Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization

被引:32
作者
Sun, Yue [1 ]
Yuan, Jing [1 ]
Qiu, Wu [1 ]
Rajchl, Martin [1 ]
Romagnoli, Cesare [2 ]
Fenster, Aaron [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
Convex optimization; magnetic resonance to transrectal ultrasound (MR-TRUS) prostate registration; modality independent neighborhood descriptor (MIND) similarity measurement; nonrigid image registration; GUIDED PROSTATE BIOPSY; IMAGE REGISTRATION; TRANSRECTAL ULTRASONOGRAPHY; RADICAL PROSTATECTOMY; CANCER; FLOW; SEGMENTATION; ACCURACY; MODEL;
D O I
10.1109/TMI.2014.2375207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, we proposed an efficient nonrigid magnetic resonance (MR) to transrectal ultrasound (TRUS) deformable registration method in order to improve the accuracy of targeting suspicious regions during a three dimensional (3-D) TRUS guided prostate biopsy. The proposed deformable registration approach employs the multi-channel modality independent neighborhood descriptor (MIND) as the local similarity feature across the two modalities of MR and TRUS, and a novel and efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations and align the two MIND descriptors. The registration accuracy was evaluated using 20 patient images by calculating the TRE using manually identified corresponding intrinsic fiducials in the whole gland and peripheral zone. Additional performance metrics [Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD)] were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. The results obtained in terms of DSC showed an average of 80.8 +/- 7.8% for the apex of the prostate, 92.0 +/- 3.4% for the mid-gland, 81.7 +/- 6.4% for the base and 85.7 +/- 4.7% for the whole gland. The surface distance calculations showed an overall average of 1.84 +/- 0.52 mm for MAD and 6.90 +/- 2.07 mm for MAXD.
引用
收藏
页码:1085 / 1095
页数:11
相关论文
共 50 条
  • [41] Die filling optimization using three-dimensional discrete element modeling
    Bierwisch, C.
    Kraft, T.
    Riedel, H.
    Moseler, M.
    POWDER TECHNOLOGY, 2009, 196 (02) : 169 - 179
  • [42] Protocol Optimization of Three-Dimensional Spiral CT of Craniofacial Bones
    Volz, G.
    Schwaderer, E.
    Dammann, F.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (03): : 244 - 250
  • [43] Modeling and Registration for Electrophysiology Procedures Based on Three-Dimensional Imaging
    Rhode K.
    Sermesant M.
    Current Cardiovascular Imaging Reports, 2011, 4 (2) : 116 - 126
  • [44] Validation of nonrigid image registration using finite-element methods: Application to breast MR images
    Schnabel, JA
    Tanner, C
    Castellano-Smith, AD
    Degenhard, A
    Leach, MO
    Hose, DR
    Hill, DLG
    Hawkes, DJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (02) : 238 - 247
  • [45] Registration of three-dimensional magnetic resonance and radionuclide skeletal images
    Wong, TZ
    Connolly, LP
    Treves, ST
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (11) : 859 - 863
  • [46] Multiscale segmentation of three-dimensional MR brain images
    Niessen, WJ
    Vincken, KL
    Weickert, J
    Romeny, BMT
    Viergever, MA
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1999, 31 (2-3) : 185 - 202
  • [47] Three-dimensional registration of tomography data for quantification in biomaterials science
    Mueller, Bert
    Deyhle, Hans
    Lang, Sabrina
    Schulz, Georg
    Bormann, Therese
    Fierz, Fabienne C.
    Hieber, Simone E.
    INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2012, 103 (02) : 242 - 249
  • [48] Three-dimensional registration of prostate images from histology and ultrasound
    Taylor, LS
    Porter, BC
    Nadasdy, G
    Di Sant'Agnese, PA
    Pasternack, D
    Wu, Z
    Baggs, RB
    Rubenst, DJ
    Parker, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02) : 161 - 168
  • [49] Multiscale Approach for Three-Dimensional Conformal Image Registration\ast
    Han, Huan
    Wang, Zhengping
    Zhang, Yimin
    SIAM JOURNAL ON IMAGING SCIENCES, 2022, 15 (03): : 1431 - 1468
  • [50] Automated three-dimensional image registration for longitudinal photoacoustic imaging
    De Santi, Bruno
    Kim, Lucia
    Bulthuis, Rianne F. G.
    Lucka, Felix
    Manohar, Srirang
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29