Tricolor dual sensor for ratiometrically analyzing potassium ions and dissolved oxygen

被引:11
作者
Liu, Hongtian [1 ,2 ]
Ning, Juewei [1 ,2 ]
Song, Guangjie [1 ]
Sun, Xiangzhong [1 ]
Su, Fengyu [3 ]
Li, Pengfei [4 ]
Tian, Yanqing [1 ]
机构
[1] Southern Univ Sci & Technol, Dept Mat Sci & Engn, Shenzhen 518055, Peoples R China
[2] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
[3] Southern Univ Sci & Technol, Acad Adv Interdisciplinary Studies, Shenzhen 518055, Peoples R China
[4] Southern Univ Sci & Technol, Coll Sci, Dept Chem, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual sensor; Oxygen scissor; Potassium ion sensor; Fluorescence; Ratiometric sensor; FLUORESCENT SENSOR; NANOSENSORS; SENSITIVITY; MECHANISMS; MEMBRANE; INDEX; LIFE;
D O I
10.1016/j.saa.2020.118155
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A potassium ion-oxygen (K+-O-2) dual fluorescent sensing film was developed. The film contains three probes, which are K+ probe (KS), O-2 probe (OS), and reference probe (RP) in a polymer film composed of poly(ethylene glycol) methyl ether methacrylate (PEGMA), poly(ethylene glycol) dimethacrylate (PEGDMA) and methacrylic acid (MAA). The RP showed blue emission, the KS exhibited green emission, and the OS showed red emission. The emission peaks of three probes do not interfere with each other, which enable the sensing film to be used for ratiometrically and quantitatively detecting the concentrations of K+ and dissolved oxygen (DO). The sensing films showed high sensitivity and selectivity to potassium ions over other metal ions and also good sensitivity for DO from deoxygenated to oxygenated conditions. The sensing film was demonstrated to be capable of analyzing K+ and DO concentrations with experimental errors smaller than +/- 8.5% in aqueous solutions, showing the potential applications of the sensing films. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 46 条
  • [1] Al-Rawi SM, 2005, RAF J SCI, V16, P56
  • [2] A fluorogenic BODIPY molecular rotor as an apoptosis marker
    Ashokkumar, Pichandi
    Ashoka, Anila Hoskere
    Collot, Mayeul
    Das, Amitava
    Klymchenko, Andrey S.
    [J]. CHEMICAL COMMUNICATIONS, 2019, 55 (48) : 6902 - 6905
  • [3] Palladium-Mediated Synthesis of a Near-Infrared Fluorescent K+ Sensor
    Bandara, H. M. Dhamrnika
    Hua, Zhengmao
    Zhang, Mei
    Pauff, Steven M.
    Miller, Stephen C.
    Davie, Elizabeth A. Colby
    Kobertz, William R.
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 2017, 82 (15) : 8199 - 8205
  • [4] Boutilier RG, 2001, J EXP BIOL, V204, P3171
  • [5] Experimental investigation of the effect of polymer matrices on polymer fibre optic oxygen sensors and their time response characteristics using a vacuum testing chamber and a liquid flow apparatus
    Chen, Rongsheng
    Formenti, Federico
    McPeak, Hanne
    Obeid, Andrew N.
    Hahn, Clive
    Farmery, Andrew
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 531 - 535
  • [6] COUTANT CC, 1985, T AM FISH SOC, V114, P31, DOI 10.1577/1548-8659(1985)114<31:SBTADO>2.0.CO
  • [7] 2
  • [8] MINIMAL DISSOLVED-OXYGEN REQUIREMENTS OF AQUATIC LIFE WITH EMPHASIS ON CANADIAN SPECIES - REVIEW
    DAVIS, JC
    [J]. JOURNAL OF THE FISHERIES RESEARCH BOARD OF CANADA, 1975, 32 (12): : 2295 - 2332
  • [9] Tricolor core/shell polymeric ratiometric nanosensors for intracellular glucose and oxygen dual sensing
    Deng, Mengyu
    Qiao, Yuan
    Liu, Chang
    Wang, Zijin
    Shi, Jiayan
    Pan, Tingting
    Mao, Yongyun
    Mei, Zhipeng
    Huang, Fei
    Tian, Yanqing
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 437 - 444
  • [10] SELECTRODE - UNIVERSAL ION-SELECTIVE ELECTRODE .7. VALINOMYCIN-BASED POTASSIUM ELECTRODE WITH NONPOROUS POLYMER MEMBRANE AND SOLID-STATE INNER REFERENCE SYSTEM
    FIEDLER, U
    RUZICKA, J
    [J]. ANALYTICA CHIMICA ACTA, 1973, 67 (01) : 179 - 193