Dosimetry is a widespread material science field dealing with detection and quantification of ionizing radiation using electronic processes in materials. One of the main aspects that determines the performance of dosimeters is the type of defects the material contains. Crystalline lattice imperfections are formed around impurity ions, which may have a smaller or larger size, or different oxidation states compared to host ions. In this study, we show what effects Cr impurities have on the luminescent properties of alumina. Porous Al2O3:Cr microceramics synthesized using the sol-gel method showed a higher thermoluminescence response than a single crystal ruby. We have found that Cr2O3 concentration of 0.2 wt% was optimal; it yielded the highest X-ray luminescence and thermostimulated luminescence readout of all studied additive concentrations added to alumina during synthesis. Our results show that Cr doped alumina could potentially be used as a promising new material for dosimetry of ionizing radiation.
引用
收藏
页码:525 / 535
页数:11
相关论文
共 21 条
[1]  
AKSELROD MS, 1990, RADIAT PROT DOSIM, V32, P15
[2]   A radiation dosimetry method using pulsed optically stimulated luminescence [J].
Akselrod, MS ;
McKeever, SWS .
RADIATION PROTECTION DOSIMETRY, 1999, 81 (03) :167-176
[3]   Photoluminescence and atomic force microscopic studies on pre- and post-irradiated ruby with Ni6+ ion [J].
Bhardwaj, DM ;
Jain, DC ;
Rao, KVR ;
Kumar, R ;
Singh, F ;
Gupta, RP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 222 (3-4) :533-537
[4]   EFFECTS OF LOW-DOSES AND LOW-DOSE RATES OF EXTERNAL IONIZING-RADIATION - CANCER MORTALITY AMONG NUCLEAR INDUSTRY WORKERS IN 3 COUNTRIES [J].
CARDIS, E ;
GILBERT, ES ;
CARPENTER, L ;
HOWE, G ;
KATO, I ;
ARMSTRONG, BK ;
BERAL, V ;
COWPER, G ;
DOUGLAS, A ;
FIX, J ;
FRY, SA ;
KALDOR, J ;
LAVE, C ;
SALMON, L ;
SMITH, PG ;
VOELZ, GL ;
WIGGS, LD .
RADIATION RESEARCH, 1995, 142 (02) :117-132
[5]   Alumina: discriminative analysis using 3D correlation of solid-state NMR parameters [J].
Chandran, C. Vinod ;
Kirschhock, Christine E. A. ;
Radhakrishnan, Sambhu ;
Taulelle, Francis ;
Martens, Johan A. ;
Breynaert, Eric .
CHEMICAL SOCIETY REVIEWS, 2019, 48 (01) :134-156
[6]   Mullite fabrication from natural kaolin and aluminium slag [J].
Chargui, Fouzia ;
Hamidouche, Mohamed ;
Belhouchet, Hocine ;
Jorand, Yves ;
Doufnoune, Rachida ;
Fantozzi, Gilbert .
BOLETIN DE LA SOCIEDAD ESPANOLA DE CERAMICA Y VIDRIO, 2018, 57 (04) :169-177
[7]   Production of alpha-alumina nanoparticles using aquatic humic substances [J].
Cunha, Graziele da Costa ;
Cruz Romao, Luciane Pimenta ;
Macedo, Zelia Soares .
POWDER TECHNOLOGY, 2014, 254 :344-351
[8]  
Davis K., 2010, Sch. Dr. Stud. Eur. Union J, P109
[9]   An automated fitting procedure and software for dose-response curves with multiphasic features [J].
Di Veroli, Giovanni Y. ;
Fornari, Chiara ;
Goldlust, Ian ;
Mills, Graham ;
Koh, Siang Boon ;
Bramhall, Jo L. ;
Richards, Frances M. ;
Jodrell, Duncan I. .
SCIENTIFIC REPORTS, 2015, 5
[10]   DNA Repair After Exposure to Ionizing Radiation Is Not Error-Free [J].
Duncan, James R. ;
Lieber, Michael R. ;
Adachi, Noritaka ;
Wahl, Richard L. .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (02) :348-348