Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine

被引:8
作者
Anton, Alfonso [1 ,2 ,3 ]
Nolivos, Karen [4 ,5 ]
Pazos, Marta [6 ]
Fatti, Gianluca [3 ]
Ayala, Miriam Eleonora [1 ]
Martinez-Prats, Elena [7 ]
Peral, Oscar [8 ]
Poposki, Vladimir [1 ,3 ]
Tsiroukis, Evangelos [1 ]
Morilla-Grasa, Antonio [1 ]
Comas, Merce [5 ,9 ]
Castells, Xavier [5 ,9 ]
机构
[1] Inst Catala Retina ICR, Res Dept, Barcelona 08017, Spain
[2] Univ Int Catalunya, Med Sch, Barcelona 08017, Spain
[3] Parc De Salut Mar, Ophthalmol Serv, Barcelona 08005, Spain
[4] Inst Mar Invest Med IMIM, Dept Med, Barcelona 08005, Spain
[5] Parc Salut Mar, Epidmiol & Evaluat Dept, Barcelona 08005, Spain
[6] Hosp Clin Barcelona, Inst Clin Oftalmol ICOF, Inst Invest Med, Barcelona 08036, Spain
[7] Cap Barceloneta, Barcelona 08005, Spain
[8] Cap Villa Olimp, Barcelona 08005, Spain
[9] Inst Salud Carlos III, Hlth Serv Res Chron Patients Network REDISSEC, Madrid 28029, Spain
关键词
glaucoma; optical coherence tomography; retinography; telemedicine; screening; OPEN-ANGLE GLAUCOMA; NERVE-FIBER LAYER; COST-EFFECTIVENESS; IMAGING DEVICES; PREVALENCE; POPULATION; TESTS;
D O I
10.3390/jcm11010216
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fundus photograph and OCT images. Images were evaluated on a deferred basis. All participants were then invited to a complete glaucoma examination, including gonioscopy, visual field, and dilated fundus examination. The detection rate, sensitivity, specificity, and positive and negative predictive values were calculated. Results: We screened 1006 persons. Of these, 201 (19.9%) were classified as glaucoma suspects; 20.4% were identified only by retinographs, 11.9% only by OCT images, and 46.3% by both. On ophthalmic examination at the hospital (n = 481), confirmed glaucoma was found in 58 (12.1%), probable glaucoma in 76 (15.8%), and ocular hypertension in 10 (2.1%), and no evidence of glaucoma was found in 337 (70.0%). The detection rate for confirmed or probable glaucoma was 9.2%. Sensitivity ranged from 69.4% to 86.2% and specificity from 82.1% to 97.4%, depending on the definition applied. Conclusions: The combination of OCT images and fundus photographs yielded a detection rate of 9.2% in a population-based screening program with moderate sensitivity, high specificity, and predictive values of 84-96%.
引用
收藏
页数:11
相关论文
共 23 条
  • [1] Antón A, 2004, J GLAUCOMA, V13, P371
  • [2] Interobserver and Intertest Agreement in Telemedicine Glaucoma Screening with Optic Disk Photos and Optical Coherence Tomography
    Anton, Alfonso
    Nolivos, Karen
    Pazos, Marta
    Fatti, Gianluca
    Herranz, Alejandra
    Eleonora Ayala-Fuentes, Miriam
    Martinez-Prats, Elena
    Peral, Oscar
    Vega-Lopez, Zaida
    Monleon-Getino, Antoni
    Morilla-Grasa, Antonio
    Comas, Merce
    Castells, Xavier
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [3] Anton A, 2017, CLIN OPHTHALMOL, V11, P337, DOI 10.2147/OPTH.S120398
  • [4] Automated imaging technologies for the diagnosis of glaucoma: a comparative diagnostic study for the evaluation of the diagnostic accuracy, performance as triage tests and cost-effectiveness (GATE study)
    Azuara-Blanco, Augusto
    Banister, Katie
    Boachie, Charles
    McMeekin, Peter
    Gray, Joanne
    Burr, Jennifer
    Bourne, Rupert
    Garway-Heath, David
    Batterbury, Mark
    Hernandez, Rodolfo
    McPherson, Gladys
    Ramsay, Craig
    Cook, Jonathan
    [J]. HEALTH TECHNOLOGY ASSESSMENT, 2016, 20 (08) : 1 - +
  • [5] Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?
    Banister, Katie
    Boachie, Charles
    Bourne, Rupert
    Cook, Jonathan
    Burr, Jennifer M.
    Ramsay, Craig
    Garway-Heath, David
    Gray, Joanne
    McMeekin, Peter
    Hernandez, Rodolfo
    Azuara-Blanco, Augusto
    [J]. OPHTHALMOLOGY, 2016, 123 (05) : 930 - 938
  • [6] Beardsley Robert, 2017, Vision (Basel), V1, DOI 10.3390/vision1040024
  • [7] The clinical effectiveness and cost-effectiveness of screening for open angle glaucoma: a systematic review and economic evaluation
    Burr, Jm
    Mowatt, G.
    Hernandez, R.
    Siddiqui, Mar
    Cook, J.
    Lourenco, T.
    Ramsay, C.
    Vale, L.
    Fraser, C.
    Azuara-Blanco, A.
    Deeks, J.
    Cairns, J.
    Wormald, R.
    McPherson, S.
    Rabindranath, K.
    Grant, A.
    [J]. HEALTH TECHNOLOGY ASSESSMENT, 2007, 11 (41) : 1 - +
  • [8] Diagnostic accuracy of imaging devices in glaucoma: A meta-analysis
    Fallon, Monica
    Valero, Oliver
    Pazos, Marta
    Anton, Alfonso
    [J]. SURVEY OF OPHTHALMOLOGY, 2017, 62 (04) : 446 - 461
  • [9] The Impact of Tape Sealing Face Masks on Visual Field Scores in the Era of COVID-19: A Randomized Cross-over Study
    Heidinger, Astrid
    Falb, Thomas
    Werkl, Peter
    List, Wolfgang
    Hoeflechner, Lukas
    Riedl, Regina
    Ivastinovic, Domagoj
    Hommer, Anton
    Lindner, Ewald
    [J]. JOURNAL OF GLAUCOMA, 2021, 30 (10) : 878 - 881
  • [10] KLEIN BEK, 1992, OPHTHALMOLOGY, V99, P1499