Trueness of removable partial denture frameworks additively manufactured with selective laser melting

被引:32
作者
Peng, Pei-Wen [1 ]
Hsu, Ching-Ying [2 ]
Huang, Huei-Yu [3 ,4 ]
Chao, Jen-Chih [1 ]
Lee, Wei-Fang [1 ]
机构
[1] Taipei Med Univ, Sch Dent Technol, Taipei, Taiwan
[2] Taipei Med Univ Hosp, Dept Dent, Div Prosthodont, Taipei, Taiwan
[3] Taipei Med Univ, Sch Dent, Taipei, Taiwan
[4] Taipei Med Univ, Dept Dent, Shuang Ho Hosp, New Taipei, Taiwan
关键词
COMPUTER-AIDED-DESIGN; FABRICATION; ACCURACY; ALLOYS; FUTURE; CASTS;
D O I
10.1016/j.prosdent.2020.06.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although studies have reported on selective laser melting (SLM)-fabricated removable partial dentures (RPDs), research addressing the trueness of SLM-fabricated RPD metal frameworks is sparse. Purpose. The purpose of this in vitro study was to evaluate the trueness of powdered cobalt- chromium (Co-Cr) or titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy frameworks for RPDs fabricated by SLM. Material and methods. A digital scan of a Kennedy class II mandible typodont was obtained to design an RPD framework by using a computer-aided design (CAD) software program (denoted as CRF). Two experimental groups of frameworks were fabricated from the CRF by using SLM in alloys of Co-Cr (SLM-Co-Cr, n=6) and in Ti-6Al-4V (SLM-Ti-6Al-4V, n=6) while a control group was fabricated by using traditional lost-wax casting following stereolithography (CA-Co-Cr, n=6). In total, 18 RPD frameworks were digitally scanned (denoted as CRF), with each scan then superimposed on the CRF and evaluated for discrepancies by using a 3D analysis software program. A nonparametric Kruskal-Wallis test was performed to determine differences in trueness among groups (alpha=.05). Results. The CA-Co-Cr group showed the highest discrepancy between CEF and CRF. Statistically significant differences were found between the CA-Co-Cr and SLM-fabricated groups (P=.03 for Co-Cr, and P=.016 for Ti-6Al-4V). However, no significant difference was found between the SLM-Co-Cr and SLM-Ti-6Al-4V groups (P=.787). Conclusions. SLM-fabricated RPD frameworks exhibited higher trueness than CA-Co-Cr fabricated ones, indicating the potential of selective laser melting to produce the geometric shapes required for accurate dental restorations.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 30 条
  • [1] Direct selective laser sintering of metals
    Agarwala, Mukesh
    Bourell, David
    Beaman, Joseph
    Marcus, Harris
    Barlow, Joel
    [J]. RAPID PROTOTYPING JOURNAL, 1995, 1 (01) : 26 - 36
  • [2] Ali AO., 2015, Dentistry, V5, P300, DOI [10.4172/2161-1122.1000300., DOI 10.4172/2161-1122.1000300]
  • [3] In vitro corrosion analyses of heat treated cobalt-chromium alloys manufactured by direct metal laser sintering
    Alifui-Segbaya, Frank
    Lewis, Jeffrey
    Eggbeer, Dominic
    Williams, Robert John
    [J]. RAPID PROTOTYPING JOURNAL, 2015, 21 (01) : 111 - 116
  • [4] Bending properties of strengthened Ti-6Al-7Nb alloy major connectors compared to Co-Cr alloy major connectors
    Aridome, K
    Yamazaki, M
    Baba, K
    Ohyama, T
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (03) : 267 - 273
  • [5] The evolution of rapid prototyping in dentistry: a review
    Azari, Abbas
    Nikzad, Sakineh
    [J]. RAPID PROTOTYPING JOURNAL, 2009, 15 (03) : 216 - 225
  • [6] Rapid manufacture of removable partial denture frameworks
    Bibb, Richard
    Eggbeer, Dominic
    Williams, Robert
    [J]. RAPID PROTOTYPING JOURNAL, 2006, 12 (02) : 95 - 99
  • [7] Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study
    Braian, Michael
    Jonsson, David
    Kevci, Mir
    Wennerberg, Ann
    [J]. DENTAL MATERIALS, 2018, 34 (07) : 978 - 993
  • [8] Fabrication of Removable Partial Denture Framework by Selective Laser Melting
    Chen, Guangxia
    Zeng, Xiaoyan
    Wang, Zemin
    Guan, Kai
    Peng, Changwen
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 174 - +
  • [9] Comparison of accuracy and reproducibility of casts made by digital and conventional methods
    Cho, Seok-Hwan
    Schaefer, Oliver
    Thompson, Geoffrey A.
    Guentsch, Arndt
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) : 310 - 315
  • [10] A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies
    Dunham, D
    Brudvik, JS
    Morris, WJ
    Plummer, KD
    Cameron, SM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (04) : 323 - 326