Fault ride-through capability of a DFIG in isolated grids employing DVR and supercapacitor energy storage

被引:33
作者
Gkavanoudis, Spyros I. [1 ]
Demoulias, Charis S. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, Thessaloniki 54124, Greece
关键词
Doubly-Fed Induction Generator; Fault ride-through Dynamic Voltage Restorer; Stand-alone operation; Synchronous generator; Power quality; DYNAMIC VOLTAGE RESTORER; BACK PWM CONVERTERS; WIND TURBINES; GENERATION SYSTEM; CONTROL STRATEGY; LOAD;
D O I
10.1016/j.ijepes.2014.12.068
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to utilize Doubly Fed Induction Generators (DFIGs) as primary power source in an isolated system, they should be able to regulate the voltage and frequency of the system as well as ride-through faults. This paper proposes a new control strategy for a DFIG operating in an isolated power system, accomplished by a Dynamic Voltage Restorer (DVR) and a Supercapacitor Energy Storage System (SCESS), in order to ride through symmetrical and asymmetrical faults. During faults, the DFIG continues to operate normally, while the active power mismatch is handled by the SCESS. In particular, during asymmetrical faults, the DFIG and the DVR are properly controlled in order to feed the non-faulty phases uninterruptedly. When integrated in a power system with conventional synchronous generators, the proposed control strategy improves the Fault Ride-Through (FRT) capability of a DFIG, while providing frequency and voltage support to the system throughout the fault duration. Thus, the transient stability of the power system is significantly improved. The effectiveness of the proposed control method under different fault conditions is verified by detailed simulation results. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 27 条
[21]   Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation [J].
Pena, R ;
Clare, JC ;
Asher, GM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (03) :231-241
[22]   Control strategy for a Doubly-Fed Induction Generator feeding an unbalanced grid or stand-alone load [J].
Pena, Ruben ;
Cardenas, Roberto ;
Escobar, Enrique ;
Clare, Jon ;
Wheeler, Pat .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) :355-364
[23]   Supercapacitor energy storage system for fault ride-through of a DFIG wind generation system [J].
Rahim, A. H. M. A. ;
Nowicki, E. P. .
ENERGY CONVERSION AND MANAGEMENT, 2012, 59 :96-102
[24]   Microgrid Dynamic Performance Improvement Using a Doubly Fed Induction Wind Generator [J].
Shahabi, M. ;
Haghifam, M. R. ;
Mohamadian, M. ;
Nabavi-Niaki, S. A. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) :137-145
[25]   Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics [J].
Tu, X. ;
Dessaint, L. -A. ;
El Kahel, M. ;
Barry, A. .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2006, 71 (4-6) :425-439
[26]   Performance Enhancement of Stand-Alone DFIG Systems With Control of Rotor and Load Side Converters Using Resonant Controllers [J].
Van-Tung Phan ;
Lee, Hong-Hee .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (01) :199-210
[27]  
Zheng Z, 2012, PROC IEEE INT SYMP, P1072, DOI [10.1109/ICALIP.2012.6376775, 10.1109/ISIE.2012.6237237]