A Review of Research on Large Scale Modern Vertical Axis Wind Turbines at Uppsala University

被引:30
作者
Apelfrojd, Senad [1 ]
Eriksson, Sandra [1 ]
Bernhoff, Hans [1 ]
机构
[1] Uppsala Univ, Div Elect, Box 534, S-75121 Uppsala, Sweden
关键词
wind power; vertical axis wind turbine (VAWT); permanent magnet synchronous generator (PMSG); FAST MULTIPOLE METHODS; SYNCHRONOUS GENERATOR; PM-GENERATOR; DESIGN OPTIMIZATION; CONTROL-SYSTEM; VAWT; SIMULATIONS; TOWER;
D O I
10.3390/en9070570
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a review of over a decade of research on Vertical Axis Wind Turbines (VAWTs) conducted at Uppsala University. The paper presents, among others, an overview of the 200 kW VAWT located in Falkenberg, Sweden, as well as a description of the work done on the 12 kW prototype VAWT in Marsta, Sweden. Several key aspects have been tested and successfully demonstrated at our two experimental research sites. The effort of the VAWT research has been aimed at developing a robust large scale VAWT technology based on an electrical control system with a direct driven energy converter. This approach allows for a simplification where most or all of the control of the turbines can be managed by the electrical converter system, reducing investment cost and need for maintenance. The concept features an H-rotor that is omnidirectional in regards to wind direction, meaning that it can extract energy from all wind directions without the need for a yaw system. The turbine is connected to a direct driven permanent magnet synchronous generator (PMSG), located at ground level, that is specifically developed to control and extract power from the turbine. The research is ongoing and aims for a multi-megawatt VAWT in the near future.
引用
收藏
页数:16
相关论文
共 71 条
  • [1] Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P1, DOI 10.1002/0470012684
  • [2] [Anonymous], 2010, WIND ENERGY EXPLAINE
  • [3] Apelfrojd S., 2013, Journal of Renewable Energy, DOI 10.1155/2013/190573
  • [4] Apelfrojd S., 2012, P EWEA 2012 ANN EV C
  • [5] System Efficiency of a Tap Transformer Based Grid Connection Topology Applied on a Direct Driven Generator for Wind Power
    Apelfrojd, Senad
    Eriksson, Sandra
    [J]. SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] Bulow F., 2010, P EUR WIND EN C EXH
  • [7] No-load core loss prediction of PM generator at low electrical frequency
    Bulow, Fredrik
    Eriksson, Sandra
    Bernhoff, Hans
    [J]. RENEWABLE ENERGY, 2012, 43 : 389 - 392
  • [8] The history and state of the art of variable-speed wind turbine technology
    Carlin, PW
    Laxson, AS
    Muljadi, EB
    [J]. WIND ENERGY, 2003, 6 (02) : 129 - 159
  • [9] Chen JY, 1998, IEEE IND APPLIC SOC, P387, DOI 10.1109/IAS.1998.732331
  • [10] Darrieus G.J.M., 1931, US Patent, Patent No. [1,835,018, 1835018, 1 835 018]