OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up

被引:44
作者
Kala, Petr [1 ,6 ]
Cervinka, Pavel [2 ]
Jakl, Martin [3 ]
Kanovsky, Jan [1 ,6 ]
Kupec, Andrej [2 ]
Spacek, Radim [2 ]
Kvasnak, Martin [2 ]
Poloczek, Martin [1 ]
Cervinkova, Michaela [2 ,3 ]
Bezerra, Hiram [4 ]
Valenta, Zdenek [5 ]
Attizzani, Guilherme F. [4 ]
Schnell, Audrey [4 ]
Hong, Lu [7 ]
Costa, Marco A. [4 ]
机构
[1] Univ Hosp Brno, Dept Cardiol & Internal Med, Brno, Czech Republic
[2] UJEP Usti Nad Labem, Masaryk Hosp, Krajska Zdravotni As, Dept Cardiol, Socialni Pece 3316-12a, Usti Nad Labem 40113, Czech Republic
[3] Fac Hosp Hradec Kralove, Dept Cardioangiol & Internal Med 1, Hradec Kralove, Czech Republic
[4] Univ Hosp Cleveland, Case Med Ctr, Harrington Heart & Vasc Inst, Cleveland, OH 44106 USA
[5] Czech Acad Sci, Inst Comp Sci, Dept Stat Medelling, Prague, Czech Republic
[6] Masaryk Univ, Med Fac, Brno, Czech Republic
[7] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
Optical coherence tomography; OCT; Primary PCI; ST-segment elevation myocardial infarction; Drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; ELEVATION MYOCARDIAL-INFARCTION; SIROLIMUS-ELUTING STENT; GUIDE DECISION-MAKING; BARE-METAL STENTS; CLINICAL-OUTCOMES; THROMBOSIS; FEASIBILITY; APPOSITION; PREDICTORS;
D O I
10.1016/j.ijcard.2017.10.059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To assess the possible merits of optical coherence tomography (OCT) guidance in primary percutaneous coronary intervention (pPCI). Methods and results: 201 patients with ST-elevation myocardial infarction (STEMI) were enrolled in this study. Patients were randomized either to pPCI alone (angio-guided group, n = 96) or to pPCI with OCT guidance (OCT-guided group, n = 105) and also either to biolimus A9 or to everolimus-eluting stent implantation. All patients were scheduled for nine months of follow-up angiography and OCT study. OCT guidance led to post-pPCI optimization in 29% of cases (59% malapposition and 41% dissections). No complications were found related to the OCT study. OCT analysis at ninemonths showed significantly less in-segment area of stenosis (6% [-11, 19] versus 18% [3, 33]; p = 0.0002) in favor of the OCT-guided group. The rate major adverse cardiovascular events were comparable at nine months in both groups (3% in the OCT group versus 2% in the angio-guided group; p = 0.87). Conclusions: This study demonstrates the safety of OCT guidance during pPCI. The use of OCT optimized stent deployment in 1/3 of patients in this clinical scenario and significantly reduced in-segment area of stenosis at nine months of follow-up. Whether such improvements in OCT endpoints will have a positive impact on late clinical outcomes, they demand both a larger and longer-term follow-up study. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 25 条
  • [1] Mechanisms, Pathophysiology, and Clinical Aspects of Incomplete Stent Apposition
    Attizzani, Guilherme F.
    Capodanno, Davide
    Ohno, Yohei
    Tamburino, Corrado
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) : 1355 - 1367
  • [2] Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Sirbu, Vasile
    Musumeci, Giuseppe
    Lortkipanidze, Nikoloz
    Fujino, Yusuke
    Wang, Wei
    Nakamura, Sunao
    Erglis, Andrej
    Guagliumi, Giulio
    Costa, Marco A.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 228 - 236
  • [3] Three-dimensional imaging of fibrous cap by frequency-domain optical coherence tomography
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Costa, Marco A.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 547 - 549
  • [4] Optical Coherence Tomography-Guided Primary Percutaneous Coronary Intervention in ST-Segment Elevation Myocardial Infarction Patients: A Pilot Study
    Cervinka, Pavel
    Spacek, Radim
    Bystron, Marian
    Kvasnak, Martin
    Kupec, Andrej
    Cervinkova, Michaela
    Kala, Petr
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (04) : 420 - 427
  • [5] Incidence, Predictors, Morphological Characteristics, and Clinical Outcomes of Stent Edge Dissections Detected by Optical Coherence Tomography
    Chamie, Daniel
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Yamamoto, Hirosada
    Kanaya, Tomoaki
    Stefano, Gregory T.
    Fujino, Yusuke
    Mehanna, Emile
    Wang, Wei
    Abdul-Aziz, Ahmad
    Dias, Matthew
    Simon, Daniel I.
    Costa, Marco A.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (08) : 800 - 813
  • [6] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    [J]. CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [7] Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting Stent implantation
    Fujii, K
    Carlier, SG
    Mintz, GS
    Yang, YM
    Moussa, I
    Weisz, G
    Dangas, G
    Mehran, R
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Moses, JW
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 995 - 998
  • [8] Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation
    Im, Eui
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (01) : 88 - 96
  • [9] Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention
    Imola, Fabrizio
    Mallus, Maria Teresa
    Ramazzotti, Vito
    Manzoli, Alessandro
    Pappalardo, Alessandro
    Di Giorgio, Alessandro
    Albertucci, Mario
    Prati, Francesco
    [J]. EUROINTERVENTION, 2010, 6 (05) : 575 - 581
  • [10] Intravascular Ultrasound-Guided Implantation of Drug-Eluting Stents to Improve Outcome A Meta-Analysis
    Jang, Jae-Sik
    Song, Yeo-Jeong
    Kang, Wook
    Jin, Han-Young
    Seo, Jeong-Sook
    Yang, Tae-Hyun
    Kim, Dae-Kyeong
    Cho, Kyoung-Im
    Kim, Bo-Hyun
    Park, Yong Hyun
    Je, Hyung-Gon
    Kim, Dong-Soo
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : E27 - 243