Non-Contrast Perfusion Detection with ARFI Variance of Acceleration (VoA) Imaging: Phantom and In Vivo Results

被引:0
|
作者
Varadarajan, Ramya [1 ]
Torres, Gabriela [1 ]
Hossain, Md. Murad [1 ]
Gallippi, Caterina M. [1 ]
机构
[1] Univ North Carolina & North Carolina State Univ, Joint Dept Biomed Engn, Chapel Hill, NC 27514 USA
来源
2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2019年
关键词
ARFI imaging; perfusion detection; non-contrast imaging; IMPACT; TRACKING; VELOCITY; DISEASE;
D O I
10.1109/ultsym.2019.8926231
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Low blood SNR makes detecting small vessels, measuring slow flow rates, and assessing blood perfusion without contrast administration challenging. A potential approach is to use Variance of Acceleration (VoA) imaging, which has been demonstrated previously in humans in vivo for monitoring subcutaneous bleeding and delineating intraplaque hemorrhage. We hypothesize that, without the addition of contrast agents, VoA can detect slow flow in small vessels for perfusion assessment. Experiments were performed on an ATS 700-D 527 calibrated flow phantom (vessel diameter of 1 mm, flow rates of 0-53 cm/s) and in the surgically exteriorized right kidneys of 3 pigs (2M/1F, mean body weight of 74.4 +/- 9.3 kg) at baseline and after inducing ischemia. In the phantom, logVoA increased in the vessel with increasing flow rate, and it remained constant in the background. LogVoA values were higher in the background with versus without the ARF excitation. Similarly, logVoA values were higher in the vessel, particularly for flow rates < 12 cm/s, with versus without ARF excitation. Vessel CNR by logVoA was higher with versus without ARF excitation for flow rates < 12 cm/s, and CNR by logVoA was greater than CNR by power Doppler for all flow rates. Additionally, logVoA was statistically significantly greater at baseline than ischemia in all three in vivo pig kidneys. Finally, logVoA delineates a 1.25 mm-diameter vessel in a pig renal cortex in vivo, while power Doppler does not. These results suggest that logVoA could support contrast-free detection of slow blood flow in small vessels and in vivo perfusion assessment.
引用
收藏
页码:2252 / 2255
页数:4
相关论文
共 50 条
  • [31] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Kanatani, Risa
    Shirasaka, Takashi
    Kojima, Tsukasa
    Kato, Toyoyuki
    Kawakubo, Masateru
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [32] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Risa Kanatani
    Takashi Shirasaka
    Tsukasa Kojima
    Toyoyuki Kato
    Masateru Kawakubo
    European Radiology Experimental, 5
  • [33] Contrast vs non-contrast enhanced microvascular imaging using acoustic sub-aperture processing (ASAP) : in vivo demonstration
    Leow, Chee Hau
    Braga, Marta
    Bush, Nigel L.
    Stanziola, Antonio
    Shah, Anant
    Hernandez-Gil, Javier
    Long, Nicholas J.
    Aboagye, Eric O.
    Bamber, Jeffrey C.
    Tang, Meng-Xing
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [34] Detection of upper extremity deep vein thrombosis by magnetic resonance non-contrast thrombus imaging
    van Dam, Lisette F.
    Dronkers, Charlotte E. A.
    Gautam, Gargi
    Eckerbom, Asa
    Ghanima, Waleed
    Gleditsch, Jostein
    van Haren, Guido R.
    von Heijne, Anders
    Huisman, Menno, V
    Stoger, J. Lauran
    Westerlund, Eli
    Kroft, Lucia J. M.
    Klok, Frederikus A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2021, 19 (08) : 1973 - 1980
  • [35] Detection of acute and chronic arterial thrombi in vivo: A comparative study of non-contrast enhanced magnetic resonance imaging (MRI) and fibrin-targeted contrast enhancing MR agent
    Sirol, M
    Fuster, V
    Badimon, JJ
    Viles-Gonzalez, J
    Fallon, JT
    Fayad, ZA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 297A - 297A
  • [36] BEST IN PHYSICS (IMAGING): Improvement of Infarction Core Detectability in Cerebral CT Perfusion Imaging by Leveraging High Quality Non-Contrast Head CT
    Harvey, E.
    Li, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E346 - E346
  • [37] Editorial for "Feasibility of Velocity-Selective Arterial Spin Labelling in Breast Cancer Patients for Non-contrast Enhanced Perfusion Imaging"
    Nogueira, Luisa
    Nunes, Rita Gouveia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) : 1292 - 1293
  • [38] Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation
    Zhang, Ke
    Triphan, Simon M. F.
    Wielpuetz, Mark O.
    Ziener, Christian H.
    Ladd, Mark E.
    Schlemmer, Heinz-Peter
    Kauczor, Hans-Ulrich
    Sedlaczek, Oliver
    Kurz, Felix T.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2025, 35 (01): : 87 - 97
  • [39] Detection of bone erosion in early rheumatoid arthritis: ultrasonography and conventional radiography versus non-contrast magnetic resonance imaging
    Maryam Rahmani
    Hosein Chegini
    Seyed Reza Najafizadeh
    Mohammad Azimi
    Peiman Habibollahi
    Madjid Shakiba
    Clinical Rheumatology, 2010, 29 : 883 - 891
  • [40] Detection of bone erosion in early rheumatoid arthritis: ultrasonography and conventional radiography versus non-contrast magnetic resonance imaging
    Rahmani, Maryam
    Chegini, Hosein
    Najafizadeh, Seyed Reza
    Azimi, Mohammad
    Habibollahi, Peiman
    Shakiba, Madjid
    CLINICAL RHEUMATOLOGY, 2010, 29 (08) : 883 - 891