This report introduces a bleaching-independent temperature measurement method based on the analysis of the fluorescence emitted during the melting of DNA molecules with the SYBR-Green I intercalator, in a microvolume where the strong non-linearity of the signal is used to eliminate the photobleaching effect as well as to determine the heat transfer rate between a heater and the sample and the temperature non-uniformity within the sample.
引用
收藏
页码:2818 / 2821
页数:4
相关论文
共 15 条
[1]   DNA sequencing by denaturation: Principle and thermodynamic simulations [J].
Chen, Ying-Ja ;
Huang, Xiaohua .
ANALYTICAL BIOCHEMISTRY, 2009, 384 (01) :170-179
[2]   A microfluidic platform using molecular beacon-based temperature calibration for thermal dehybridization of surface-bound DNA [J].
Dodge, A ;
Turcatti, G ;
Lawrence, I ;
de Rooij, NF ;
Verpoorte, E .
ANALYTICAL CHEMISTRY, 2004, 76 (06) :1778-1787
[3]   Dual-pump coherent anti-Stokes Raman scattering for simultaneous pressure/temperature measurement [J].
Foglesong, RE ;
Green, SM ;
Lucht, RP ;
Dutton, JC .
AIAA JOURNAL, 1998, 36 (02) :234-240
[4]  
LU W, 2001, J THERM SCI, V10, P372
[5]   Disposable real-time microPCR device: lab-on-a-chip at a low cost [J].
Neuzil, Pavel ;
Pipper, Juergen ;
Hsieh, Tseng Ming .
MOLECULAR BIOSYSTEMS, 2006, 2 (6-7) :292-298
[6]   The use of differential scanning fluorimetry to detect ligand interactions that promote protein stability [J].
Niesen, Frank H. ;
Berglund, Helena ;
Vedadi, Masoud .
NATURE PROTOCOLS, 2007, 2 (09) :2212-2221
[7]   Product differentiation by analysis of DNA melting curves during the polymerase chain reaction [J].
Ririe, KM ;
Rasmussen, RP ;
Wittwer, CT .
ANALYTICAL BIOCHEMISTRY, 1997, 245 (02) :154-160
[8]  
*ROCH DIAGN INC, 2005, LIGHTC 480
[9]   Infrared temperature control system for a completely noncontact polymerase chain reaction in microfluidic chips [J].
Roper, Michael G. ;
Easley, Christopher J. ;
Legendre, Lindsay A. ;
Humphrey, Joseph A. C. ;
Landers, James P. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1294-1300
[10]   Temperature measurement in microfluidic systems using a temperature-dependent fluorescent dye [J].
Ross, D ;
Gaitan, M ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4117-4123