Preparation techniques for micron-sized particulate samples in X-ray microtomography

被引:13
|
作者
Ditscherlein, Ralf [1 ]
Leissner, Thomas [1 ]
Peuker, Urs A. [1 ]
机构
[1] Tech Univ Bergakad Freiberg, Inst Mech Proc Engn & Mineral Proc, Agricolastr 1, D-09599 Freiberg, Germany
关键词
Particle characterization; Sample preparation; X-ray microtomography; XMT; XRM; GRAIN-BOUNDARY FRACTURE; MULTIPHASE PARTICLES; QUANTITATIVE-ANALYSIS; 3D CHARACTERIZATION; TOOL; BREAKAGE;
D O I
10.1016/j.powtec.2019.06.001
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
New application fields of particle technology, e.g. coatings, pharmaceuticals or electronic components require more and more highly defined particles in the lower micrometer range. In this case the particle size distribution (PSD) is no longer sufficient to define the specifications alone. The particle system has to be described by further distributed properties, which are for instance particle shape or particle composition. Tomographic particle characterization is one key methodology to provide the data, required to quantify these specifications. The tomogram of a representative particle sample contains information on the size and shape of each individual particle. The data of X-ray absorption furthermore gives hints about the material properties and structure of intergrown or composite structures. One central challenge in the tomography of a particle sample is the segmentation of the image data. When the particles in the sample are too close to each other, the algorithm is not able to separate individuals. On the other hand, oversegmentation can occur, when a particle is separated into two or more individuals during the image processing. Therefore, the physical sample preparation, which keeps the particles at a defined distance, strongly facilitates any automated segmentation. The established techniques known from SEM, TEM or automated mineralogy (MLA) cannot be transferred to X-ray microtomography (XMT), because they only have to provide a representative 2D-measuring plane. The 3D-sample preparation introduced here is able to provide a homogeneous particle sample immobilized within a matrix material with low X-ray absorption. In the sample, all particles have a minimum distance which amounts to more than a defined minimum multitude of the voxel size. The carrier matrix is a wax structure, that is shock frozen within a small polymeric tube with inner diameter from 0.5 mm to 2 mm. This corresponds to the requested sample size for the tomographic measurements (X-ray microscopy system Zeiss VERSA 510), which is 1024 times voxel size (approximate to 0.5 mu m to 2 mu m), allowing multi-dimensional characterization of particles from 5 mu m to 50 mu m in size and shape. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:989 / 997
页数:9
相关论文
共 50 条
  • [41] An X-ray microtomography study on the mineral concentration of carious dentine removed during cavity preparation in deciduous molars
    Willmott, N. S.
    Wong, F. S. L.
    Davis, G. R.
    CARIES RESEARCH, 2007, 41 (02) : 129 - 134
  • [42] Study by X-ray microtomography of the horizontal vibration effects on sand densification
    Olmos, L.
    Chaix, J. -M.
    Nadler, S.
    Bonnefoy, O.
    Gelet, J. -L.
    Thomas, G.
    GRANULAR MATTER, 2016, 18 (03)
  • [43] In vivo assessment of emphysema in mice by high resolution X-ray microtomography
    Postnov, AA
    Meurrens, K
    Weiler, H
    Van Dyck, D
    Hu, X
    Terpstra, P
    De Clerck, NM
    JOURNAL OF MICROSCOPY, 2005, 220 : 70 - 75
  • [44] Shear cracking in an Al powder compact studied by X-ray microtomography
    McDonald, S. A.
    Motazedian, F.
    Cocks, A. C. F.
    Withers, P. J.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2009, 508 (1-2): : 64 - 70
  • [45] The contribution of synchrotron X-ray computed microtomography to understanding volcanic processes
    Polacci, Margherita
    Mancini, Lucia
    Baker, Don R.
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 215 - 221
  • [46] Microstructural Characterization of Siltstone and Sandstone Pore Space by X-Ray Microtomography
    Fernandes, J. S.
    Appoloni, C. R.
    Fernandes, C. P.
    SOILS AND ROCKS, 2019, 42 (03): : 281 - 288
  • [47] X-ray microtomography for imaging of developing spiders inside egg cocoons
    Babczynska, Agnieszka
    Binkowski, Marcin
    Bednarek, Agata
    Ogierman, Sylwia
    Cibura, Dorota
    Migula, Pawel
    Wilczek, Grazyna
    Szulinska, Elzbieta
    ARTHROPOD STRUCTURE & DEVELOPMENT, 2014, 43 (06) : 595 - 603
  • [48] Acidic demineralization of apatites studied by scanning X-ray microradiography and microtomography
    Elliott, JC
    Bollet-Quivogne, FRG
    Anderson, P
    Dowker, SEP
    Wilson, RM
    Davis, GR
    MINERALOGICAL MAGAZINE, 2005, 69 (05) : 643 - 652
  • [49] Validation of Terahertz Coating Thickness Measurements Using X-ray Microtomography
    Russe, Isabelle-Sophie
    Brock, Daniela
    Knop, Klaus
    Kleinebudde, Peter
    Zeitler, J. Axel
    MOLECULAR PHARMACEUTICS, 2012, 9 (12) : 3551 - 3559
  • [50] Application of X-ray microtomography to quality assessment of fibre cement boards
    Schabowicz, Krzysztof
    Ranachowski, Zbigniew
    Jozwiak-Niedzwiedzka, Dania
    Radzik, Lukasz
    Kudela, Stanislav, Jr.
    Dvorak, Tomas
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 110 : 182 - 188