Inner-ear augmented metal artifact reduction with simulation-based 3D generative adversarial networks

被引:6
作者
Wang, Zihao [1 ,2 ]
Vandersteen, Clair [2 ,3 ]
Demarcy, Thomas [4 ]
Gnansia, Dan [4 ]
Raffaelli, Charles [2 ,5 ]
Guevara, Nicolas [2 ,3 ]
Delingette, Herve [1 ,2 ]
机构
[1] Univ Cote Azur, Inria Sophia Antipolis Mediterranee, 2004 Route Lucioles, F-06902 Valbonne, France
[2] Univ Cote Azur, 28 Ave Valrose, F-06108 Nice, France
[3] Nice Univ Hosp, Head & Neck Univ Inst, 31 Ave Valombrose, F-06100 Nice, France
[4] Oticon Med, 14 Chemin St Bernard Porte, F-06220 Vallauris, France
[5] Nice Univ Hosp, Dept Radiol, 31 Ave Valombrose, F-06100 Nice, France
关键词
Artifact reduction; Deep learning; GAN; ELECTRODE POSITION; CT; COCHLEA; NMAR;
D O I
10.1016/j.compmedimag.2021.101990
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metal Artifacts creates often difficulties for a high quality visual assessment of post-operative imaging in computed tomography (CT). A vast body of methods have been proposed to tackle this issue, but these methods were designed for regular CT scans and their performance is usually insufficient when imaging tiny implants. In the context of post-operative high-resolution CT imaging, we propose a 3D metal artifact reduction algorithm based on a generative adversarial neural network. It is based on the simulation of physically realistic CT metal artifacts created by cochlea implant electrodes on preoperative images. The generated images serve to train a 3D generative adversarial networks for artifacts reduction. The proposed approach was assessed qualitatively and quantitatively on clinical conventional and cone beam CT of cochlear implant postoperative images. These experiments show that the proposed method outperforms other general metal artifact reduction approaches.
引用
收藏
页数:13
相关论文
共 38 条
  • [21] Regularized Three-Dimensional Generative Adversarial Nets for Unsupervised Metal Artifact Reduction in Head and Neck CT Images
    Nakao, Megumi
    Imanishi, Keiho
    Ueda, Nobuhiro
    Imai, Yuichiro
    Kirita, Tadaaki
    Matsuda, Tetsuya
    [J]. IEEE ACCESS, 2020, 8 : 109453 - 109465
  • [22] Metal artifact reduction in dental CT images using polar mathematical morphology
    Naranjo, Valery
    Llorens, Roberto
    Alcaniz, Mariano
    Lopez-Mir, Fernando
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 102 (01) : 64 - 74
  • [23] Clinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
    Noble, Jack H.
    Gifford, Rene H.
    Hedley-Williams, Andrea J.
    Dawant, Benoit M.
    Labadie, Robert F.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2014, 19 (06) : 400 - 411
  • [24] Ourselin S, 2000, LECT NOTES COMPUT SC, V1935, P557
  • [25] Rui X., 2013, 2013 IEEE NUCL SCI S
  • [26] Sanchez I, 2018, BRAIN MRI SUPER RESO
  • [27] Evaluation of cochlear implant electrode position after a modified round window insertion by means of a 64-multislice CT
    Todt, Ingo
    Rademacher, Grit
    Wagner, Jan
    Goepel, Friederike
    Basta, Dietmar
    Haider, Ernst
    Ernst, Arne
    [J]. ACTA OTO-LARYNGOLOGICA, 2009, 129 (09) : 966 - 970
  • [28] CT metal artifact reduction method correcting for beam hardening and missing projections
    Verburg, Joost M.
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) : 2803 - 2818
  • [29] Wang JN, 2020, I S BIOMED IMAGING, P596, DOI 10.1109/ISBI45749.2020.9098707
  • [30] Metal artifact reduction for the segmentation of the intra cochlear anatomy in CT images of the ear with 3D-conditional GANs
    Wang, Jianing
    Noble, Jack H.
    Dawant, Benoit M.
    [J]. MEDICAL IMAGE ANALYSIS, 2019, 58