Katsevich-type reconstruction for dual helical cone-beam CT

被引:14
|
作者
Zeng, Li [1 ,2 ]
Zou, Xiaobing [1 ,3 ]
机构
[1] Chongqing Univ, Educ Minist China, Key Lab Optoelect Technol & Syst, ICT Res Ctr, Chongqing 630044, Peoples R China
[2] Chongqing Univ, Coll Math & Phys, Chongqing 630044, Peoples R China
[3] Coll Chongqing Educ, Dept Comp Sci, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Industrial CT; cone beam; dual helical scanning; Katsevich-type algorithm; FILTERED BACKPROJECTION ALGORITHM; EXACT IMAGE-RECONSTRUCTION;
D O I
10.3233/XST-2010-0266
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper is about inspecting large and long object using dual helical cone-beam computed tomography (CT) and Katsevich-type reconstruction algorithm. Conventional cone-beam helical industrial CT imaging is based on the assumption that the entire cross-section of an object is illuminated with x-rays at each view angle. The field of view is limited by the width of planar detector. As an alternative, this paper developed a dual-helical scanning. When scanning at each helix, part of cross-section is covered by x-ray at each view angle. During reconstruction, Katsevich-type algorithm is applied, which does not rebin projection data. The algorithm is approximate, as it applies Hilbert transform on truncated projection. The reconstruction result is better than extended FDK algorithm, especially for large helical pitch.
引用
收藏
页码:353 / 367
页数:15
相关论文
共 50 条
  • [1] Katsevich-type algorithms for variable radius spiral cone-beam CT
    Yu, HY
    Ye, YB
    Wang, G
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 550 - 557
  • [2] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [3] Implementation and optimization of Katsevich algorithm for helical cone-beam CT
    Tang Qibo
    Wei Dongbo
    Li Dan
    Xu Haijun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3945 - 3948
  • [4] The Improvement of Katsevich Reconstruction Algorithm Based on Cone-beam CT
    Wang, Li Fang
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 1148 - 1151
  • [5] Derivation of FBP Reconstruction Algorithm along π-lines Using Katsevich-Type of Proof in Helical CT
    Shi, Daxin
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [6] Numerical studies on Feldkamp-type and Katsevich-type algorithms for cone-beam scanning along nonstandard spirals
    Zhu, JH
    Zhao, SY
    Yu, HY
    Ye, YB
    Lee, SW
    Wang, G
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 558 - 565
  • [7] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [8] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [9] An alternative derivation of Katsevich's cone-beam reconstruction formula
    Chen, GH
    MEDICAL PHYSICS, 2003, 30 (12) : 3217 - 3226
  • [10] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X