ;
Sullivan, Charles R. ;
Perreault, David J. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (01) :425-435
[5]   A practical transformer core loss measurement scheme for high-frequency power converter [J].
Han, Yongtao ;
Liu, Yan-Fei .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (02) :941-948
[6]   A practical copper loss measurement method for the planar transformer in high-frequency switching converters [J].
Han, Yongtao ;
Eberle, Wilson ;
Liu, Yan-Fei .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (04) :2276-2287
[7]  
Herbert E., 2012, TESTING CORE LOSS RE
[8]   New High-Frequency Core Loss Measurement Method With Partial Cancellation Concept [J].
Hou, Dongbin ;
Mu, Mingkai ;
Lee, Fred C. ;
Li, Qiang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (04) :2987-2994
[9]  
Javidi NF, 2017, APPL POWER ELECT CO, P876, DOI 10.1109/APEC.2017.7930799
[10]  
Javidi NF, 2016, 2016 IEEE 2ND ANNUAL SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC)