Crutch Weightbearing on Comminuted Humeral Shaft Fractures: A Biomechanical Comparison of Large versus Small Fragment Fixation for Humeral Shaft Fractures

被引:13
作者
Patel, Ravi [1 ]
Neu, Corey P. [2 ]
Curtiss, Shane
Fyhrie, David P.
Yoo, Brad [1 ]
机构
[1] Univ Calif Davis, Davis Med Ctr, Dept Orthopaed, Sacramento, CA 95817 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
humerus fracture; internal fixation; weightbearing; INTERNAL-FIXATION; PLATE FIXATION; BONE; STABILITY; SCREWS; STIFFNESS; STRENGTH; NUMBER;
D O I
10.1097/BOT.0b013e3181df968c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study evaluated the failure properties of length unstable humerii secured with small or large fragment plates. Methods: Two nonlocking plate constructs were examined, a nine-hole 4.5-mm limited contact dynamic compression plate (large fragment group) and a 12-hole 3.5-mm limited contact dynamic compression plate (small fragment group), both on composite humerii with a 1-cm defect to simulate comminution (n = 12 for each group). Each plate construct had similar working lengths and number of fixation points. Mechanical testing was first randomized for stiffness measurements in axial and torsional loads. All constructs were then tested in cyclic axial loads to failure. Results: For axial testing, the large fragment group had a mean stiffness of 1020 +/- 195 N/mm compared with 268 +/- 67 N/mm in the small fragment group (P < 0.0001). For torsional testing, the large fragment group had a mean stiffness of 1.5 +/- 0.05 Nm/degree compared with 0.9 +/- 0.04 Nm/degree in the small fragment group (P < 0.0001). Plastic deformation in the large fragment and small fragment groups were 0.09 +/- 0.07 mm and 0.20 +/- 0.24 mm, respectively (P = 0.1) assessed during cyclic testing up to 300 N. The postcyclic yield force in the large fragment group was 227 +/- 30 N and in the small fragment group was 153 +/- 5 N (P < 0.0001). The ultimate load in the large fragment and small fragment groups were 800 +/- 87 N and 307 +/- 15 N, respectively. Conclusion: The results corroborate anticipated plate mechanical behavior with plate stiffness increasing as both plate width and thickness increase. The calculated yield force data suggest that both small and large fragment constructs would experience plastic deformation during bilateral crutch ambulation in a patient weighing 50 kg or more. The large fragment construct is not expected to catastrophically fail when subjected to loads in a patient 90 kg or less. The small fragment construct is predicted to catastrophically fail in patients weighing 70 kg or more.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 30 条
  • [11] Guidelines for the clinical application of the LCP
    Gautier, E
    Sommer, C
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : 63 - 76
  • [12] SURGICAL-TREATMENT OF HUMERAL SHAFT FRACTURES - THE BASEL EXPERIENCE
    HEIM, D
    HERKERT, F
    HESS, P
    REGAZZONI, P
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (02) : 226 - 232
  • [13] The effect of plate rotation on the stiffness of femoral LISS: A mechanical study
    Khalafi, Afshin
    Curtiss, Shane
    Hazelwood, Scott
    Wolinsky, Philip
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) : 542 - 546
  • [14] McKee MD, 2006, ROCKWOOD GREENS FRAC
  • [15] Are Locking Screws Advantageous with Plate Fixation of Humeral Shaft Fractures? A Biomechanical Analysis of Synthetic and Cadaveric Bone
    O'Toole, Robert V.
    Andersen, Romney C.
    Vesnovsky, Oleg
    Alexander, Melvin
    Topoleski, L. D. Timmie
    Nascone, Jason W.
    Sciadini, Marcus F.
    Turen, Clifford
    Eglseder, W. Andrew, Jr.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (10) : 709 - 715
  • [16] PERREN S, 1991, MANUAL INTERNAL FIXA, pP1
  • [17] Evolution of the internal fixation of long bone fractures - The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    Perren, SM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08): : 1093 - 1110
  • [18] ROMMENS PM, 1989, UNFALLCHIRURG, V92, P565
  • [19] Open reduction and internal fixation of humeral nonunions - A biomechanical and clinical study
    Rubel, IF
    Kloen, P
    Campbell, D
    Schwartz, M
    Liew, A
    Myers, E
    Helfet, DL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (08) : 1315 - 1322
  • [20] Minimal versus maximal plate fixation techniques of the ulna: The biomechanical effect of number of screws and plate length
    Sanders, R
    Haidukewych, GJ
    Milne, T
    Dennis, J
    Latta, LL
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (03) : 166 - 171