Comparison of Two Software Packages for Perfusion Imaging: Ischemic Core and Penumbra Estimation and Patient Triage in Acute Ischemic Stroke

被引:6
|
作者
Zhou, Xiang [1 ]
Nan, Yashi [2 ]
Ju, Jieyang [3 ]
Zhou, Jingyu [2 ]
Xiao, Huanhui [2 ]
Wang, Silun [2 ]
机构
[1] Tongji Univ, Tongji Hosp, Sch Med, Dept Radiol, 389 Xincun Rd, Shanghai 200065, Peoples R China
[2] YIWEI Med Technol Co Ltd, Room 1001,MAI KE LONG Bldg, Shenzhen 518000, Peoples R China
[3] Nanjing Med Univ, Affiliated Hosp 2, 121 Jiangjiayuan Rd, Nanjing 210011, Peoples R China
基金
中国国家自然科学基金;
关键词
RealNow; RAPID; ischemic core; penumbra; acute ischemic stroke; FINAL INFARCT VOLUME; PREDICT; MAPS; THROMBECTOMY; THRESHOLDS; SELECTION; TIME;
D O I
10.3390/cells11162547
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Purpose: Automated postprocessing packages have been developed for managing acute ischemic stroke (AIS). These packages identify ischemic core and penumbra using either computed tomographic perfusion imaging (CTP) data or magnetic resonance imaging (MRI) data. Measurements of abnormal tissues and treatment decisions derived from different vendors can vary. The purpose of this study is to investigate the agreement of volumetric and decision-making outcomes derived from two software packages. Methods: A total of 594 AIS patients (174 underwent CTP and 420 underwent MRI) were included. Imaging data were accordingly postprocessed by two software packages: RAPID and RealNow. Volumetric outputs were compared between packages by performing intraclass correlation coefficient (ICC), Wilcoxon paired test and Bland-Altman analysis. Concordance of selecting patients eligible for mechanical thrombectomy (MT) was assessed based on neuroimaging criteria proposed in DEFUSE3. Results: In the group with CTP data, mean ischemic core volume (ICV)/penumbral volume (PV) was 14.9/81.1 mL via RAPID and 12.6/83.2 mL via RealNow. Meanwhile, in the MRI group, mean ICV/PV were 52.4/68.4 mL and 48.9/61.6 mL via RAPID and RealNow, respectively. Reliability, which was measured by ICC of ICV and PV in CTP and MRI groups, ranged from 0.87 to 0.99. The bias remained small between measurements (CTP ICV: 0.89 mL, CTP PV: -2 mL, MRI ICV: 3.5 mL and MRI PV: 6.8 mL). In comparison with CTP ICV with follow-up DWI, the ICC was 0.92 and 0.94 for RAPID and Realnow, respectively. The bias remained small between CTP ICV and follow-up DWI measurements (Rapid: -4.65 mL, RealNow: -3.65 mL). Wilcoxon paired test showed no significant difference between measurements. The results of patient triage were concordant in 159/174 cases (91%, ICC: 0.90) for CTP and 400/420 cases (95%, ICC: 0.93) for MRI. Conclusion: The CTP ICV derived from RealNow was more accurate than RAPID. The similarity in volumetric measurement between packages did not necessarily relate to equivalent patient triage. In this study, RealNow showed excellent agreement with RAPID in measuring ICV and PV as well as patient triage.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Characteristics of Misclassified CT Perfusion Ischemic Core in Patients with Acute Ischemic Stroke
    Geuskens, Ralph R. E. G.
    Borst, Jordi
    Lucas, Marit
    Boers, A. M. Merel
    Berkhemer, Olvert A.
    Roos, Yvo B. W. E. M.
    van Walderveen, Marianne A. A.
    Jenniskens, Sjoerd F. M.
    van Zwam, Wim H.
    Dippel, Diederik W. J.
    Majoie, Charles B. L. M.
    Marquering, Henk A.
    PLOS ONE, 2015, 10 (11):
  • [32] Artificial intelligence software for assessing brain ischemic penumbra/core infarction on computed tomography perfusion: A real-world accuracy study
    Li, Zhu-Qin
    Liu, Wu
    Luo, Wei-Liang
    Chen, Su-Qin
    Deng, Yu-Ping
    WORLD JOURNAL OF RADIOLOGY, 2024, 16 (08):
  • [33] Whole-Brain CT Perfusion to Quantify Acute Ischemic Penumbra and Core
    Lin, Longting
    Bivard, Andrew
    Krishnamurthy, Venkatesh
    Levi, Christopher R.
    Parsons, Mark W.
    RADIOLOGY, 2016, 279 (03) : 876 - 887
  • [34] The diagnostic value of susceptibility-weighted imaging for ischemic penumbra in patients with acute ischemic stroke
    Wang, Tianle
    Zhu, Li
    Hu, Chunhong
    Gong, Shenchu
    Jiang, Hongbiao
    Chen, Haitao
    Li, Jia
    TECHNOLOGY AND HEALTH CARE, 2017, 25 : S449 - S457
  • [35] The Application of Software "Rapid Processing of Perfusion and Diffusion" in Acute Ischemic Stroke
    Zhang, Yudi
    Song, Shuang
    Li, Zhenzhong
    Huang, Boyuan
    Geng, Yanlu
    Zhang, Lihong
    BRAIN SCIENCES, 2022, 12 (11)
  • [36] Differences in CT Perfusion Summary Maps for Patients with Acute Ischemic Stroke Generated by 2 Software Packages
    Fahmi, F.
    Marquering, H. A.
    Streekstra, G. J.
    Beenen, L. F. M.
    Velthuis, B. K.
    VanBavel, E.
    Majoie, C. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (11) : 2074 - 2080
  • [37] Mapping the ischemic penumbra and predicting stroke progression in acute ischemic stroke: the overlooked role of susceptibility weighted imaging
    Darwish, Eman A. F.
    Abdelhameed-El-Nouby, Maha
    Geneidy, Eman
    INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [38] Mapping the ischemic penumbra and predicting stroke progression in acute ischemic stroke: the overlooked role of susceptibility weighted imaging
    Eman A. F. Darwish
    Maha Abdelhameed-El-Nouby
    Eman Geneidy
    Insights into Imaging, 11
  • [39] Prognostic Prediction Model for Endovascular Treatment of Acute Anterior Circulation Ischemic Stroke Based on Rapid Processing of PerfusIon and Diffusion Software
    Shen, Yuan
    Xu, Gang
    Shi, Haicun
    Wang, Shufang
    Zhou, Li
    Zhong, Jianguo
    Chen, Mingzhu
    Chen, Zhipeng
    Dong, Zhifeng
    WORLD NEUROSURGERY, 2025, 194
  • [40] The Penumbra System for the Treatment of Acute Ischemic Stroke: Report of Two Cases
    Zhang, Xudong
    Gao, Jun Wei
    Jabbour, Pascal
    TURKISH NEUROSURGERY, 2016, 26 (02) : 306 - 308