Adequately FRP confined reinforced concrete columns under axial compressive monotonic or cyclic loading

被引:109
作者
Rousakis, Theodoros C. [1 ]
Karabinis, Athanasios I. [1 ]
机构
[1] DUTh, Dept Civil Engn, Lab Reinforced Concrete, Xanthi 67100, Greece
关键词
Concrete; Steel; Composites; Fibre-reinforced polymers; Confinement; Strengthening; Columns; Cyclic load; Unloading; Axial; STRESS-STRAIN MODEL; JACKETED CONCRETE; BEHAVIOR; STRENGTH; MEMBERS; FAILURE; SIZE;
D O I
10.1617/s11527-011-9810-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study presents the experimental behavior of reinforced concrete square section specimens, externally confined by carbon or glass Fiber Reinforced Polymer (FRP) sheets. The columns are subjected to axial compressive monotonic or repeated load-unload cycles gradually increasing up to failure. The research focuses on columns with longitudinal bars which are critical to premature buckling while examining their effect on lower limit cases of strengthening through FRP confinement. Experiments include also plain concrete FRP confined columns and columns with bars adequately supported by transverse steel reinforcement for comparison. External FRP strengthening covers a wide range of volumetric mechanical FRP confinement ratios allowing comparative investigations. A significant variation in the behavior of FRP confined concrete comes up when bars are unstable, for a light external strengthening scheme as well as for monotonic or cyclic loading. The lower limits proposed by existing recommendations for adequate FRP confinement strengthening of columns are examined.
引用
收藏
页码:957 / 975
页数:19
相关论文
共 48 条
[1]  
*ACI COMM, 2008, 4402R08 ACI COMM
[2]  
[Anonymous], 2004, 19981 EN
[3]  
[Anonymous], 2004, 2002004 CNRDT NAT RE
[4]   Strength and strain capacities of concrete compression members reinforced with FRP [J].
Campione, G ;
Miraglia, N .
CEMENT & CONCRETE COMPOSITES, 2003, 25 (01) :31-41
[5]  
CAREY S, 2005, ACI STRUCT J JUL, P596
[6]  
Comite Eurointernational du Beton, 1993, CEB FIP MOD COD 90
[7]  
Fam AZ, 2001, ACI STRUCT J, V98, P451
[8]  
*FED INT BET, 2003, FIB B, V24
[9]   Axial stress-strain relationship for FRP confined circular and rectangular concrete columns [J].
Harajli, Mohamed H. .
CEMENT & CONCRETE COMPOSITES, 2006, 28 (10) :938-948
[10]  
Harajli MH, 2006, ACI STRUCT J, V103, P672