Crutch Weightbearing on Comminuted Humeral Shaft Fractures: A Biomechanical Comparison of Large versus Small Fragment Fixation for Humeral Shaft Fractures

被引:13
作者
Patel, Ravi [1 ]
Neu, Corey P. [2 ]
Curtiss, Shane
Fyhrie, David P.
Yoo, Brad [1 ]
机构
[1] Univ Calif Davis, Davis Med Ctr, Dept Orthopaed, Sacramento, CA 95817 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
humerus fracture; internal fixation; weightbearing; INTERNAL-FIXATION; PLATE FIXATION; BONE; STABILITY; SCREWS; STIFFNESS; STRENGTH; NUMBER;
D O I
10.1097/BOT.0b013e3181df968c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study evaluated the failure properties of length unstable humerii secured with small or large fragment plates. Methods: Two nonlocking plate constructs were examined, a nine-hole 4.5-mm limited contact dynamic compression plate (large fragment group) and a 12-hole 3.5-mm limited contact dynamic compression plate (small fragment group), both on composite humerii with a 1-cm defect to simulate comminution (n = 12 for each group). Each plate construct had similar working lengths and number of fixation points. Mechanical testing was first randomized for stiffness measurements in axial and torsional loads. All constructs were then tested in cyclic axial loads to failure. Results: For axial testing, the large fragment group had a mean stiffness of 1020 +/- 195 N/mm compared with 268 +/- 67 N/mm in the small fragment group (P < 0.0001). For torsional testing, the large fragment group had a mean stiffness of 1.5 +/- 0.05 Nm/degree compared with 0.9 +/- 0.04 Nm/degree in the small fragment group (P < 0.0001). Plastic deformation in the large fragment and small fragment groups were 0.09 +/- 0.07 mm and 0.20 +/- 0.24 mm, respectively (P = 0.1) assessed during cyclic testing up to 300 N. The postcyclic yield force in the large fragment group was 227 +/- 30 N and in the small fragment group was 153 +/- 5 N (P < 0.0001). The ultimate load in the large fragment and small fragment groups were 800 +/- 87 N and 307 +/- 15 N, respectively. Conclusion: The results corroborate anticipated plate mechanical behavior with plate stiffness increasing as both plate width and thickness increase. The calculated yield force data suggest that both small and large fragment constructs would experience plastic deformation during bilateral crutch ambulation in a patient weighing 50 kg or more. The large fragment construct is not expected to catastrophically fail when subjected to loads in a patient 90 kg or less. The small fragment construct is predicted to catastrophically fail in patients weighing 70 kg or more.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 30 条
  • [1] Augat P, 1996, CLIN ORTHOP RELAT R, P194
  • [2] THE RESULTS OF PLATING HUMERAL SHAFT FRACTURES IN PATIENTS WITH MULTIPLE INJURIES - THE SUNNYBROOK EXPERIENCE
    BELL, MJ
    BEAUCHAMP, CG
    KELLAM, JK
    MCMURTRY, RY
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02): : 293 - 296
  • [3] BERGMANN G, 1978, Z ORTHOP GRENZGEB, V116, P106
  • [4] BRUMBACK R, 1992, J BONE JOINT SURG AM, V68, P960
  • [5] Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates
    Chapman, JR
    Henley, MB
    Agel, J
    Benca, PJ
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (03) : 162 - 166
  • [6] Fixation stability of comminuted humeral shaft fractures: Locked intramedullary nailing versus plate fixation
    Chen, AL
    Joseph, TN
    Wolinksy, PR
    Tejwani, NC
    Kummer, FJ
    Egol, KA
    Koval, KJ
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (04): : 733 - 737
  • [7] Dabezies E J, 1992, J Orthop Trauma, V6, P10
  • [8] Structural properties of a novel design of composite analogue humeri models
    Dunlap, James T.
    Chong, Alexander C. M.
    Lucas, George L.
    Cooke, Francis W.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (11) : 1922 - 1926
  • [9] The influence of screw omission on construction stiffness and bone surface strain in the application of bone plates to cadaveric bone
    Field, JR
    Törnkvist, H
    Hearn, TC
    Sumner-Smith, G
    Woodside, TD
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (09): : 591 - 598
  • [10] INTERNAL-FIXATION OF FRACTURES AND NON-UNIONS OF THE HUMERAL SHAFT - INDICATIONS AND RESULTS IN A MULTI-CENTER STUDY
    FOSTER, RJ
    DIXON, GL
    BACH, AW
    APPLEYARD, RW
    GREEN, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (06) : 857 - 864