Diagnostic accuracy of a LAMP kit for diagnosis of imported malaria in Switzerland

被引:26
作者
Marti, Hanspeter [1 ,2 ]
Stalder, Chris [1 ,2 ]
Gonzalez, Iveth J. [3 ]
机构
[1] Univ Basel, Basel, Switzerland
[2] Swiss Trop & Publ Hlth Inst Swiss TPH, Med & Diagnost Dept, CH-4002 Basel, Switzerland
[3] Fdn Innovat New Diagnost, CH-1211 Geneva, Switzerland
关键词
Malaria; Diagnosis; LAMP; qPCR; MEDIATED ISOTHERMAL AMPLIFICATION; DAR-ES-SALAAM; FALCIPARUM-MALARIA; PERFORMANCE; MICROSCOPY; TESTS; BLOOD; ASSAY;
D O I
10.1016/j.tmaid.2014.12.016
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The diagnosis of acute malaria in non-endemic countries is still carried out largely by microscopic examination of thick and thin smears or rapid diagnostic tests. Low-density infections might be missed, however, but the more sensitive PCR is more expensive, complex and requires considerable more time. Method: We examined the suitability of a new loop-mediated isothermal DNA-amplification kit (LAMP) for malaria diagnosis in febrile returning travellers in comparison to qPCR and microscopic examination in a prospective study in a non-endemic setting at the Swiss TPH. Results: Among 205 complete datasets, 43 samples were positive for malaria by microscopy, with Plasmodium falciparum (35 cases) being the most frequent species. All these samples were positive by both LAMP and qPCR, too. An additional 4 samples negative by microscopy were positive by both LAMP and qPCR. Three of these samples were follow-up samples taken after start of treatment in patients originally identified as positive by microscopy. Conclusions: The LAMP performed exactly as did the qPCR and is a very valuable diagnostic alternative with a potential of being used also in endemic settings. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 171
页数:5
相关论文
共 50 条
  • [31] Imported human rabies in Switzerland, 2012: A diagnostic conundrum
    Deubelbeiss, A. N.
    Trachsel, Ch.
    Bachli, E. B.
    Kuffer, A.
    Budka, H.
    Eniseyskiy, P.
    Zimmermann, H.
    Wallace, R. M.
    Farley, S.
    Zanoni, R. G.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (02) : 178 - 181
  • [32] The Importance of Accuracy in Diagnosis of Positive Malaria Cases in a Country Progressing Towards Malaria Elimination
    Fernando, Sumadhya Deepika
    Navaratne, Chathuri J.
    Galappaththy, Gawrie N. L.
    Abeyasinghe, Rabindra R.
    Silva, Nilupa
    Wickermasinghe, Renu
    [J]. JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2013, 5 (04) : 127 - 130
  • [33] DIAGNOSIS OF MALARIA IN A TRAVELER 9 MONTHS AFTER RETURNING FROM WEST AFRICA BY ILLUMIGENE® LAMP ASSAY: A CASE REPORT
    Reuken, Philipp A.
    Baier, Michael
    Hagel, Stefan
    Eisermann, Philip
    Stallmach, Andreas
    Roedel, Juergen
    [J]. ACTA MICROBIOLOGICA ET IMMUNOLOGICA HUNGARICA, 2019, 66 (03) : 301 - 306
  • [34] Loop-mediated isothermal amplification (LAMP) test for diagnosis of uncomplicated malaria in endemic areas: a meta-analysis of diagnostic test accuracy
    Denesh Selvarajah
    Cho Naing
    Norah Htet Htet
    Joon Wah Mak
    [J]. Malaria Journal, 19
  • [35] Diagnosis of malaria parasitemia in children using a rapid diagnostic test
    Adesanmi, T. A.
    Okafor, H. U.
    Okoro, A. B.
    Mafe, A. G.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2011, 14 (02) : 195 - 200
  • [36] Performance evaluation of different strategies based on microscopy techniques, rapid diagnostic test and molecular loop-mediated isothermal amplification assay for the diagnosis of imported malaria
    Charpentier, E.
    Benichou, E.
    Pages, A.
    Chauvin, P.
    Fillaux, J.
    Valentin, A.
    Guegan, H.
    Guemas, E.
    Salabert, A-S
    Armengol, C.
    Menard, S.
    Cassaing, S.
    Berry, A.
    Iriart, X.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2020, 26 (01) : 115 - 121
  • [37] Malaria cases in Switzerland from 2005 to 2015 and recent rise of imported Plasmodium vivax malaria
    Gilles, Eperon
    Sophie, Durieux-Paillard
    Anne, Mauris
    Francois, Chappuis
    Nicole, Gysin
    [J]. SWISS MEDICAL WEEKLY, 2017, 147
  • [38] Investigation of LAMP Technique in Diagnosis Type of Plasmodium Species in Anopheles Mosquitoes :A Fast and Practical Technique to Detect Malaria Pathogens in the Field
    Mirahmadi, Hadi
    Kazemipour, Nadia
    Yazdiani, Anis
    Mehravaran, Ahmad
    Basseri, Hamid Reza
    Mohammadi, Leili
    Alijani, Ebrahim
    [J]. ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2021, 31 (04) : 743 - 752
  • [39] Performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia
    Tegegne, Banchamlak
    Getie, Sisay
    Lemma, Wossenseged
    Mohon, Abu Naser
    Pillai, Dylan R.
    [J]. MALARIA JOURNAL, 2017, 16 : 1 - 7
  • [40] Improvements in DNA Extraction and Loop-Mediated Isothermal Amplification (LAMP) Assist Application of LAMP on Malaria Point-of-Care Diagnostic Devices
    Han Ly
    Thanh-Xuan Le
    Hoang-Tuan Nguyen
    Vo Van Toi
    Thanh-Dong Le
    Thuy-Vy Pham-Nguyen
    Perrault, Cecile M.
    Khon Huynh
    [J]. 7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES, 2020, 69 : 333 - 336