Optimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments

被引:129
作者
Dimigen, Olaf [1 ]
机构
[1] Humboldt Univ, Unter Linden 6, D-10099 Berlin, Germany
关键词
EEG; Eye tracking; Eye artifact correction; Independent component analysis (ICA); Fixation-related potentials (FRP); Beta and gamma oscillations; FIXATION-RELATED POTENTIALS; INDEPENDENT COMPONENT ANALYSIS; EVENT-RELATED POTENTIALS; EYE-MOVEMENT; BRAIN POTENTIALS; WORD RECOGNITION; SUPPRESSION; VOLUNTARY; IDENTIFICATION; CONTAMINATION;
D O I
10.1016/j.neuroimage.2019.116117
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Combining EEG with eye-tracking is a promising approach to study neural correlates of natural vision, but the resulting recordings are also heavily contaminated by activity of the eye balls, eye lids, and extraocular muscles. While Independent Component Analysis (ICA) is commonly used to suppress these ocular artifacts, its performance under free viewing conditions has not been systematically evaluated and many published reports contain residual artifacts. Here I evaluated and optimized ICA-based correction for two tasks with unconstrained eye movements: visual search in images and sentence reading. In a first step, four parameters of the ICA pipeline were varied orthogonally: the (1) high-pass and (2) low-pass filter applied to the training data, (3) the proportion of training data containing myogenic saccadic spike potentials (SP), and (4) the threshold for eye tracker-based component rejection. In a second step, the eye-tracker was used to objectively quantify the correction quality of each ICA solution, both in terms of undercorrection (residual artifacts) and overcorrection (removal of neurogenic activity). As a benchmark, results were compared to those obtained with an alternative spatial filter, Multiple Source Eye Correction (MSEC). With commonly used settings, Infomax ICA not only left artifacts in the data, but also distorted neurogenic activity during eye movement-free intervals. However, correction results could be strongly improved by training the ICA on optimally filtered data in which SPs were massively overweighted. With optimized procedures, ICA removed virtually all artifacts, including the SP and its associated spectral broadband artifact from both viewing paradigms, with little distortion of neural activity. It also outperformed MSEC in terms of SP correction. Matlab code is provided.
引用
收藏
页数:17
相关论文
共 118 条
[1]   Direction and viewing area-sensitive influence of EOG artifacts revealed in the EEG topographic pattern analysis [J].
Ai, Guangyi ;
Sato, Naoyuki ;
Singh, Balbir ;
Wagatsuma, Hiroaki .
COGNITIVE NEURODYNAMICS, 2016, 10 (04) :301-314
[2]  
ARMINGTON JC, 1978, VISUAL PSYCHOPHYSICS, P363
[3]   Applying dimension reduction to EEG data by Principal Component Analysis reduces the quality of its subsequent Independent Component decomposition [J].
Artoni, Fiorenzo ;
Delorme, Arnaud ;
Makeig, Scott .
NEUROIMAGE, 2018, 175 :176-187
[4]  
BACCINO T, 2011, HDB EYE MOVEMENTS, P857, DOI DOI 10.1093/OXFORDHB/9780199539789.013.0047
[5]  
Bækgaard P, 2014, INT WORK COGNIT INFO
[6]   THE HUMAN PRE-SACCADIC SPIKE POTENTIAL - INFLUENCES OF A VISUAL TARGET, SACCADE DIRECTION, ELECTRODE LATERALITY AND INSTRUCTIONS TO PERFORM SACCADES [J].
BALABAN, CD ;
WEINSTEIN, JM .
BRAIN RESEARCH, 1985, 347 (01) :49-57
[7]  
BARRY W, 1965, AEROSPACE MED, V36, P855
[8]   PREPARATION POTENTIAL, PREMOTOR POSITIVITY AND OTHER CEREBRAL POTENTIALS DURING SACCADIC OCULOMOTOR ACTIVITY [J].
BECKER, W ;
IWASE, K ;
HOEHNE, O ;
KORNHUBER, HH .
VISION RESEARCH, 1972, 12 (03) :421-+
[9]   AN INFORMATION MAXIMIZATION APPROACH TO BLIND SEPARATION AND BLIND DECONVOLUTION [J].
BELL, AJ ;
SEJNOWSKI, TJ .
NEURAL COMPUTATION, 1995, 7 (06) :1129-1159
[10]   Early electrophysiological indicators for predictive processing in audition: A review [J].
Bendixen, Alexandra ;
SanMiguel, Iria ;
Schroeger, Erich .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 83 (02) :120-131