Reference values for echocardiographic measurements of healthy newborns

被引:10
|
作者
Guzeltas, Alper [1 ]
Eroglu, Ayse Guler [1 ]
机构
[1] Istanbul Univ, Cerrahpasa Med Fac, Dept Pediat, Div Pediat Cardiol, TR-34303 Istanbul, Turkey
关键词
Body weight; M-mode echocardiography; infant; normal values; VENTRICULAR EJECTION FRACTION; M-MODE ECHOCARDIOGRAPHY; NORMAL-CHILDREN; EARLY ADULTHOOD; NORMAL INFANTS; GROWTH; LIMITS; WALL;
D O I
10.1017/S1047951111001259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess the reference values of M-mode echocardiographic measurements in healthy newborns according to body weight. Methods: From January, 2008 to June, 2008, a total of 250 - 130 female and 120 male - term healthy newborns were included in the study. M-mode echocardiographic measurements were recorded by a paediatric cardiologist in accordance with the American Society of Echocardiography recommendations. Right ventricular anterior wall end-diastolic thickness, right ventricular end-diastolic diameter, interventricular septum end-diastolic thickness, left ventricular end-diastolic diameter, left ventricular posterior wall end-diastolic thickness, interventricular septum end-systolic thickness, left ventricular end-systolic diameter, left ventricular posterior wall end-systolic thickness, aortic root dimension, left atrium dimension, left ventricular ejection, and shortening fraction were measured. Results: The values of echocardiographic measurements revealed a good correlation with body weight. When body weight increased, the measured values also increased in parallel. The measured values were not influenced by gender. Ejection and shortening fraction parameters did not change with body weight and gender. Conclusion: In this study, normative values related to body weight for cardiac chambers and wall thickness were determined in healthy newborns. These reference values can be used to evaluate whether newborns have normal or abnormal echocardiographic measurement.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 50 条
  • [41] Doppler echocardiographic assessment of pulmonary blood flow in healthy newborns
    Gournay, V
    Cambonie, G
    Rozé, JC
    ACTA PAEDIATRICA, 1998, 87 (04) : 419 - 423
  • [42] Reference intervals and allometric scaling of two-dimensional echocardiographic measurements in 150 healthy cats
    Karsten, Schober
    Stephanie, Savino
    Vedat, Yildiz
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (11): : 1764 - 1771
  • [43] Two-dimensional and M-mode echocardiographic reference values in healthy adult Saanen goats
    Leroux, A. A.
    Moonen, M. L.
    Farnir, F.
    Sandersen, C. F.
    Deleuze, S.
    Salciccia, A.
    Amory, H.
    VETERINARY RECORD, 2012, 170 (06) : 154 - U63
  • [44] DYNAMIC SONOGRAPHIC MEASUREMENTS AT THE CARPAL TUNNEL INLET: RELIABILITY AND REFERENCE VALUES IN HEALTHY WRISTS
    Filius, Anika
    Korstanje, Jan-Wiebe H.
    Selles, Ruud W.
    Hovius, Steven E. R.
    Slijper, Harm P.
    MUSCLE & NERVE, 2013, 48 (04) : 525 - 531
  • [45] REFERENCE RANGES OF ECHOCARDIOGRAPHIC MEASUREMENTS IN THE DUTCH POPULATION
    VOOGD, PJ
    RIJSTERBORGH, H
    LUBSEN, J
    ARNTZENIUS, AC
    MONSJOU, LK
    GODIJN, EH
    EUROPEAN HEART JOURNAL, 1984, 5 (09) : 762 - 770
  • [46] Bioelectrical impedance vector (BIVA) reference values for healthy term newborns 1-2 days old
    Bueno-Hernandez, Nallely
    Briones-Garduno, Jesus Carlos
    Fonseca-Sanchez, Miguel Angel
    Melendez, Guillermo
    Escobedo, Galileo
    Esquivel-Velazquez, Marcela
    CLINICAL NUTRITION ESPEN, 2025, 66 : 421 - 428
  • [47] Reference intervals for acetylated fetal hemoglobin in healthy newborns
    Paleari, Renata
    Mutta, Irene
    Musolino, Gianluca
    Salvatoni, Alessandro
    Agosti, Massimo
    Francescato, Gaia
    Mosca, Andrea
    THALASSEMIA REPORTS, 2014, 4 (02) : 52 - 54
  • [48] New Echocardiography Reference Ranges for Aotearoa (NewERA) Study: the application of international echocardiographic reference values to linear measurements of the hearts of healthy, young Maori and Pacific adults may not detect cardiac enlargement
    Whalley, Gillian A.
    Harrington, Allanah
    Christiansen, Jonathan
    Ikenasio, Bettina
    Deo, Arun
    Gamble, Greg D.
    Crengle, Sue
    NEW ZEALAND MEDICAL JOURNAL, 2022, 135 (1558) : 19 - 34
  • [49] Reference values of haemoglobins A and F in newborns according to gestational age
    Marin Soria, J. L.
    Argudo-Ramirez, A.
    Pajares Garcia, S.
    De Aledo Castillo, J. M. Gonzalez
    Quintero, Y.
    Collado, T.
    Lopez Galera, R. M.
    CLINICA CHIMICA ACTA, 2019, 493 : S602 - S602
  • [50] Reference values for germination and emergence measurements
    Ferreira, Wanessa Resende
    Ranal, Marli A.
    Santana, Denise Garcia
    BOTANY, 2022, 100 (05) : 461 - 471