Reactant Control System for Proton Exchange Membrane Fuel Cell

被引:4
作者
Rosli, R. E. [1 ]
Sulong, A. B. [1 ,2 ]
Daud, W. R. W. [1 ,3 ]
Zulkifley, M. A. [4 ]
Rosli, M. I. [1 ,3 ]
Majlan, E. H. [1 ]
Haque, M. A. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fuel Cell Inst, Ukm Bangi 43600, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Dept Mech & Mat Engn, Ukm Bangi 43600, Selangor, Malaysia
[3] Univ Kebangsaan Malaysia, Dept Chem Engn, Ukm Bangi 43600, Selangor, Malaysia
[4] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Ukm Bangi 43600, Selangor, Malaysia
来源
PROCEEDING OF 4TH INTERNATIONAL CONFERENCE ON PROCESS ENGINEERING AND ADVANCED MATERIALS (ICPEAM 2016) | 2016年 / 148卷
关键词
PEM fuel cell; on-line; non-linear dynamics; self tuning control; flow rate control; PID Controller; DEGRADATION; STARVATION; REVERSAL;
D O I
10.1016/j.proeng.2016.06.524
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The Proton Exchange Membrane Fuel Cell (PEMFC) has been a focus in many fuel cell studies for tremendous commercialization. It generates an efficient and reliable power with a suitable system to ensure its electrochemical reaction operates well. In this paper, a reactant system is being discussed. Significant parameters such as reactant pressure, flow rate and stoichiometric ratio are the major factors for a reliable performance. A fuel cell owning a complex structure with traditional reactant requirement generally gives an unsatisfactory performance when facing dynamic loading instances. Fuel starvation usually occurs especially during transients where the reactants consumed are higher than being supplied. This in turn causes a problem to the MEA components such as platinum particles agglomeration, carbon corrosion and even cell reversal problem that lead to degeneration of fuel cell. Hence, excess stoichiometric ratio need to be supplied to prevent this issue and ensure a dynamic operation at the same time avoid the wastage issues. A development of a system identification and control strategy for reactant system is significant to ensure a reliable performance of power production and longer life span of the fuel cell. Hydrogen was controlled according to the load variation and the reactant control system compensates the loading transient variation that meets the design requirements and produces a reliable performance. The Mass Flow Controller (MFC) meter used with the current input range between 0.004 to 0.020 A and was changed for the suitable supply of fuel flow accordingly. A Zigler-Nicholes method used to tune the PID controller using a parameter of Kc = 23,385, Ti = 0.011 and Td = 0.002. An optimum consumption of hydrogen observed with an average error from the overall reaction is 0.000423 A. From the result shown, the reactant control system build is competence to fulfill the loading demand. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:615 / 620
页数:6
相关论文
共 18 条
[1]   Control and experimental characterization of a methanol reformer for a 350 W high temperature polymer electrolyte membrane fuel cell system [J].
Andreasen, Soren Juhl ;
Kaer, Soren Knudsen ;
Sahlin, Simon .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (03) :1676-1684
[2]   Nonlinear control of fuel cell hybrid power sources: Part I - Voltage control [J].
Bizon, N. .
APPLIED ENERGY, 2011, 88 (07) :2559-2573
[3]   Prevention of fuel cell starvation by model predictive control of pressure, excess ratio, and current [J].
Danzer, Michael A. ;
Wittmann, Simon J. ;
Hofer, Eberhard P. .
JOURNAL OF POWER SOURCES, 2009, 190 (01) :86-91
[4]   Real-time implementation of a sliding mode controller for air supply on a PEM fuel cell [J].
Garcia-Gabin, Winston ;
Dorado, Fernando ;
Bordons, Carlos .
JOURNAL OF PROCESS CONTROL, 2010, 20 (03) :325-336
[5]  
Govindarasu R, 2012, INT J RENEW ENERGY R, V2, P652
[6]   Durability of high temperature polymer electrolyte membrane fuel cells in daily based start/stop operation mode using reformed gas [J].
Kim, Jintae ;
Kim, Minjin ;
Lee, Bong-Gu ;
Sohn, Young-Jun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (24) :7769-7776
[7]   PEM fuel cell low flow FDI [J].
Niroumand, Amir M. ;
Merida, Walter ;
Saif, Mehrdad .
JOURNAL OF PROCESS CONTROL, 2011, 21 (04) :602-612
[8]   Feedforward fuzzy-PID control for air flow regulation of PEM fuel cell system [J].
Ou, Kai ;
Wang, Ya-Xiong ;
Li, Zhen-Zhe ;
Shen, Yun-De ;
Xuan, Dong-Ji .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (35) :11686-11695
[9]  
Rosli RE, 2012, 2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), P553, DOI 10.1109/PECon.2012.6450275
[10]   Analysis of degradation in PEMFC caused by cell reversal during air starvation [J].
Taniguchi, Akira ;
Akita, Tomoki ;
Yasuda, Kazuaki ;
Miyazaki, Yoshinori .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (09) :2323-2329