摘要
An Au/Cu bimetallic electrode is investigated as a sensor in amperometric flow-through detection in alkaline solutions. Experimental conditions such as detection mode, pH. copper loading and flow-rate on sensitivity and stability are evaluated. Constant-potential detection at 0.550 V or 0.350 V and pulsed detection modes are tested after anion-exchange chromatography of alditols, carbohydrates and amino acids. The detection limits (S/N = 3) of carbohydrates at 0.550 V and 0.350 V ranged between 4.6-9.0 pmol and 1.0-4.0 pmol, respectively. Those of amino acids were 9.0-39 pmol. in pulsed amperometric detection mode, molar sensitivities and detection limits were higher than those obtained in DC mode. Linear dynamic ranges spanned over four (alditols and carbohydrates) and three (amino acids) orders of magnitude. The Au/Cu CME retained 94-96% of its response after several hours operations in flowing streams. As an application, some alditols, carbohydrates and amino acids were determined in soluble coffee and red wine. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 33 条
[1]   ELEMENTARY STEPS OF ELECTROCHEMICAL OXIDATION OF SINGLE-CRYSTAL PLANES OF AU .2. A CHEMICAL AND STRUCTURAL BASIS OF OXIDATION OF THE (111) PLANE [J].
ANGERSTEINKOZLOWSKA, H ;
CONWAY, BE ;
HAMELIN, A ;
STOICOVICIU, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 228 (1-2) :429-453
[2]  
[Anonymous], **DROPPED REF**
[3]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[4]   AN INSITU WEIGHING STUDY OF THE MECHANISM FOR THE FORMATION OF THE ADSORBED OXYGEN MONOLAYER AT A GOLD ELECTRODE [J].
BRUCKENSTEIN, S ;
SHAY, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :131-136
[5]   A STUDY OF THE ELECTROCATALYTIC BEHAVIOR OF GOLD IN BASE USING AC VOLTAMMETRY [J].
BURKE, LD ;
OSULLIVAN, JF .
ELECTROCHIMICA ACTA, 1992, 37 (04) :585-594
[6]   Colloidal gold supported onto glassy carbon substrates as an amperometric sensor for carbohydrates in flow injection and liquid chromatography [J].
Casella, IG ;
Destradis, A ;
Desimoni, E .
ANALYST, 1996, 121 (02) :249-254
[7]   Highly-dispersed copper microparticles on the active gold substrate as an amperometric sensor for glucose [J].
Casella, IG ;
Gatta, M ;
Guascito, MR ;
Cataldi, TRI .
ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) :63-71
[8]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[9]   Development of a carbon composite electrode made from polyethylene and graphite powder modified with copper(I) oxide [J].
Cataldi, TRI ;
Centonze, D .
ANALYTICA CHIMICA ACTA, 1996, 326 (1-3) :107-115
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SULFUR-CONTAINING AMINO-ACIDS AND RELATED-COMPOUNDS WITH AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE [J].
COX, JA ;
DABEKZLOTORZYNSKA, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01) :226-232