Thin-film based sensor for the selective detection of mercury (Hg2+) ions at the picomolar range

被引:5
|
作者
Rotake, Dinesh Ramkrushna [1 ]
Darji, Anand [1 ]
Singh, Jitendra [2 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Elect Engn, Surat, India
[2] Cent Elect Engn Res Inst CSIR, Dept Smart Sensor Area, Pilani, Rajasthan, India
关键词
Nanotechnology; Biosensors; Sensors; Nanosensors; Environmental sensors; Thin film devices; Limit of detection (LOD); SAM (Self Assembled Monolayer's); Nanoparticle (NPs); Heavy Metal Ions (HMIs); SELF-ASSEMBLED MONOLAYERS; COLORIMETRIC DETECTION; SILVER NANOPARTICLES; GOLD; MN2+; CU2+; SENSITIVITY; COPPER(II); PROBE; WATER;
D O I
10.1108/SR-12-2019-0313
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Purpose The purpose of this paper is a new thin-film based sensor proposed for sensitive and selective detection of mercury (Hg2+) ions in water. The thin-film platform is easy to use and quick for heavy metal ions (HMIs) detection in the picomolar range. Ion-selective self-assembled monolayer's (SAM) of thiol used for the detection of HMIs above the Au/Ti top surface. Design/methodology/approach A thin-film based platform is suitable for the on-field experiments and testing of water samples. HMIs (antigen) and thiol-based SAM (antibody) interaction results change in surface morphology and topography. In this study, the authors have used different characterization techniques to check the selectivity of the proposed method. This change in the morphology and topography of thin-film sensor checked with Fourier-transform infrared spectroscopy, surface-enhanced Raman scattering spectroscopy, atomic force microscopy and scanning electron microscopy with energy dispersive x-ray analysis used for high-resolution images. Findings This thin-film based platform is straightforward to use and suitable for real-time detection of HMIs at the picomolar range. This thin-film based sensor platform capable of achieving a lower limit of detection (LOD) 27.42 ng/mL (136.56 pM) using SAM of Homocysteine-Pyridinedicarboxylic acid to detect Hg(2+)ions. Research limitations/implications A thin-film based technology is perfect for real-time testing and removal of HMIs, but the LOD is higher as compared to microcantilever-based devices. Originality/value The excessive use and commercialization of nanoparticle (NPs) are quickly expanding their toxic impact on health and the environment. The proposed method used the combination of thin-film and NPs, to overcome the limitation of NPs-based technique and have picomolar (136.56 pM) range of HMIs detection. The proposed thin-film-based sensor shows excellent repeatability and the method is highly reliable for toxic Hg(2+)ions detection. The main advantage of the proposed thin-film sensor is its ability to selectively remove the Hg(2+)ions from water samples just like a filter and a sensor for detection at picomolar range makes this method best among the other current-state of the art techniques.
引用
收藏
页码:485 / 495
页数:11
相关论文
共 50 条
  • [1] Highly selective piezoresistive sensor for mercury (Hg2+) ions detection using mercaptosuccinic acid-functionalized microcantilevers with cross-linked pyridinedicarboxylic acid
    Rotake, Dinesh Ramkrushna
    Darji, Anand
    Kale, Nitin S.
    SENSOR REVIEW, 2020, 40 (05) : 543 - 558
  • [2] Catalytic gold nanostars for SERS-based detection of mercury ions (Hg2+) with inverse sensitivity
    Logan, Natasha
    Lou-Franco, Javier
    Elliott, Christopher
    Cao, Cuong
    ENVIRONMENTAL SCIENCE-NANO, 2021, 8 (09) : 2718 - 2730
  • [3] Plasmonic Nano Silver: An Efficient Colorimetric Sensor for the Selective Detection of Hg2+ Ions in Real Samples
    Abbasi, Nasir Mahmood
    Hameed, Muhammad Usman
    Nasim, Najma
    Ahmed, Farid
    Altaf, Faizah
    Shahida, Shabnam
    Fayyaz, Sana
    Sabir, Syed Mubashar
    Bocchetta, Patrizia
    COATINGS, 2022, 12 (06)
  • [4] A dual sensor selective for Hg2+ and cysteine detection
    Jung, Min
    Kim, Cheal
    Harrison, Roger G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2756 - 2763
  • [5] Calix[4]arene-based fluorescent receptor for selective turn-on detection of Hg2+ ions
    Kumar, Manoj
    Kumar, Naresh
    Bhalla, Vandana
    Kaur, Amandeep
    SUPRAMOLECULAR CHEMISTRY, 2013, 25 (01) : 28 - 33
  • [6] A highly selective chemodosimeter for the rapid detection of Hg2+ ions in aqueous media
    Rode, Ambadas B.
    Kim, Jinkwon
    Kim, Sang-Ho
    Gupta, Gajendra
    Hong, In Seok
    TETRAHEDRON LETTERS, 2012, 53 (20) : 2571 - 2574
  • [7] A highly selective pyrene based fluorescent sensor toward Hg2+ detection
    Yang, Yang
    Gou, Xiaojun
    Blecha, John
    Cao, Haishi
    TETRAHEDRON LETTERS, 2010, 51 (26) : 3422 - 3425
  • [8] Photoluminescent Nanocellulosic Film for Selective Hg2+ Ion Detection
    Sun, Jing
    Fang, Wenwen
    Liza, Afroza Akter
    Gao, Rui
    Song, Junlong
    Guo, Jiaqi
    Rojas, Orlando J.
    POLYMERS, 2024, 16 (11)
  • [9] A Selective Fluorescent Sensor for Hg2+
    Li, Lian-Qing
    Meng, Li-Ping
    JOURNAL OF FLUORESCENCE, 2014, 24 (02) : 301 - 303
  • [10] Organic thin film transistors as selective sensing platforms for Hg2+ ions and the amino acid cysteine
    Ramesh, Mohan
    Lin, Hong-Cheu
    Chu, Chih-Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 76 - 79