Single-Use Disposable Electrochemical Label-Free Immunosensor for Detection of Glycated Hemoglobin (HbA1c) Using Differential Pulse Voltammetry (DPV)

被引:41
|
作者
Molazemhosseini, Alireza [1 ]
Magagnin, Luca [1 ]
Vena, Pasquale [1 ]
Liu, Chung-Chiun [2 ,3 ]
机构
[1] Politecn Milan, Dipartimento Chim Mat & Ingn Chim Giulio Natta, Via Mancinelli 7, I-20131 Milan, Italy
[2] Case Western Reserve Univ, Dept Chem & Biomol Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Ctr Elect Design, 10900 Euclid Ave, Cleveland, OH 44106 USA
关键词
immunosensor; HbA1c; differential pulse voltammetry; 3-MPA; SELF-ASSEMBLED MONOLAYERS; BORONIC ACID; HBA(1C); INTERFACE; BINDING; SENSOR;
D O I
10.3390/s16071024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single-use disposable in vitro electrochemical immunosensor for the detection of HbA1c in undiluted human serum using differential pulse voltammetry (DPV) was developed. A three-electrode configuration electrochemical biosensor consisted of 10-nm-thin gold film working and counter electrodes and a thick-film printed Ag/AgCl reference electrode was fabricated on a polyethylene terephthalate (PET) substrate. Micro-fabrication techniques including sputtering vapor deposition and thick-film printing were used to fabricate the biosensor. This was a roll-to-roll cost-effective manufacturing process making the single-use disposable in vitro HbA1c biosensor a reality. Self-assembled monolayers of 3-Mercaptopropionic acid (MPA) were employed to covalently immobilize anti-HbA1c on the surface of gold electrodes. Electrochemical impedance spectroscopy (EIS) and X-ray photoelectron spectroscopy (XPS) confirmed the excellent coverage of MPA-SAM and the upward orientation of carboxylic groups. The hindering effect of HbA1c on the ferricyanide/ferrocyanide electron transfer reaction was exploited as the HbA1c detection mechanism. The biosensor showed a linear range of 7.5-20 mu g/mL of HbA1c in 0.1 M PBS. Using undiluted human serum as the test medium, the biosensor presented an excellent linear behavior (R-2 = 0.999) in the range of 0.1-0.25 mg/mL of HbA1c. The potential application of this biosensor for in vitro measurement of HbA1c for diabetic management was demonstrated.
引用
收藏
页数:11
相关论文
共 28 条
  • [1] Label-free electrochemical detection of glucose and glycated hemoglobin (HbA1c)
    Thapa, Mukesh
    Heo, Yun Seok
    BIOSENSORS & BIOELECTRONICS, 2023, 221
  • [2] Label-free electrochemical detection of glycated hemoglobin (HbA1c) and C-reactive protein (CRP) to predict the maturation of coronary heart disease due to diabetes
    Grewal, Rehmat
    Ortega, Greter A.
    Geng, Fei
    Srinivasan, Seshasai
    Rajabzadeh, Amin Reza
    BIOELECTROCHEMISTRY, 2024, 159
  • [3] Label-free Electrochemical Biosensor for Glycated Hemoglobin (HbA1c) and Glycated Albumin (GA) Measurement Using 4-mercapto-phenyl Boronic Acid Embedded Affinity
    Thapa, Mukesh
    Heo, Yun Seok
    BIOCHIP JOURNAL, 2025,
  • [4] A disposable electrochemical sensor designed to estimate glycated hemoglobin (HbA1c) level in whole blood
    Thiruppathi, Murugan
    Lee, Ju-Fang
    Chen, Cheng Che
    Ho, Ja-an Annie
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [5] A CRISPR-amplified label-free electrochemical aptasensor for the sensitive detection of HbA1c
    Ma, Jianfeng
    Zheng, Youwei
    Xie, Yaoyao
    Zhu, Dan
    Wang, Lianhui
    Su, Shao
    SENSORS & DIAGNOSTICS, 2024, 3 (08): : 1247 - 1252
  • [6] Label-free nanostructured sensor for the simple determination of glycosylated hemoglobin (HbA1c)
    Thea, Rocio
    Onna, Diego
    Kreuzer, Mark P.
    Hamer, Mariana
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 297
  • [7] Electrochemical aptasensor for ultrasensitive detection of glycated hemoglobin (HbA1c) using gold-modified SPCE
    Zuliska, Serly
    Irkham
    Zakiyyah, Salma Nur
    Hartati, Yeni Wahyuni
    Einaga, Yasuaki
    Maksum, Iman Permana
    SENSING AND BIO-SENSING RESEARCH, 2025, 47
  • [8] Electrochemical Direct Detection of Glycated Hemoglobin (HbA1c) by Immobilized Glucose Oxidase on ZnO Nanostructures
    Koohsorkhi, Javad
    Kafi, Mehrshad
    Sanjari, Sajjad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2024, 16 (04): : 315 - 330
  • [9] A sensitive and disposable indium tin oxide based electrochemical immunosensor for label-free detection of MAGE-1
    Demirbakan, Burcak
    Sezginturk, Mustafa Kemal
    TALANTA, 2017, 169 : 163 - 169
  • [10] Detection of 17 -Estradiol in Environmental Samples and for Health Care Using a Single-Use, Cost-Effective Biosensor Based on Differential Pulse Voltammetry (DPV)
    Dai, Yifan
    Liu, Chung Chiun
    BIOSENSORS-BASEL, 2017, 7 (02):