Socket shield technique and delayed implant placement in maxilla: a series of five case reports

被引:1
作者
Shadid, Rola Muhammed [1 ]
机构
[1] Arab Amer Univ, Fac Dent, Dept Prosthodont, Jenin 240, Palestinian Ter, Palestine
关键词
Socket shield; Case series; Case repot; Delayed implant placement; DENTAL IMPLANT; AESTHETIC ZONE; EXTRACTION; BONE; IMMEDIATE; CRITERIA;
D O I
10.1186/s12903-022-02149-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Tooth extraction is often followed by remodeling of hard and soft tissues, while socket shield technique has been proposed to prevent or minimize this remodeling. Socket shield accompanied with delayed implant placement is a novel technique that could be used when delayed implantation is selected; however, more scientific based evidence is required to recommend this technique as everyday clinical practice. Thus, the aim of this case series was to assess the clinical, radiographic, and esthetic outcomes of the delayed placed implants associated with previously prepared socket shield at 3-15 months follow-up after loading. The stability of the shield and the depth of soft tissue penetration palatal to the shield at reentry of 3-6 months were also assessed. Cases presentation Five case reports of socket shield with delayed implant placement were described in the study. The facial shields were prepared and simultaneously the sockets were grafted with mineralized allograft particles, then the implants were placed 3-6 months later. Periodontal probe was used to measure the depth of soft tissue penetration palatal to the shield at reentry. Clinical indices of bleeding index, plaque index, and probing depths were recorded. Radiographic evaluation to record the amount of marginal bone loss post-loading, esthetic assessment using modified pink esthetic score, and patient assessed outcomes were also evaluated at 3-15 months follow-up after loading. At 3-6 months reentry, all shields were stable with maintenance of the facial bone and with extreme hard tissue formation in the sockets. All five implants were successful and functional without any pain or inflammation, with optimal soft tissue health and esthetics, and with minimal radiographic marginal bone loss at the last follow-up visit (3-15 months after loading). Conclusions Within the limits of this study, socket shield technique with delayed implant placement could be a predictable minimally invasive option for cases requiring delayed implant placement; however, a long-term well-designed clinical proof is warranted.
引用
收藏
页数:11
相关论文
共 50 条
[11]   Immediate Implant Combined With Vodified Socket-Shield Technique: A Case Letter [J].
Huang, Hong ;
Shu, Linjing ;
Liu, Yunfei ;
Wang, Li ;
Li, Jiao ;
Fu, Gang .
JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (02) :139-143
[12]   Radiographic and Esthetic Evaluation Following Immediate Implant Placement with or without Socket Shield and Delayed Implant Placement Following Socket Preservation in the Maxillary Esthetic Region - A Randomized Controlled Clinical Trial [J].
Santhanakrishnan, Muthukumar ;
Subramanian, Vedavalli ;
Ramesh, Nithyakalyani ;
Kamaleeshwari, R. .
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2021, 13 :479-494
[13]   Preserving Peri-Implant Soft Tissue Health: A Case Report on Immediate Implant Placement Using the Socket Shield Technique [J].
Shanmugam, Mohanasatheesh ;
Balaji, Anitha ;
Valiathan, Mohan ;
Kannan, Rudhra ;
Samuel, Angelin fiona Jeyaraj .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
[14]   Socket Shield Technique for immediate implant placement - clinical, radiographic and volumetric data after 5 years [J].
Baeumer, Daniel ;
Zuhr, Otto ;
Rebele, Stephan ;
Huerzeler, Markus .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) :1450-1458
[15]   Socket Shield Technique to Improve the Outcomes of Immediate Implant: A Systematic Review and Meta-Analysis [J].
Scarano, Antonio ;
Di Carmine, Mariastella ;
Al-Hamed, Faez Saleh ;
Khater, Ahmad G. A. ;
Gehrke, Sergio Alexandre ;
Tari, Sergio Rexhep ;
Leo, Lucia ;
Inchingolo, Francesco ;
Lorusso, Felice .
PROSTHESIS, 2023, 5 (02) :509-526
[16]   The socket shield technique for immediate implant placement: A systematic review and meta-analysis [J].
Atieh, Momen A. ;
Shah, Maanas ;
Abdulkareem, Mohammed ;
AlQahtani, Haif A. ;
Alsabeeha, Nabeel H. M. .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (08) :1186-1200
[17]   A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report [J].
Lahham, Cezar ;
Lahham, Elias Edward ;
Abu Ali, Ali .
JOURNAL OF SURGICAL CASE REPORTS, 2023, 2023 (08)
[18]   Effectiveness of the socket shield technique in dental implant: A systematic review [J].
Ogawa, Toru ;
Sitalaksmi, Ratri M. ;
Miyashita, Makiko ;
Maekawa, Kenji ;
Ryu, Masahiro ;
Kimura-Ono, Aya ;
Suganuma, Takeshi ;
Kikutani, Takeshi ;
Fujisawa, Masanori ;
Tamaki, Katsushi ;
Kuboki, Takuo .
JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) :12-18
[19]   Effect of SagittalRoot Position, Angle, and Bone Thickness on Peri-implant Tissue Phenotype and Bone Level in Socket Shield Technique: A Retrospective Case Series [J].
Gurbuz, Ezgi ;
Ceylan, Ezgi ;
Ersoz, Mehmet Meric ;
Keceli, Huseyin Gencay .
JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (04) :308-316
[20]   Socket shield technique vs conventional immediate implant placement with immediate temporization. Randomized clinical trial [J].
Abd-Elrahman, Ahmed ;
Shaheen, Mostafa ;
Askar, Niveen ;
Atef, Mohammed .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (05) :602-611