The Carbomedics aortic heart valve prosthesis: A review

被引:0
作者
Aagaard, J [1 ]
机构
[1] Odense Univ Hosp, Dept Cardiothorac & Vasc Surg, DK-5000 Odense, Denmark
关键词
aortic valve; heart valve prosthesis; implantation methods; anticoagulants; heart valve prosthesis implantation; adverse effects;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Carbomedics bileaflet mechanical prosthesis was introduced in 1986 and until now more than 500 000 valves have been implanted. The aim of this study was to review the papers published on the Carbomedics aortic heart valve prosthesis. The Carbomedics prosthesis has a solid pyrolite carbon housing and flat leaflets of pyrolite carbon coated graphite that is impregnated with tungsten. The pyrolite carbon housing is reinforced by an outer stiffening ring composed of titanium which virtually eliminates the risk of leaflet escape. The design further enables valve rotation after implantation. The standard aortic valve prosthesis has the sewing cuff located at the outflow level of the valve cylinder. A high-performance valve the Carbomedics TopHat valve for supraannular implantation, is a standard aortic valve prosthesis where the sewing cuff has been transferred to the inflow level of the valve cylinder. A 2 size increase in valve size can he achieved by using the TopHat valve which is very important in patient-prosthesis mismatch. With the recommended international normalised ratio (INR) level for the Carbomedics aortic heart valve prosthesis the rate of embolic and bleeding events are low. Thrombosis of a Carbomedics aortic heart valve prosthesis is rarely seen and is the result of inappropriate anticoagulation without pannus formation. The incidence of prosthetic endocarditis is very low and this is also the case for noninfectious paravalvular leakage necessitating reoperation. Intrinsic dysfunction and/or structural failure has never been reported. The total absence of intrinsic dysfunction and structural failure of the Carbomedics aortic valve prosthesis is a great advantage. Further the complication rate is very low. The TopHat, the supraannular version of this prosthesis, is a perfect solution in patient-prosthesis mismatch.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 24 条
  • [1] Aagaard J, 2003, J HEART VALVE DIS, V12, P81
  • [2] Aagaard J, 2001, J HEART VALVE DIS, V10, P177
  • [3] Aagaard J, 1995, J Heart Valve Dis, V4, P628
  • [4] [Anonymous], ASIAN CARDIOVASC THO
  • [5] 10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS
    AROM, KV
    NICOLOFF, DM
    KERSTEN, TE
    NORTHRUP, WF
    LINDSAY, WG
    EMERY, RW
    [J]. ANNALS OF THORACIC SURGERY, 1989, 47 (06) : 831 - 837
  • [6] The CarboMedics "Top-Hat" supraannular prosthesis
    Bernal, JM
    Martin-Duran, R
    Rabasa, JM
    Revuelta, JM
    [J]. ANNALS OF THORACIC SURGERY, 1999, 67 (05) : 1299 - 1303
  • [7] The CarboMedics valve: Experience with 1,049 implants
    Bernal, JM
    Rabasa, JM
    Gutierrez-Garcia, F
    Morales, C
    Nistal, JF
    Revuelta, JM
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (01) : 137 - 143
  • [8] Binuani P, 2000, J HEART VALVE DIS, V9, P693
  • [9] ECHOCARDIOGRAPHIC DESCRIPTION OF THE CARBOMEDICS BILEAFLET PROSTHETIC HEART-VALVE
    CHAMBERS, J
    CROSS, J
    DEVERALL, P
    SOWTON, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 398 - 405
  • [10] A STUDY OF THE STABILITY OF ORIENTATION IN THE CARBOMEDICS BILEAFLET HEART-VALVE PROSTHESIS
    CHAMBERS, JB
    DEVERALL, PB
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (08) : 442 - 445