Comparison of Two Software Packages for Perfusion Imaging: Ischemic Core and Penumbra Estimation and Patient Triage in Acute Ischemic Stroke

被引:6
|
作者
Zhou, Xiang [1 ]
Nan, Yashi [2 ]
Ju, Jieyang [3 ]
Zhou, Jingyu [2 ]
Xiao, Huanhui [2 ]
Wang, Silun [2 ]
机构
[1] Tongji Univ, Tongji Hosp, Sch Med, Dept Radiol, 389 Xincun Rd, Shanghai 200065, Peoples R China
[2] YIWEI Med Technol Co Ltd, Room 1001,MAI KE LONG Bldg, Shenzhen 518000, Peoples R China
[3] Nanjing Med Univ, Affiliated Hosp 2, 121 Jiangjiayuan Rd, Nanjing 210011, Peoples R China
基金
中国国家自然科学基金;
关键词
RealNow; RAPID; ischemic core; penumbra; acute ischemic stroke; FINAL INFARCT VOLUME; PREDICT; MAPS; THROMBECTOMY; THRESHOLDS; SELECTION; TIME;
D O I
10.3390/cells11162547
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Purpose: Automated postprocessing packages have been developed for managing acute ischemic stroke (AIS). These packages identify ischemic core and penumbra using either computed tomographic perfusion imaging (CTP) data or magnetic resonance imaging (MRI) data. Measurements of abnormal tissues and treatment decisions derived from different vendors can vary. The purpose of this study is to investigate the agreement of volumetric and decision-making outcomes derived from two software packages. Methods: A total of 594 AIS patients (174 underwent CTP and 420 underwent MRI) were included. Imaging data were accordingly postprocessed by two software packages: RAPID and RealNow. Volumetric outputs were compared between packages by performing intraclass correlation coefficient (ICC), Wilcoxon paired test and Bland-Altman analysis. Concordance of selecting patients eligible for mechanical thrombectomy (MT) was assessed based on neuroimaging criteria proposed in DEFUSE3. Results: In the group with CTP data, mean ischemic core volume (ICV)/penumbral volume (PV) was 14.9/81.1 mL via RAPID and 12.6/83.2 mL via RealNow. Meanwhile, in the MRI group, mean ICV/PV were 52.4/68.4 mL and 48.9/61.6 mL via RAPID and RealNow, respectively. Reliability, which was measured by ICC of ICV and PV in CTP and MRI groups, ranged from 0.87 to 0.99. The bias remained small between measurements (CTP ICV: 0.89 mL, CTP PV: -2 mL, MRI ICV: 3.5 mL and MRI PV: 6.8 mL). In comparison with CTP ICV with follow-up DWI, the ICC was 0.92 and 0.94 for RAPID and Realnow, respectively. The bias remained small between CTP ICV and follow-up DWI measurements (Rapid: -4.65 mL, RealNow: -3.65 mL). Wilcoxon paired test showed no significant difference between measurements. The results of patient triage were concordant in 159/174 cases (91%, ICC: 0.90) for CTP and 400/420 cases (95%, ICC: 0.93) for MRI. Conclusion: The CTP ICV derived from RealNow was more accurate than RAPID. The similarity in volumetric measurement between packages did not necessarily relate to equivalent patient triage. In this study, RealNow showed excellent agreement with RAPID in measuring ICV and PV as well as patient triage.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world
    Cai, Heng
    Fan, Shengyu
    Bian, Yueyan
    Yang, Qi
    Long, Zhenhai
    Chen, Liangyu
    Tang, Wei
    Zhang, Nan
    Zhen, Yongyu
    Li, Zhiqing
    NEURORADIOLOGY, 2022, 64 (01) : 161 - 169
  • [42] Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools
    Hoelter, Philip
    Muehlen, Iris
    Goelitz, Philipp
    Beuscher, Vanessa
    Schwab, Stefan
    Doerfler, Arnd
    NEURORADIOLOGY, 2020, 62 (10) : 1231 - 1238
  • [43] A Comparison of CT Perfusion Output of RapidAI and Viz.ai Software in the Evaluation of Acute Ischemic Stroke
    Bushnaq, Saif
    Hassan, Ameer E.
    Delora, Adam
    Kerro, Ali
    Datta, Anita
    Ezzeldin, Rime
    Ali, Zuhair
    Anwoju, Tunmi
    Nejad, Layla
    Silva, Rene
    Abualnadi, Yazan Diya
    Khalil, Zorain Mustafa
    Ezzeldin, Mohamad
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (07) : 863 - 870
  • [44] Comparison of Susceptibility-Weighted Imaging and Perfusion-Weighted Imaging in the Estimation of the Amount of Reversible Ischemic Tissue (Penumbra)
    Meisam Sheikhbabaei
    Farideh Gharekhanloo
    Mojtaba Khazaei
    Azar Pirdehghan
    SN Comprehensive Clinical Medicine, 5 (1)
  • [45] Automated CT perfusion imaging for acute ischemic stroke Pearls and pitfalls for real-world use
    Vagal, Achala
    Wintermark, Max
    Nael, Kambiz
    Bivard, Andrew
    Parsons, Mark
    Grossman, Aaron W.
    Khatri, Pooja
    NEUROLOGY, 2019, 93 (20) : 888 - 898
  • [46] Clinical application of perfusion and diffusion MR imaging in acute ischemic stroke
    Ueda, T
    Yuh, WTC
    Taoka, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (03) : 305 - 309
  • [47] Automated CT Perfusion Detection of the Acute Infarct Core in Ischemic Stroke: A Systematic Review and Meta-Analysis
    Lim, Nicholas E.
    Chia, Benjamin
    Bulsara, Max K.
    Parsons, Mark
    Hankey, Graeme J.
    Bivard, Andrew
    CEREBROVASCULAR DISEASES, 2023, 52 (01) : 97 - 109
  • [48] CT Perfusion is All we Need: 4D CNN Segmentation of Penumbra and Core in Patients With Suspected Acute Ischemic Stroke
    Tomasetti, Luca
    Engan, Kjersti
    Hollesli, Liv Jorunn
    Kurz, Kathinka Dahli
    Khanmohammadi, Mahdieh
    IEEE ACCESS, 2023, 11 : 138936 - 138953
  • [49] Comparison of Automated CT Perfusion Softwares in Evaluation of Acute Ischemic Stroke
    Xiong, Yunyun
    Huang, Chiwen C.
    Fisher, Marc
    Hackney, David B.
    Bhadelia, Rafeeque A.
    Selim, Magdy H.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2019, 28 (12)
  • [50] Optimal thresholds for ischemic penumbra predicted by computed tomography perfusion in patients with acute ischemic stroke treated with mechanical thrombectomy
    Kameda, Katsuharu
    Uno, Junji
    Otsuji, Ryosuke
    Ren, Nice
    Nagaoka, Shintaro
    Maeda, Kazushi
    Ikai, Yoshiaki
    Gi, Hidefuku
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (03) : 279 - 284