Fully automated single-use stirred-tank bioreactors for parallel microbial cultivations

被引:58
作者
Kusterer, Andreas [1 ]
Krause, Christian [2 ]
Kaufmann, Klaus [3 ]
Arnold, Matthias [4 ]
Weuster-Botz, Dirk [1 ]
机构
[1] Tech Univ Munich, Lehrstuhl Bioverfahrenstech, D-85748 Garching, Germany
[2] Precis Sensing GmbH, D-93053 Regensburg, Germany
[3] AW E, D-81827 Munich, Germany
[4] DASGIP AG, D-52428 Julich, Germany
关键词
fermentation; stirred-tank; microbioreactor; stirrer-speed; pH; dissolved oxygen; fluorescence decay time;
D O I
10.1007/s00449-007-0195-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Single-use stirred tank bioreactors on a 10-mL scale operated in a magnetic-inductive bioreaction block for 48 bioreactors were equipped with individual stirrer-speed tracing, as well as individual DO- and pH-monitoring and control. A Hall-effect sensor system was integrated into the bioreaction block to measure individually the changes in magnetic field density caused by the rotating permanent magnets. A restart of the magnetic inductive drive was initiated automatically each time a Hall-effect sensor indicates one non-rotating gas-inducing stirrer. Individual DO and pH were monitored online by measuring the fluorescence decay time of two chemical sensors immobilized at the bottom of each single-use bioreactor. Parallel DO measurements were shown to be very reliable and independently from the fermentation media applied in this study for the cultivation of Escherichia coli and Saccharomyces cerevisiae. The standard deviation of parallel pH measurements was pH 0.1 at pH 7.0 at the minimum and increased to a standard deviation of pH 0.2 at pH 6.0 or at pH 8.5 with the complex medium applied for fermentations with S. cerevisiae. Parallel pH-control was thus shown to be meaningful with a tolerance band around the pH set-point of +/- pH 0.2 if the set-point is pH 6.0 or lower.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 22 条
[1]   Long-term monitoring of bacteria undergoing programmed population control in a microchemostat [J].
Balagaddé, FK ;
You, LC ;
Hansen, CL ;
Arnold, FH ;
Quake, SR .
SCIENCE, 2005, 309 (5731) :137-140
[2]   Characterization and application of a miniature 10 mL stirred-tank bioreactor, showing scale-down equivalence with a conventional 7 L reactor [J].
Betts, Jonathan I. ;
Doig, Steven D. ;
Baganz, Frank .
BIOTECHNOLOGY PROGRESS, 2006, 22 (03) :681-688
[3]   Differential gene expression profiles and real-time measurements of growth parameters in Saccharomyces cerevisiae grown in microliter-scale bioreactors equipped with internal stirring [J].
Boccazzi, Paolo ;
Zhang, Zhiyu ;
Kurosawa, Kazuhiko ;
Szita, Nicolas ;
Bhattacharya, Sanchita ;
Jensen, Klavs F. ;
Sinskey, Anthony J. .
BIOTECHNOLOGY PROGRESS, 2006, 22 (03) :710-717
[4]   Reaction engineering studies on β-ketoester reductions with whole cells of recombinant Saccharomyces cerevisiae [J].
Engelking, H ;
Pfaller, R ;
Wich, G ;
Weuster-Botz, D .
ENZYME AND MICROBIAL TECHNOLOGY, 2006, 38 (3-4) :536-544
[5]   Design and performance of a 24-station high throughput microbioreactor [J].
Harms, P ;
Kostov, Y ;
French, JA ;
Soliman, M ;
Anjanappa, M ;
Ram, A ;
Rao, G .
BIOTECHNOLOGY AND BIOENGINEERING, 2006, 93 (01) :6-13
[6]   Scale-down and parallel operation of the riboflavin production process with Bacillus subtilis [J].
Knorr, Bettina ;
Schlieker, Heinrich ;
Hohmann, Hans-Peter ;
Weuster-Botz, Dirk .
BIOCHEMICAL ENGINEERING JOURNAL, 2007, 33 (03) :263-274
[7]  
Kostov Y, 2001, BIOTECHNOL BIOENG, V72, P346, DOI 10.1002/1097-0290(20010205)72:3<346::AID-BIT12>3.0.CO
[8]  
2-X
[9]   Design of a prototype miniature bioreactor for high throughput automated bioprocessing [J].
Lamping, SR ;
Zhang, H ;
Allen, B ;
Shamlou, PA .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (3-6) :747-758
[10]   Microbioreactor arrays with integrated mixers and fluid injectors for high-throughput experimentation with pH and dissolved oxygen control [J].
Lee, Harry L. T. ;
Boccazzi, Paolo ;
Ram, Rajeev J. ;
Sinskey, Anthony J. .
LAB ON A CHIP, 2006, 6 (09) :1229-1235