Standardizing Dimensionless Cutometer Parameters to Determine In Vivo Elasticity of Human Skin

被引:18
作者
Abbas, Darren B. [1 ]
Lavin, Christopher, V [1 ]
Fahy, Evan J. [1 ]
Griffin, Michelle [1 ]
Guardino, Nicholas [1 ]
King, Megan [1 ]
Chen, Kellen [1 ]
Lorenz, P. Hermann [1 ]
Gurtner, Geoffrey C. [1 ]
Longaker, Michael T. [1 ,2 ]
Momeni, Arash [1 ]
Wan, Derrick C. [1 ]
机构
[1] Stanford Univ, Sch Med, Hagey Lab Pediat Regenerat Med, Dept Surg, 257 Campus Dr West, Stanford, CA 94305 USA
[2] Stanford Univ, Inst Stem Cell Biol & Regenerat Med, Sch Med, Stanford, CA 94305 USA
关键词
cutometer; skin elasticity; skin elasticity measurement; in vivo skin elasticity; viscoelasticity; skin fibrosis; SCAR ASSESSMENT SCALE; HYPERTROPHIC SCAR; QUANTITATIVE MEASUREMENT; MPA; 580; RELIABILITY; VISCOELASTICITY; PATIENT; QUANTIFICATION; VALIDATION; FIBROSIS;
D O I
10.1089/wound.2021.0082
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Objective: Skin fibrosis places an enormous burden on patients and society, but disagreement exists over methods to quantify severity of skin scarring. A suction cutometer measures skin elasticity in vivo, but it has not been widely adopted because of inconsistency in data produced. We investigated variability of several dimensionless parameters generated by the cutometer to improve their precision and accuracy. Approach: Twenty adult human subjects underwent suction cutometer measurement of normal skin (NS) and fibrotic scars (FS). Using Mode 1, each subject underwent five trials with each trial containing four curves. R0/2/5/6/7 and Q1/2/3 data were collected. Analyses were performed on these calculated parameters. Results: R0/2/5/6/7 and Q1/2 parameters from curves 1 to 4 demonstrated significant differences, whereas these same parameters were not significantly different when only using curves 2-4. Individual analysis of all parameters between curve 1 and every subsequent curve was statistically significant for R0, R2, R5, R6, R7, Q1, and Q2. No differences were appreciated for parameter Q3. Comparison between NS and FS were significantly different for parameters R5, Q1, and Q3. Innovation: Our study is the first demonstration of accurate comparison between NS and FS using the dimensionless parameters of a suction cutometer. Conclusions: Measured parameters from the first curve of each trial were significantly different from subsequent curves for both NS and FS. Precision and reproducibility of data from dimensionless parameters can therefore be improved by removing the first curve. R5, Q1, and Q3 parameters differentiated NS as more elastic than FS.
引用
收藏
页码:297 / 310
页数:14
相关论文
共 44 条
[1]   Analysis of Frequency of Use of Different Scar Assessment Scales Based on the Scar Condition and Treatment Method [J].
Bae, Seong Hwan ;
Bae, Yong Chan .
ARCHIVES OF PLASTIC SURGERY-APS, 2014, 41 (02) :111-115
[2]   The effect of probe placement on inter-trial variability when using the Cutometer MPA 580 [J].
Bonaparte, James P. ;
Chung, Jeffson .
Journal of Medical Engineering and Technology, 2014, 38 (02) :85-89
[3]   The effect of probe to skin contact force on Cutometer MPA 580 measurements [J].
Bonaparte, J.P. (DrJames.Bonaparte@gmail.com), 1600, Informa Healthcare (37) :208-212
[4]  
Borrelli MR, 2020, J AM COLL SURGEONS, V231, pE186
[5]   Burn Scar Evaluation Using the Cutometer® MPA 580 in Comparison to "Patient and Observer Scar Assessment Scale" and "Vancouver Scar Scale" [J].
Busche, Marc Nicolai ;
Thraen, Alice-Caroline Johanna ;
Gohritz, Andreas ;
Rennekampff, Hans-Oliver ;
Vogt, Peter Maria .
JOURNAL OF BURN CARE & RESEARCH, 2018, 39 (04) :516-526
[6]   A Novel Tool for the Objective Measurement of Neck Fibrosis: Validation in Clinical Practice [J].
Chin, Christopher J. ;
Franklin, Jason H. ;
Turner, Benjamin ;
Moukarbel, Roger V. ;
Chandarana, Shamir ;
Fung, Kevin ;
Yoo, John ;
Doyle, Philip C. .
JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2012, 41 (05) :320-326
[7]   Reliability of the Patient and Observer Scar Assessment Scale in Evaluating Linear Scars after Thyroidectomy [J].
Chung, Jae-Ho ;
Kwon, Sang-Ho ;
Kim, Ki-Jae ;
Lee, Jae-Min ;
Yoon, Jeong-Min ;
Cheon, Jeong-Hyun ;
Yoon, Eul-Sik ;
Park, Seung-Ha .
ADVANCES IN SKIN & WOUND CARE, 2021, 34 (06)
[8]   Novel Ideas: The Increased Skin Viscoelasticity - A Possible New Fifth Sign for the Very Early Diagnosis of Systemic Sclerosis [J].
Dobrev, Hristo .
CURRENT RHEUMATOLOGY REVIEWS, 2013, 9 (04) :261-267
[9]   Skin elasticity meter or subjective evaluation in scars: a reliability assessment [J].
Draaijers, LJ ;
Botman, YAM ;
Tempelman, FRH ;
Kreis, RW ;
Middelkoop, E ;
van Zuijlen, PPM .
BURNS, 2004, 30 (02) :109-114
[10]   Quantification of cutaneous sclerosis with a skin elasticity meter in patients with generalized scleroderma [J].
Enomoto, DNH ;
Mekkes, JR ;
Bossuyt, PMM ;
Hoekzema, R ;
Bos, JD .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1996, 35 (03) :381-387