Measurement of Ocular Fundus Pulsation in Healthy Subjects Using a Novel Fourier-Domain Optical Coherence Tomography

被引:35
作者
Singh, Kanwarpal [3 ,4 ]
Dion, Carolyne [3 ,4 ]
Wajszilber, Marcelo [4 ]
Ozaki, Tsuneyuki [3 ,4 ]
Lesk, Mark R. [1 ,4 ]
Costantino, Santiago [1 ,2 ,4 ]
机构
[1] Univ Montreal, Dept Ophthalmol, Fac Med, Montreal, PQ H3T 1J4, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[3] Inst Natl Rech Sci Energie Mat & Telecommun, Quebec City, PQ, Canada
[4] Hop Maison Neuve Rosemont, Ctr Rech, Montreal, PQ H1T 2M4, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
NORMAL-TENSION GLAUCOMA; OPEN-ANGLE GLAUCOMA; BLOOD-FLOW; PULSE AMPLITUDE; INTRAOCULAR-PRESSURE; ULTRAHIGH-RESOLUTION; INPUT IMPEDANCE; HIGH-SPEED; PNEUMOPLETHYSMOGRAPHY; INTERFEROMETRY;
D O I
10.1167/iovs.11-7854
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Anomalies in the pulsatility of the eye have been associated with many types of ocular pathology. Estimation of ocular pulsatility is usually obtained by measuring the variation in the intraocular pressure using tonometry-based instruments. In this work, the authors present and demonstrate the applicability of a novel and noninvasive Fourier-domain optical coherence tomography (FD-OCT) system to measure pulsatile ocular tissue movements. METHODS. The authors simultaneously measured the longitudinal movement of the cornea and the retina driven by the cardiac cycle in 21 healthy volunteers using their custom-made FD-OCT. They calculated the corresponding fundus pulse amplitude (FPA), which is the variation in the distance between the cornea and the retina. RESULTS. It was found that in young, healthy subjects, the cornea and the retina move axially during the cardiac cycle, with almost equal amplitude but with a phase difference ranging between 1 degrees and 20 degrees. The measured FPA was found to be mostly due to the relative phase difference between corneal and retinal movements, and frequency analysis revealed the presence of the harmonics of heartbeat. The root-mean-square values for cornea, retina, and FPA movements were found to be 28 +/- 9 mu m, 29 +/- 9 mu m, and 4 +/- 2 mu m, respectively. The dominant frequency component in corneal and retinal movement was found to be the second harmonic of the heartbeat. CONCLUSIONS. The technique described here is useful for a precise description of FPA and the movement of ocular tissues. Further investigations and technical improvements will be beneficial for understanding the role of choroidal pulsation in the pathophysiology of ocular diseases. (Invest Ophthalmol Vis Sci. 2011;52:8927-8932) DOI:10.1167/iovs.11-7854
引用
收藏
页码:8927 / 8932
页数:6
相关论文
共 46 条
[1]   Dominant frequency content of ocular microtremor from normal subjects [J].
Bolger, C ;
Bojanic, S ;
Sheahan, NF ;
Coakley, D ;
Malone, JF .
VISION RESEARCH, 1999, 39 (11) :1911-1915
[2]   AMPLITUDE OF THE OCULAR PNEUMOPLETHYSMOGRAPHY WAVE-FORM IS CORRELATED WITH CARDIAC-OUTPUT [J].
BOSLEY, TM ;
COHEN, MS ;
GEE, W ;
REED, J ;
SERGOTT, RC ;
SAVINO, PJ .
STROKE, 1993, 24 (01) :6-9
[3]   OCULAR PNEUMOPLETHYSMOGRAPHY CAN HELP IN THE DIAGNOSIS OF GIANT-CELL ARTERITIS [J].
BOSLEY, TM ;
SAVINO, PJ ;
SERGOTT, RC ;
EAGLE, RC ;
SANDY, R ;
GEE, W .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (03) :379-381
[4]   Spectral-domain phase microscopy [J].
Choma, MA ;
Ellerbee, AK ;
Yang, CH ;
Creazzo, TL ;
Izatt, JA .
OPTICS LETTERS, 2005, 30 (10) :1162-1164
[5]   Wide band interferometry for thickness measurement [J].
Costantino, S ;
Martínez, OE ;
Torga, JR .
OPTICS EXPRESS, 2003, 11 (08) :952-957
[6]   Depth-resolved measurement of ocular fundus pulsations by low-coherence tissue interferometry [J].
Dragostinoff, Nikolaus ;
Werkmeister, Rene M. ;
Groeschl, Martin ;
Schmetterer, Leopold .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
[7]  
Drexler W, 1998, INVEST OPHTH VIS SCI, V39, P2140
[8]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[9]   Spectral content of the intraocular pressure pulse wave: glaucoma patients versus normal subjects [J].
Evans, DW ;
Hosking, SL ;
Embleton, SJ ;
Morgan, AJ ;
Bartlett, JD .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (06) :475-480
[10]   ARTERIAL VASCULAR COMPLIANCE RESPONSE TO VASODILATORS BY FOURIER AND PULSE CONTOUR ANALYSIS [J].
FINKELSTEIN, SM ;
COLLINS, VR ;
COHN, JN .
HYPERTENSION, 1988, 12 (04) :380-387