Dynamic analysis of office lighting smart controls management based on user requirements

被引:13
作者
Angel Campano, Miguel [1 ]
Acosta, Ignacio [1 ]
Dominguez, Samuel [1 ]
Lopez-Lovillo, Remedios [1 ]
机构
[1] Univ Seville, Inst Univ Arquitectura & Ciencias Construcc, Seville 41012, Spain
关键词
Continuous daylight autonomy; Overcast daylight autonomy; User requirement; Energy saving; Smart control; ENERGY SAVINGS; CONTROL-SYSTEMS; DAYLIGHT; PERFORMANCE; DESIGN; CONSUMPTION; BUILDINGS; OCCUPANCY; EFFICIENCY; ACCURACY;
D O I
10.1016/j.autcon.2021.104021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Daylight dynamic metrics provide an alternative approach for the assessment of the energy savings promoted by lighting control systems. This research aims to quantify the energy savings allowed by lighting smart controls using continuous and overcast daylight autonomy, novel metrics tested monitoring a mesh of illuminance-meters in test cells over a one-year period. Three types of smart controls are proposed, based on switches and dimmers, some of which were managed by illuminance-meters and irradiance detectors. Energy savings are assessed according to weather data, room dimensions, inner reflectances, window size and user requirements-illuminance needs and working hours. The results show a reduction in the average energy consumption of electric lighting of up to 23%, suggesting the suitability of the smart controls proposed. Smart controls without illuminance-meter feedback are only recommended for shallow rooms with low requirements, while dark deep rooms demand a complex dimming system managed by external illuminance-meters.
引用
收藏
页数:17
相关论文
共 65 条
[31]   An analysis of electricity end-use in air-conditioned office buildings in Hong Kong [J].
Lam, JC ;
Li, DHW ;
Cheung, SO .
BUILDING AND ENVIRONMENT, 2003, 38 (03) :493-498
[32]   Estimation methodology for the electricity consumption with daylight- and occupancy-controlled artificial lighting [J].
Larsen, Olena Kalyanova ;
Jensen, Rasmus Lund ;
Antonsen, Therese ;
Stromberg, Ida .
CISBAT 2017 INTERNATIONAL CONFERENCE FUTURE BUILDINGS & DISTRICTS - ENERGY EFFICIENCY FROM NANO TO URBAN SCALE, 2017, 122 :733-738
[33]  
LBNL, 2012, 1278 LBNL
[34]   Comparison of sensorless dimming control based on building modeling and solar power generation [J].
Lee, Naeun ;
Kim, Jonghun ;
Jang, Cheolyong ;
Sung, Yoondong ;
Jeong, Hakgeun .
ENERGY, 2015, 81 :15-20
[35]   Study of daylight data and lighting energy savings for atrium corridors with lighting dimming controls [J].
Li, Danny H. W. ;
Cheung, Angela C. K. ;
Chow, Stanley K. H. ;
Lee, Eric W. M. .
ENERGY AND BUILDINGS, 2014, 72 :457-464
[36]  
Lo Verso V.R.M., 2019, J. Daylighting, V6, P131, DOI 10.15627/jd.2019.1
[37]  
Lopez R. M., 2019, International Journal of Engineering and Technology, V11, P143, DOI 10.7763/IJET.2019.V11.1137
[38]   Energy saving claims for lighting controls in commercial buildings [J].
Lowry, Gordon .
ENERGY AND BUILDINGS, 2016, 133 :489-497
[39]   Design and Performance of Test Cells as an Energy Evaluation Model of Facades in a Mediterranean Building Area [J].
Luis Leon-Rodriguez, Angel ;
Suarez, Rafael ;
Bustamante, Pedro ;
Angel Campano, Miguel ;
Moreno-Rangel, David .
ENERGIES, 2017, 10 (11)
[40]  
Mardaljevic J., 1995, Lighting Research and Technology, V27, P181