CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT

被引:245
作者
Gervaise, Alban [1 ,2 ]
Osemont, Benoit [2 ]
Lecocq, Sophie [2 ]
Noel, Alain [3 ]
Micard, Emilien [4 ,5 ]
Felblinger, Jacques [4 ,5 ]
Blum, Alain [2 ]
机构
[1] Hop Instruct Armees Legouest, Serv Imagerie Med, F-57070 Metz, France
[2] CHU NANCY, Serv Imagerie Guilloz, F-54035 Nancy, France
[3] Ctr Alexis Vautrin, CRAN UMR CNRS 7039, F-54511 Vandoeuvre Les Nancy, France
[4] CHU Nancy, INSERM, CIT 801, F-54511 Vandoeuvre Les Nancy, France
[5] CHU Nancy, INSERM, IADI, U947, F-54511 Vandoeuvre Les Nancy, France
关键词
Computed tomography; Multidetector CT; Dose reduction; Image quality; Iterative reconstruction; Lumbar spine; COMPUTED-TOMOGRAPHY; RADIATION; OPTIMIZATION; EXPOSURE;
D O I
10.1007/s00330-011-2271-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the impact of Adaptive Iterative Dose Reduction (AIDR) on image quality and radiation dose in phantom and patient studies. Methods A phantom was examined in volumetric mode on a 320-detector CT at different tube currents from 25 to 550 mAs. CT images were reconstructed with AIDR and with Filtered Back Projection (FBP) reconstruction algorithm. Image noise, Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR) and spatial resolution were compared between FBP and AIDR images. AIDR was then tested on 15 CT examinations of the lumbar spine in a prospective study. Again, FBP and AIDR images were compared. Image noise and SNR were analysed using a Wilcoxon signed-rank test. Results In the phantom, spatial resolution assessment showed no significant difference between FBP and AIDR reconstructions. Image noise was lower with AIDR than with FBP images with a mean reduction of 40%. CNR and SNR were also improved with AIDR. In patients, quantitative and subjective evaluation showed that image noise was significantly lower with AIDR than with FBP. SNR was also greater with AIDR than with FBP. Conclusion Compared to traditional FBP reconstruction techniques, AIDR significantly improves image quality and has the potential to decrease radiation dose. Key Points This study showed that Adaptive Iterative Dose Reduction (AIDR) reduces image noise. In a phantom image noise was reduced without altering spatial resolution. In patients AIDR reduced the image noise in lumbar spine CT. AIDR can potentially reduce the dose for lumbar spine CT by 52%.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 26 条
[1]   Radiation dose of cardiac computed tomography - what has been achieved and what needs to be done [J].
Alkadhi, Hatem ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2011, 21 (03) :505-509
[2]  
[Anonymous], 2007, 2007 CT MARK SUMM RE
[3]   Application of the noise power spectrum in modern diagnostic MDCT: Part II. Noise power spectra and signal to noise [J].
Boedeker, K. L. ;
McNitt-Gray, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) :4047-4061
[4]   Multidetector CT in patients suspected of having lumbar disk herniation: Comparison of standard-dose and simulated low-dose techniques [J].
Bohy, Pascale ;
de Maertelaer, Viviane ;
Roquigny, Aymeric ;
Keyzer, Caroline ;
Tack, Denis ;
Gevenois, Pierre Alain .
RADIOLOGY, 2007, 244 (02) :524-531
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation [J].
Christner, Jodie A. ;
Zavaletta, Vanessa A. ;
Eusemann, Christian D. ;
Walz-Flannigan, Alisa I. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W49-W55
[7]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[8]   Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures. [J].
Fazel, Reza ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Ross, Joseph S. ;
Chen, Jersey ;
Ting, Henry H. ;
Shah, Nilay D. ;
Nasir, Khurram ;
Einstein, Andrew J. ;
Nallamothu, Brahmajee K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (09) :849-857
[9]   Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results [J].
Gervaise, A. ;
Louis, M. ;
Batch, T. ;
Loeuille, D. ;
Noel, A. ;
Guillemin, F. ;
Blum, A. .
JOURNAL DE RADIOLOGIE, 2010, 91 (7-8) :779-785
[10]  
Ghetti C., 2011, PHYS MED