Heartbeat-Induced Axial Motion Artifacts in Optical Coherence Tomography Measurements of the Retina

被引:61
作者
de Kinkelder, Roy [1 ,3 ]
Kalkman, Jeroen [1 ]
Faber, Dirk J. [1 ,2 ]
Schraa, Olaf [4 ]
Kok, Pauline H. B. [2 ]
Verbraak, Frank D. [1 ,2 ]
van Leeuwen, Ton G. [1 ,5 ,6 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1100 DE Amsterdam, Netherlands
[3] Topcon Europe Med BV, Capelleaan Den Ijssel, Netherlands
[4] BMEYE, Amsterdam, Netherlands
[5] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
[6] Univ Twente, Fac Sci & Technol, Biomed Photon Imaging Grp, NL-7500 AE Enschede, Netherlands
关键词
BLOOD-FLOW; IN-VIVO; DOPPLER TOMOGRAPHY; EYE LENGTH; CANCER;
D O I
10.1167/iovs.10-6738
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the cause of axial eye motion artifacts that occur in optical coherence tomography (OCT) imaging of the retina. Understanding the cause of these motions can lead to improved OCT image quality and therefore better diagnoses. METHODS. Twenty-seven measurements were performed on 5 subjects. Spectral domain OCT images at the macula were collected over periods up to 30 seconds. The axial shift of every average A-scan was calculated with respect to the previous average A-scan by calculating the cross-correlation. The frequency spectrum of the calculated shifts versus time was determined. The heart rate was determined from blood pressure measurements at the finger using an optical blood pressure detector. The fundamental frequency and higher order harmonics of the axial OCT shift were compared with the frequency spectrum of blood pressure data. In addition, simultaneous registration of the movement of the cornea and the retina was performed with a dual reference arm OCT setup, and movements of the head were also analyzed. RESULTS. A correlation of 0.90 was found between the fundamental frequency in the axial OCT shift and the heart rate. Cornea and retina move simultaneously in the axial direction. The entire head moves with the same amplitude as the retina. CONCLUSIONS. Axial motion artifacts during OCT volume scanning of the retina are caused by movements of the whole head induced by the heartbeat. (Invest Ophthalmol Vis Sci. 2011; 52: 3908-3913) DOI: 10.1167/iovs.10-6738
引用
收藏
页码:3908 / 3913
页数:6
相关论文
共 27 条
  • [1] MR ARTIFACTS - A REVIEW
    BELLON, EM
    HAACKE, EM
    COLEMAN, PE
    SACCO, DC
    STEIGER, DA
    GANGAROSA, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) : 1271 - 1281
  • [2] A study comparing ocular pressure pulse and ocular fundus pulse in dependence of axial eye length and ocular volume
    Berisha, Fatmire
    Findl, Oliver
    Lasta, Michael
    Kiss, Barbara
    Schmetterer, Leopold
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (07) : 766 - 772
  • [3] A New Generation of Optical Diagnostics for Bladder Cancer: Technology, Diagnostic Accuracy, and Future Applications
    Cauberg, Evelyne C. C.
    de Bruin, Daniel M.
    Faber, Dirk J.
    van Leeuwen, Ton G.
    de la Rosette, Jean J. M. C. H.
    de Reijke, Theo M.
    [J]. EUROPEAN UROLOGY, 2009, 56 (02) : 287 - 296
  • [4] Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography
    Chen, ZP
    Milner, TE
    Srinivas, S
    Wang, XJ
    Malekafzali, A
    vanGemert, MJC
    Nelson, JS
    [J]. OPTICS LETTERS, 1997, 22 (14) : 1119 - 1121
  • [5] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [6] Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    de Boer, JF
    Cense, B
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    [J]. OPTICS LETTERS, 2003, 28 (21) : 2067 - 2069
  • [7] Optical phantoms of varying geometry based on thin building blocks with controlled optical properties
    de Bruin, Daniel M.
    Bremmer, Rolf H.
    Kodach, Vitali M.
    de Kinkelder, Roy
    van Marle, Jan
    van Leeuwen, Ton G.
    Faber, Dirk J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [8] Depth-resolved measurement of ocular fundus pulsations by low-coherence tissue interferometry
    Dragostinoff, Nikolaus
    Werkmeister, Rene M.
    Groeschl, Martin
    Schmetterer, Leopold
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [9] Tracking optical coherence tomography
    Ferguson, RD
    Hammer, DX
    Paunescu, LA
    Beaton, S
    Schuman, JS
    [J]. OPTICS LETTERS, 2004, 29 (18) : 2139 - 2141
  • [10] HUMAN GAZE STABILITY IN THE HORIZONTAL VERTICAL AND TORSIONAL DIRECTION DURING VOLUNTARY HEAD MOVEMENTS, EVALUATED WITH A THREE-DIMENSIONAL SCLERAL INDUCTION COIL TECHNIQUE
    FERMAN, L
    COLLEWIJN, H
    JANSEN, TC
    VANDENBERG, AV
    [J]. VISION RESEARCH, 1987, 27 (05) : 811 - +