Absolute quantitative total-body small-animal SPECT with focusing pinholes

被引:36
作者
Wu, Chao [1 ,2 ,3 ,4 ]
van der Have, Frans [3 ,4 ,5 ,6 ]
Vastenhouw, Brendan [3 ,4 ,5 ,6 ]
Dierckx, Rudi A. J. O. [1 ]
Paans, Anne M. J. [1 ]
Beekman, Freek J. [3 ,4 ,5 ,6 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Grad Sch Drug Explorat, NL-9700 RB Groningen, Netherlands
[3] Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Rudolf Magnus Inst, Utrecht, Netherlands
[5] MILabs BV, Utrecht, Netherlands
[6] Delft Univ Technol, Dept R3, Sect Radiat Detect & Med Imaging, Delft, Netherlands
关键词
Quantification; Quantitative imaging; Small-animal imaging; SPECT; ULTRA-HIGH-RESOLUTION; ATTENUATION CORRECTION; SCATTER CORRECTION; SYSTEM; RECONSTRUCTION; SIMULATION;
D O I
10.1007/s00259-010-1519-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy.
引用
收藏
页码:2127 / 2135
页数:9
相关论文
共 35 条
[1]  
Beekman FJ, 1998, J NUCL MED, V39, P1996
[2]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[3]   Design and simulation of a high-resolution stationary SPECT system for small animals [J].
Beekman, FJ ;
Vastenhouw, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4579-4592
[4]   Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation [J].
Beekman, FJ ;
de Jong, HWAM ;
van Geloven, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :867-877
[5]   The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging [J].
Beekman, Freek ;
van der Have, Frans .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) :151-161
[6]   Effect of cyclosporin A administration on the biodistribution and multipinhole μSPECT imaging of [123I]R91150 in rodent brain [J].
Blanckaert, P. ;
Burvenich, I. ;
Staelens, S. ;
De Bruyne, S. ;
Moerman, L. ;
Wyffels, L. ;
De Vos, F. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (03) :446-453
[7]   Bayesian reconstruction and use of anatomical a Priori information for emission tomography [J].
Bowsher, JE ;
Johnson, VE ;
Turkington, TG ;
Jaszczak, RJ ;
Floyd, CE ;
Coleman, RE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :673-686
[8]   Pixel-based subsets for rapid multi-pinhole SPECT reconstruction [J].
Branderhorst, Woutjan ;
Vastenhouw, Brendan ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :2023-2034
[10]   Multimodality in vivo imaging systems: Twice the power or double the trouble? [J].
Cherry, Simon R. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2006, 8 :35-62