3D MRI provides improved visualization and detection of aortic arch plaques compared to transesophageal echocardiography

被引:19
作者
Harloff, Andreas [1 ]
Brendecke, Stefanie Marie [1 ]
Simon, Jan [1 ]
Assefa, Dawit [2 ]
Wallis, Wolf [1 ]
Helbing, Thomas [2 ]
Weber, Johannes [3 ]
Frydrychowicz, Alex [4 ]
Vach, Werner [5 ]
Weiller, Cornelius [1 ]
Markl, Michael [6 ]
机构
[1] Univ Hosp Freiburg, Dept Neurol, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Cardiol & Angiol, D-79106 Freiburg, Germany
[3] Univ Hosp Freiburg, Dept Neuroradiol, D-79106 Freiburg, Germany
[4] Univ Hosp Schleswig Holstein, Clin Radiol & Nucl Med, Lubeck, Germany
[5] Univ Freiburg, Inst Med Biometry & Med Informat, D-79106 Freiburg, Germany
[6] Northwestern Univ, Dept Radiol & Biomed Engn, Chicago, IL 60611 USA
关键词
aorta; transesophageal echocardiography; stroke; atherosclerosis; INTIMA-MEDIA THICKNESS; ATHEROSCLEROTIC DISEASE; STROKE; RISK; RELIABILITY;
D O I
10.1002/jmri.23679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare 3D magnetic resonance imaging (3D MRI) with transesophageal echocardiography (TEE) for the detection of complex aortic plaques (=4 mm thick, ulcerated, or containing mobile thrombi). Materials and Methods: In all, 99 consecutive patients with acute cryptogenic stroke and =3 mm thick aortic plaques in TEE were prospectively included. 3D MRI comprised T1-weighted bright blood MRI with complete aortic coverage (spatial resolution 1 mm3). Wall thickness and occurrence of complex plaques in ascending aorta (AAo), aortic arch (AA), and descending aorta (DAo) and image quality for each segment was rated for MRI and TEE. Results: MRI detected more complex plaques than TEE (MRI vs. TEE): AAo 13 vs. 7; AA 37 vs. 11; differences were smaller in the DAo: 101 vs. 70. Image quality was higher for MRI in AAo and AA (P < 0.001) and superior for TEE in DAo (P < 0.001). MRI revealed additional complex plaques in the proximal aorta in 19 of 58 patients (32.8%) categorized as cryptogenic after complete routine diagnostics including TEE. Conclusion: Due to improved visualization of the aorta 3D MRI allows to detect more complex plaques than TEE. This renders 3D MRI particularly valuable for patients with cryptogenic stroke and for trials evaluating optimal treatment in aortic atherosclerosis. J. Magn. Reson. Imaging 2012;36:604611. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 23 条
[1]   CLASSIFICATION OF SUBTYPE OF ACUTE ISCHEMIC STROKE - DEFINITIONS FOR USE IN A MULTICENTER CLINICAL-TRIAL [J].
ADAMS, HP ;
BENDIXEN, BH ;
KAPPELLE, LJ ;
BILLER, J ;
LOVE, BB ;
GORDON, DL ;
MARSH, EE ;
KASE, CS ;
WOLF, PA ;
BABIKIAN, VL ;
LICATAGEHR, EE ;
ALLEN, N ;
BRASS, LM ;
FAYAD, PB ;
PAVALKIS, FJ ;
WEINBERGER, JM ;
TUHRIM, S ;
RUDOLPH, SH ;
HOROWITZ, DR ;
BITTON, A ;
MOHR, JP ;
SACCO, RL ;
CLAVIJO, M ;
ROSENBAUM, DM ;
SPARR, SA ;
KATZ, P ;
KLONOWSKI, E ;
CULEBRAS, A ;
CAREY, G ;
MARTIR, NI ;
FICARRA, C ;
HOGAN, EL ;
CARTER, T ;
GURECKI, P ;
MUNTZ, BK ;
RAMIREZLASSEPAS, M ;
TULLOCH, JW ;
QUINONES, MR ;
MENDEZ, M ;
ZHANG, SM ;
ALA, T ;
JOHNSTON, KC ;
ANDERSON, DC ;
TARREL, RM ;
NANCE, MA ;
BUDLIE, SR ;
DIERICH, M ;
HELGASON, CM ;
HIER, DB ;
SHAPIRO, RA .
STROKE, 1993, 24 (01) :35-41
[2]   ATHEROSCLEROTIC DISEASE OF THE AORTIC-ARCH AND THE RISK OF ISCHEMIC STROKE [J].
AMARENCO, P ;
COHEN, A ;
TZOURIO, C ;
BERTRAND, B ;
HOMMEL, M ;
BESSON, G ;
CHAUVEL, C ;
TOUBOUL, PJ ;
BOUSSER, MG .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (22) :1474-1479
[3]  
Amarenco P, 1996, NEW ENGL J MED, V334, P1216
[4]   Underlying Pathology of Stroke of Unknown Cause (Cryptogenic Stroke) [J].
Amarenco, Pierre .
CEREBROVASCULAR DISEASES, 2009, 27 :97-103
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Cohen A, 1997, CIRCULATION, V96, P3838
[7]   Aortic Arch Plaques and Risk of Recurrent Stroke and Death [J].
Di Tullio, Marco R. ;
Russo, Cesare ;
Jin, Zhezhen ;
Sacco, Ralph L. ;
Mohr, J. P. ;
Homma, Shunichi .
CIRCULATION, 2009, 119 (17) :2376-2382
[8]   In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta - A comparison with transesophageal echocardiography [J].
Fayad, ZA ;
Nahar, T ;
Fallon, JT ;
Goldman, M ;
Aguinaldo, JG ;
Badimon, JJ ;
Shinnar, M ;
Chesebro, JH ;
Fuster, V .
CIRCULATION, 2000, 101 (21) :2503-2509
[9]   Reliability of aortic MRI at 3 Tesla in patients with acute cryptogenic stroke [J].
Harloff, A. ;
Dudler, P. ;
Frydrychowicz, A. ;
Strecker, C. ;
Stroh, A. L. ;
Geibel, A. ;
Weiller, C. ;
Hetzel, A. ;
Hennig, J. ;
Markl, M. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (05) :540-546
[10]   Therapeutic strategies after examination by transesophageal echocardiography in 503 patients with ischemic stroke [J].
Harloff, A ;
Handke, M ;
Reinhard, M ;
Geibel, A ;
Hetzel, A .
STROKE, 2006, 37 (03) :859-864